☣️ UN 1213 • CLASS 3

UN 1213 — Isobutyl acetate

Placard: Flammable. ERG Guide 129. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 1213 Quick Details

UN 1213
Product name: Isobutyl acetate
DOT Class: 3
Placard type: Flammable
ERG Guide: 129 (check current ERG)
Initial isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m and evacuate 800m downwind if fire

Common Hazards of UN 1213

  • HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
  • Vapors may form explosive mixtures with air.
  • Vapors may travel to source of ignition and flash back.
  • Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
  • Vapor explosion hazard indoors, outdoors or in sewers.
  • Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
  • Runoff to sewer may create fire or explosion hazard.
  • Containers may explode when heated.

Chemical Identity & Physical Properties

Also known as2-Methylpropyl acetateAcetic acid isobutyl ester2-Methyl-1-propyl acetateIsobutyl ethanoate
CAS Number110-19-0
AppearanceColorless liquid with a fruity, banana-like odor. Highly volatile and flammable at room temperature.
Flash Point18°C (64°F)
Boiling Point116-118°C (241-244°F)
Vapor Density4.0 (heavier than air)
Water ReactivityNo significant reaction; immiscible with water, floats on surface
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1213

Extinguishing Media

AFFF, alcohol-resistant foam, CO2, dry chemical; water spray for cooling only

PPE Requirements

⚠️ Level B minimum with SCBA; chemical-resistant gloves and suit; avoid all ignition sources

Isolation & Evacuation

ERG 129: Small spill isolate 30m all directions; large spill isolate 150m and evacuate 800m downwind if fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 129).

First Actions for a UN 1213 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
  • Consider initial downwind evacuation for at least 300 meters (1000 feet).
Advertisement

📋 Copy & Share Field Card

UN 1213 — Isobutyl acetate
HAZMAT RADIO NOTE — UN 1213 Product: Isobutyl acetate Class 3 / Flammable / ERG 129 PPE: Level B minimum with SCBA; chemical-resistant gloves and suit; avoid all ignition sources ISOLATION: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m and evacuate 800m downwind if fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1213 — Isobutyl acetate Class: 3 | Placard: Flammable | ERG Guide: 129 Appearance: Colorless liquid with a fruity, banana-like odor. Highly volatile and flammable at room temperature. Water Reactivity: No significant reaction; immiscible with water, floats on surface Extinguishing: AFFF, alcohol-resistant foam, CO2, dry chemical; water spray for cooling only PPE: Level B minimum with SCBA; chemical-resistant gloves and suit; avoid all ignition sources Isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m and evacuate 800m downwind if fire — Key Hazards — • HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. • Vapors may form explosive mixtures with air. • Vapors may travel to source of ignition and flash back. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/1213 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN1213 Isobutyl acetate Cls3 ERG129 | ERG 129: Small spill isolate 30m all directions; large spill isolate 150m and ev | allfirefighter.com/hazmat/un/1213SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/1213

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1213

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum with SCBA; chemical-resistant gloves and suit; avoid all ignition sources

Water reactivity: No significant reaction; immiscible with water, floats on surface. Recommended extinguishing: AFFF, alcohol-resistant foam, CO2, dry chemical; water spray for cooling only.

ERG Guide 129 recommendation: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m and evacuate 800m downwind if fire

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 129 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.