☣️ UN 1858 • CLASS 2
UN 1858 — Hexafluoropropylene, compressed
Placard: Non-Flammable Gas. ERG Guide 126. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
UN 1858 Quick Details
UN 1858
Product name: Hexafluoropropylene, compressed
DOT Class: 2
Placard type: Non-Flammable Gas
ERG Guide: 126 (check current ERG)
Initial isolation: ERG 126: Isolate 100m in all directions initially. If tank/rail car involved in fire, isolate 800m in all directions and evacuate.
Common Hazards of UN 1858
- Some may burn but none ignite readily.
- Containers may explode when heated.
- Ruptured cylinders may rocket.
- Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas.
- Vapors from liquefied gas are initially heavier than air and spread along ground.
- Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite.
- Fire may produce irritating, corrosive and/or toxic gases.
Chemical Identity & Physical Properties
| Also known as | HFPPerfluoropropylenePerfluoropropene1,1,2,3,3,3-Hexafluoro-1-propeneR-1216 |
| CAS Number | 116-15-4 |
| Appearance | Colorless, odorless compressed gas. Liquefied under pressure. Non-flammable but supports combustion of other materials. |
| Flash Point | Not applicable (non-flammable gas) |
| Boiling Point | -29C (-20F) |
| Vapor Density | 5.2 (heavier than air) |
| Water Reactivity | No significant reaction with water. Hydrolyzes slowly in presence of moisture. |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Fireground Response Guidance — UN 1858
Extinguishing Media
Water spray for cooling containers, CO2, dry chemical. Not flammable but extinguish nearby fires.
PPE Requirements
⚠️ Level B minimum; SCBA required in enclosed spaces. Full-face respirator, chemical-resistant gloves and suit. Protect from frostbite hazard.
Isolation & Evacuation
ERG 126: Isolate 100m in all directions initially. If tank/rail car involved in fire, isolate 800m in all directions and evacuate.
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 126).
First Actions for a UN 1858 Incident
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Many gases are heavier than air and will spread along the ground and collect in low or confined areas
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
- Consider initial downwind evacuation for at least 500 meters (1/3 mile).
Advertisement
📋 Copy & Share Field Card
UN 1858 — Hexafluoropropylene, compressedHAZMAT RADIO NOTE — UN 1858
Product: Hexafluoropropylene, compressed
Class 2 / Non-Flammable Gas / ERG 126
PPE: Level B minimum; SCBA required in enclosed spaces. Full-face respirator, chemical-resistant gloves and suit. Protect from frostbite hazard.
ISOLATION: ERG 126: Isolate 100m in all directions initially. If tank/rail car involved in fire, isolate 800m in all directions and evacuate.
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 1858 — Hexafluoropropylene, compressed
Class: 2 | Placard: Non-Flammable Gas | ERG Guide: 126
Appearance: Colorless, odorless compressed gas. Liquefied under pressure. Non-flammable but supports combustion of other materials.
Water Reactivity: No significant reaction with water. Hydrolyzes slowly in presence of moisture.
Extinguishing: Water spray for cooling containers, CO2, dry chemical. Not flammable but extinguish nearby fires.
PPE: Level B minimum; SCBA required in enclosed spaces. Full-face respirator, chemical-resistant gloves and suit. Protect from frostbite hazard.
Isolation: ERG 126: Isolate 100m in all directions initially. If tank/rail car involved in fire, isolate 800m in all directions and evacuate.
— Key Hazards —
• Some may burn but none ignite readily.
• Containers may explode when heated.
• Ruptured cylinders may rocket.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Many gases are heavier than air and will spread along the ground and collect in low or confined areas
SOURCE: allfirefighter.com/hazmat/un/1858 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN1858 Hexafluoropropylene, compressed Cls2 ERG126 | allfirefighter.com/hazmat/un/1858SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions.
Page: https://allfirefighter.com/hazmat/un/1858
Advertisement
Frequently Asked Questions about UN 1858
Some may burn but none ignite readily. Containers may explode when heated. Ruptured cylinders may rocket. Vapors may cause dizziness or asphyxiation without warning, especially when in closed or confined areas. Vapors from liquefied gas are initially heavier than air and spread along ground. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire may produce irritating, corrosive and/or toxic gases.
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level B minimum; SCBA required in enclosed spaces. Full-face respirator, chemical-resistant gloves and suit. Protect from frostbite hazard.
Water reactivity: No significant reaction with water. Hydrolyzes slowly in presence of moisture.. Recommended extinguishing: Water spray for cooling containers, CO2, dry chemical. Not flammable but extinguish nearby fires..
ERG Guide 126 recommendation: ERG 126: Isolate 100m in all directions initially. If tank/rail car involved in fire, isolate 800m in all directions and evacuate.
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 126 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles.
This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.