☣️ UN 1162 • CLASS 3
UN 1162 — Dimethyldichlorosilane
Placard: Flammable. ERG Guide 155. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
UN 1162 Quick Details
UN 1162
Product name: Dimethyldichlorosilane
DOT Class: 3
Placard type: Flammable
ERG Guide: 155 (check current ERG)
Initial isolation: ERG 155: Isolate spill 50m in all directions. For large spill, isolate 800m downwind. Evacuate immediate area if fire involved.
Common Hazards of UN 1162
- HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
- Vapors form explosive mixtures with air: indoors, outdoors and sewers explosion hazards.
- Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
- Vapors may travel to source of ignition and flash back.
- Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
- Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff.
- Corrosives in contact with metals may evolve flammable hydrogen gas.
- Containers may explode when heated or if contaminated with water.
Chemical Identity & Physical Properties
| Also known as | DichlorodimethylsilaneDimethyldichlorosilaneDMDCSSilane, dichlorodimethyl- |
| CAS Number | 75-78-5 |
| Appearance | Colorless to pale yellow fuming liquid with a pungent, irritating, hydrochloric acid-like odor. Reacts violently with water, producing dense white fumes of hydrochloric acid. |
| Flash Point | -16C (3F) |
| Boiling Point | 70C (158F) |
| Vapor Density | 4.4 (heavier than air) |
| Water Reactivity | Reacts violently with water, producing hydrochloric acid and heat. DO NOT USE WATER directly on material. |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Fireground Response Guidance — UN 1162
Extinguishing Media
Dry chemical, CO2, or dry sand only. Do NOT use water or foam.
PPE Requirements
⚠️ Level B minimum with SCBA required. Full chemical-resistant suit for spill response. Butyl rubber or Viton gloves recommended.
Isolation & Evacuation
ERG 155: Isolate spill 50m in all directions. For large spill, isolate 800m downwind. Evacuate immediate area if fire involved.
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 155).
First Actions for a UN 1162 Incident
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
- For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
- For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share Field Card
UN 1162 — DimethyldichlorosilaneHAZMAT RADIO NOTE — UN 1162
Product: Dimethyldichlorosilane
Class 3 / Flammable / ERG 155
PPE: Level B minimum with SCBA required. Full chemical-resistant suit for spill response. Butyl rubber or Viton gloves recommended.
ISOLATION: ERG 155: Isolate spill 50m in all directions. For large spill, isolate 800m downwind. Evacuate immediate area if fire involved.
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 1162 — Dimethyldichlorosilane
Class: 3 | Placard: Flammable | ERG Guide: 155
Appearance: Colorless to pale yellow fuming liquid with a pungent, irritating, hydrochloric acid-like odor. Reacts violently with water, producing dense white fumes of hydrochloric acid.
Water Reactivity: Reacts violently with water, producing hydrochloric acid and heat. DO NOT USE WATER directly on material.
Extinguishing: Dry chemical, CO2, or dry sand only. Do NOT use water or foam.
PPE: Level B minimum with SCBA required. Full chemical-resistant suit for spill response. Butyl rubber or Viton gloves recommended.
Isolation: ERG 155: Isolate spill 50m in all directions. For large spill, isolate 800m downwind. Evacuate immediate area if fire involved.
— Key Hazards —
• HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
• Vapors form explosive mixtures with air: indoors, outdoors and sewers explosion hazards.
• Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Ventilate closed spaces before entering, but only if properly trained and equipped.
SOURCE: allfirefighter.com/hazmat/un/1162 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN1162 Dimethyldichlorosilane Cls3 ERG155 | ERG 155: Isolate spill 50m in all directions. For large spill, isolate 800m down | allfirefighter.com/hazmat/un/1162SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions.
Page: https://allfirefighter.com/hazmat/un/1162
Advertisement
Frequently Asked Questions about UN 1162
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors form explosive mixtures with air: indoors, outdoors and sewers explosion hazards. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapors may travel to source of ignition and flash back. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Substance will react with water (some violently) releasing flammable, toxic or corrosive gases and runoff. Corrosives in contact with metals may evolve flammable hydrogen gas. Containers may explode when heated or if contaminated with water.
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level B minimum with SCBA required. Full chemical-resistant suit for spill response. Butyl rubber or Viton gloves recommended.
Water reactivity: Reacts violently with water, producing hydrochloric acid and heat. DO NOT USE WATER directly on material.. Recommended extinguishing: Dry chemical, CO2, or dry sand only. Do NOT use water or foam..
ERG Guide 155 recommendation: ERG 155: Isolate spill 50m in all directions. For large spill, isolate 800m downwind. Evacuate immediate area if fire involved.
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 155 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles.
This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.