☣️ UN 2247 • CLASS 3
n-Decane
Placard: Flammable. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 2247
Class: 3
Placard type: Flammable
ERG: Guide 128 (check current ERG)
Isolation: ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions
Chemical & Response Details
| Also known as | decanen-decanedecyl hydridenormal decane |
| CAS Number | 124-18-5 |
| Appearance | Colorless liquid with a mild gasoline-like or kerosene-like odor. Liquid at room temperature with low viscosity. |
| Flash Point | 46C (115F) |
| Boiling Point | 174C (345F) |
| Vapor Density | 4.9 (heavier than air) |
| Water Reactivity | Insoluble in water; floats on water surface. No significant reaction with water. |
| Extinguishing | AFFF foam, alcohol-resistant foam, CO2, dry chemical, water spray for cooling |
| PPE | ⚠️ Level B minimum for spill response; SCBA and chemical-protective clothing for fire situations or confined spaces |
| Isolation | ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
- HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
- Vapors may form explosive mixtures with air.
- Vapors may travel to source of ignition and flash back.
- Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
- Vapor explosion hazard indoors, outdoors or in sewers.
- Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
- Runoff to sewer may create fire or explosion hazard.
- Containers may explode when heated.
First actions (field-minded)
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
- Consider initial downwind evacuation for at least 300 meters (1000 feet).
Advertisement
📋 Copy & Share
UN 2247 — n-Decane HAZMAT RADIO NOTE — UN 2247
Product: n-Decane
Class 3 / Flammable / ERG 128
PPE: Level B minimum for spill response; SCBA and chemical-protective clothing for fire situations or confined spaces
ISOLATION: ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 2247 — n-Decane
Class: 3 | Placard: Flammable | ERG Guide: 128
Appearance: Colorless liquid with a mild gasoline-like or kerosene-like odor. Liquid at room temperature with low viscosity.
Water Reactivity: Insoluble in water; floats on water surface. No significant reaction with water.
Extinguishing: AFFF foam, alcohol-resistant foam, CO2, dry chemical, water spray for cooling
PPE: Level B minimum for spill response; SCBA and chemical-protective clothing for fire situations or confined spaces
Isolation: ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions
— Key Hazards —
• HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
• Vapors may form explosive mixtures with air.
• Vapors may travel to source of ignition and flash back.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Ventilate closed spaces before entering, but only if properly trained and equipped.
SOURCE: allfirefighter.com/hazmat/un/2247 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN2247 n-Decane Cls3 ERG128 | ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m | allfirefighter.com/hazmat/un/2247SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2247
Advertisement
FAQ
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated.
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level B minimum for spill response; SCBA and chemical-protective clothing for fire situations or confined spaces
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 128 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.