☣️ UN 2247 • CLASS 3

UN 2247 — n-Decane

Placard: Flammable. ERG Guide 128. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2247 is n-Decane, a flammable liquid assigned to ERG Guide 128. Vapors can travel to ignition sources and flash back, especially in drains or confined spaces.

Hazard overview: FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Response guidance: For a UN 2247 incident, verify the product with shipping papers, container markings, SDS and ERG Guide 128. Establish incident command, isolate the area, stay upwind, control ignition or incompatibility hazards, prevent runoff, dust or vapor spread and base entry/fire-control actions on monitoring and local SOP.

Firefighter training notes: Training for UN 2247 should emphasize vapor travel, sewer flashback, foam selection, container cooling, ignition control and runoff containment. Use ERG 128, SDS and local SOP.

Regulatory context: n-Decane is regulated as a hazardous material for transportation and emergency response purposes. Storage, workplace exposure, emergency planning, spill reporting, waste handling and environmental requirements vary by exact product, concentration, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, container markings and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: n-Decane should be stored in approved flammable-liquid containers with ventilation, bonding/grounding where required, spill containment and separation from heat, ignition sources, oxidizers and incompatible materials.

Advertisement

UN 2247 Quick Details

UN 2247
Product name: n-Decane
DOT Class: 3
Placard type: Flammable
ERG Guide: 128 (check current ERG)
Initial isolation: ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions

Common Hazards of UN 2247

  • FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.
  • Runoff to sewers may create fire or explosion hazards.
  • Containers may rupture or explode when heated.
  • Fire may produce irritating and/or toxic smoke.
  • Specific solvent, hydrocarbon, ketone, ester or amine exposure hazards should be confirmed from SDS.

Chemical Identity & Physical Properties

Colorless liquid with a mild gasoline-like or kerosene-like odor. Liquid at room temperature with low viscosity.

Also known asdecanen-decanedecyl hydridenormal decane
CAS Number124-18-5
AppearanceColorless liquid with a mild gasoline-like or kerosene-like odor. Liquid at room temperature with low viscosity.
Flash Point46C (115F)
Boiling Point174C (345F)
Vapor Density4.9 (heavier than air)
Water ReactivityInsoluble in water; floats on water surface. No significant reaction with water.
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2247

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

PPE Requirements

⚠️ Level B minimum for spill response; SCBA and chemical-protective clothing for fire situations or confined spaces

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection, flame-resistant protection as appropriate and PPE selected from SDS.

Isolation & Evacuation

ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 128).

First Actions for a UN 2247 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid breathing vapors, dust, mist, smoke or fumes and avoid skin or eye contact.
  • Eliminate ignition sources if safe and keep vapors and runoff out of drains, sewers, basements and low areas.
  • Do not touch damaged containers or spilled material unless properly trained and wearing appropriate protective equipment.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the spill or release area and expand the perimeter for fire involvement, vapor spread, dust generation, water reaction or unknown product identity.
  • Use ERG Guide 128, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 2247 — n-Decane
HAZMAT RADIO NOTE — UN 2247 Product: n-Decane Class 3 / Flammable / ERG 128 PPE: Level B minimum for spill response; SCBA and chemical-protective clothing for fire situations or confined spaces ISOLATION: ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2247 — n-Decane Class: 3 | Placard: Flammable | ERG Guide: 128 Appearance: Colorless liquid with a mild gasoline-like or kerosene-like odor. Liquid at room temperature with low viscosity. Water Reactivity: Insoluble in water; floats on water surface. No significant reaction with water. Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid. PPE: Level B minimum for spill response; SCBA and chemical-protective clothing for fire situations or confined spaces Isolation: ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m downwind; if tank/rail car involved in fire, isolate 800m in all directions — Key Hazards — • FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air. • Vapors are heavier than air and may travel to ignition sources and flash back. • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid breathing vapors, dust, mist, smoke or fumes and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/n-decane-un-2247 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2247 n-Decane Cls3 ERG128 | ERG 128: Initial isolation 50m in all directions; for large spills isolate 150m | allfirefighter.com/hazmat/un/n-decane-un-2247SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/n-decane-un-2247

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2247

UN 2247 is n-Decane, a hazardous material assigned to ERG Guide 128.

Yes. It is a flammable liquid and vapors may form explosive mixtures with air.

ERG Guide 128 applies to UN 2247 for initial isolation, protective actions and first response guidance.

FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection, flame-resistant protection as appropriate and PPE selected from SDS.

Heavy flammable vapors can travel through drains or sewers and ignite remotely, causing flashback or vapor explosion.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.