☣️ UN 2195 • CLASS 2
Tellurium hexafluoride
Placard: Toxic Gas. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 2195
Class: 2
Placard type: Toxic Gas
ERG: Guide 125 (check current ERG)
Isolation: ERG 125: initially isolate 100m in all directions; protective action distance up to 800m downwind for large spills during daytime
Chemical & Response Details
| Also known as | Tellurium(VI) fluorideTellurium fluorideTeF6Hexafluorotellurium |
| CAS Number | 7783-80-4 |
| Appearance | Colorless gas with a repulsive odor. Shipped as a liquefied compressed gas under pressure at room temperature. |
| Flash Point | Not applicable (non-flammable gas) |
| Boiling Point | -38.9°C (-38°F) |
| Vapor Density | 7.2 (much heavier than air) |
| Water Reactivity | Reacts slowly with water forming hydrofluoric acid and tellurium dioxide; corrosive products formed |
| Extinguishing | Not applicable for fire suppression; dry chemical or CO2 if nearby fire; evacuate area for gas leak |
| PPE | ⚠️ Level A required for concentrated releases; full-face SCBA, chemical-resistant suit; avoid any skin/eye contact |
| Isolation | ERG 125: initially isolate 100m in all directions; protective action distance up to 800m downwind for large spills during daytime |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
- TOXIC and/or CORROSIVE; may be fatal if inhaled, ingested or absorbed through skin.
- Vapors are extremely irritating and corrosive.
- Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite.
- Fire will produce irritating, corrosive and/or toxic gases.
- Runoff from fire control or dilution water may cause environmental contamination.
- Some may burn but none ignite readily.
- Vapors from liquefied gas are initially heavier than air and spread along ground.
- Some of these materials may react violently with water.
First actions (field-minded)
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Many gases are heavier than air and will spread along the ground and collect in low or confined areas
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area for at least 100 meters (330 feet) in all directions.
- For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
- For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 2195 — Tellurium hexafluoride HAZMAT RADIO NOTE — UN 2195
Product: Tellurium hexafluoride
Class 2 / Toxic Gas / ERG 125
PPE: Level A required for concentrated releases; full-face SCBA, chemical-resistant suit; avoid any skin/eye contact
ISOLATION: ERG 125: initially isolate 100m in all directions; protective action distance up to 800m downwind for large spills during daytime
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 2195 — Tellurium hexafluoride
Class: 2 | Placard: Toxic Gas | ERG Guide: 125
Appearance: Colorless gas with a repulsive odor. Shipped as a liquefied compressed gas under pressure at room temperature.
Water Reactivity: Reacts slowly with water forming hydrofluoric acid and tellurium dioxide; corrosive products formed
Extinguishing: Not applicable for fire suppression; dry chemical or CO2 if nearby fire; evacuate area for gas leak
PPE: Level A required for concentrated releases; full-face SCBA, chemical-resistant suit; avoid any skin/eye contact
Isolation: ERG 125: initially isolate 100m in all directions; protective action distance up to 800m downwind for large spills during daytime
— Key Hazards —
• TOXIC and/or CORROSIVE; may be fatal if inhaled, ingested or absorbed through skin.
• Vapors are extremely irritating and corrosive.
• Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Many gases are heavier than air and will spread along the ground and collect in low or confined areas
SOURCE: allfirefighter.com/hazmat/un/2195 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN2195 Tellurium hexafluoride Cls2 ERG125 | ERG 125: initially isolate 100m in all directions; protective action distance up | allfirefighter.com/hazmat/un/2195SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2195
Advertisement
FAQ
TOXIC and/or CORROSIVE; may be fatal if inhaled, ingested or absorbed through skin. Vapors are extremely irritating and corrosive. Contact with gas or liquefied gas may cause burns, severe injury and/or frostbite. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may cause environmental contamination. Some may burn but none ignite readily. Vapors from liquefied gas are initially heavier than air and spread along ground. Some of these materials may react violently with water.
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level A required for concentrated releases; full-face SCBA, chemical-resistant suit; avoid any skin/eye contact
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 125 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.