☣️ UN 1020 • CLASS 2

UN 1020 — Chloropentafluoroethane

Placard: Non-Flammable Gas. ERG Guide 126. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 1020 Quick Details

UN 1020
Product name: Chloropentafluoroethane
DOT Class: 2
Placard type: Non-Flammable Gas
ERG Guide: 126 (check current ERG)
Initial isolation: ERG 126: Initial isolation 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions

Common Hazards of UN 1020

  • Some may burn but none ignite readily.
  • Containers may explode when heated.
  • Ruptured cylinders may rocket.
  • Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.
  • Vapors from liquefied gas are initially heavier than air and spread along ground.
  • Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite.
  • Fire may produce irritating, corrosive and/or toxic gases.

Chemical Identity & Physical Properties

Also known asCFC-115Refrigerant 115R-115Genetron 115PentafluorochloroethaneMonochloropentafluoroethane
CAS Number76-15-3
AppearanceColorless, odorless liquefied gas. Shipped as a liquefied compressed gas under pressure.
Flash PointNot applicable (non-flammable gas)
Boiling Point-39C (-38F)
Vapor Density5.2 (heavier than air)
Water ReactivityNo significant reaction with water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1020

Extinguishing Media

CO2, dry chemical, water spray for cooling containers; foam not typically required for non-flammable gas

PPE Requirements

⚠️ Level B minimum; SCBA required in confined spaces or high concentrations; cold-resistant gloves for handling cylinders to prevent frostbite

Isolation & Evacuation

ERG 126: Initial isolation 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 126).

First Actions for a UN 1020 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Many gases are heavier than air and will spread along the ground and collect in low or confined areas
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
  • Consider initial downwind evacuation for at least 500 meters (1/3 mile).
Advertisement

📋 Copy & Share Field Card

UN 1020 — Chloropentafluoroethane
HAZMAT RADIO NOTE — UN 1020 Product: Chloropentafluoroethane Class 2 / Non-Flammable Gas / ERG 126 PPE: Level B minimum; SCBA required in confined spaces or high concentrations; cold-resistant gloves for handling cylinders to prevent frostbite ISOLATION: ERG 126: Initial isolation 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1020 — Chloropentafluoroethane Class: 2 | Placard: Non-Flammable Gas | ERG Guide: 126 Appearance: Colorless, odorless liquefied gas. Shipped as a liquefied compressed gas under pressure. Water Reactivity: No significant reaction with water Extinguishing: CO2, dry chemical, water spray for cooling containers; foam not typically required for non-flammable gas PPE: Level B minimum; SCBA required in confined spaces or high concentrations; cold-resistant gloves for handling cylinders to prevent frostbite Isolation: ERG 126: Initial isolation 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions — Key Hazards — • Some may burn but none ignite readily. • Containers may explode when heated. • Ruptured cylinders may rocket. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Many gases are heavier than air and will spread along the ground and collect in low or confined areas SOURCE: allfirefighter.com/hazmat/un/1020 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN1020 Chloropentafluoroethane Cls2 ERG126 | allfirefighter.com/hazmat/un/1020SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/1020

Related UN Numbers in Class 2

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1020

Some may burn but none ignite readily. Containers may explode when heated. Ruptured cylinders may rocket. Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas. Vapors from liquefied gas are initially heavier than air and spread along ground. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire may produce irritating, corrosive and/or toxic gases.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum; SCBA required in confined spaces or high concentrations; cold-resistant gloves for handling cylinders to prevent frostbite

Water reactivity: No significant reaction with water. Recommended extinguishing: CO2, dry chemical, water spray for cooling containers; foam not typically required for non-flammable gas.

ERG Guide 126 recommendation: ERG 126: Initial isolation 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 126 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.