☣️ UN 2293 • CLASS 3

UN 2293 — 4-Methoxy-4-methylpentan-2- one

Placard: Flammable. ERG Guide 128. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 2293 Quick Details

UN 2293
Product name: 4-Methoxy-4-methylpentan-2- one
DOT Class: 3
Placard type: Flammable
ERG Guide: 128 (check current ERG)
Initial isolation: ERG 128: isolate spill area 50m all directions; for large spills isolate 150m and evacuate downwind 300m initially

Common Hazards of UN 2293

  • HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
  • Vapors may form explosive mixtures with air.
  • Vapors may travel to source of ignition and flash back.
  • Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
  • Vapor explosion hazard indoors, outdoors or in sewers.
  • Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
  • Runoff to sewer may create fire or explosion hazard.
  • Containers may explode when heated.

Chemical Identity & Physical Properties

Also known asMethoxymethylpentanoneMMP4-Methoxy-4-methyl-2-pentanoneMethyl isobutyl methoxy ketone
CAS Number107-70-0
AppearanceColorless liquid with a mild, pleasant odor. Readily evaporates at room temperature.
Flash Point29°C (84°F)
Boiling Point160°C (320°F)
Vapor Density5.0 (heavier than air)
Water ReactivityNo significant reaction with water; slightly soluble
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2293

Extinguishing Media

AFFF foam, alcohol-resistant foam, CO2, dry chemical

PPE Requirements

⚠️ Level B minimum; full protective clothing; SCBA required in confined spaces or heavy vapor areas

Isolation & Evacuation

ERG 128: isolate spill area 50m all directions; for large spills isolate 150m and evacuate downwind 300m initially
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 128).

First Actions for a UN 2293 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
  • Consider initial downwind evacuation for at least 300 meters (1000 feet).
Advertisement

📋 Copy & Share Field Card

UN 2293 — 4-Methoxy-4-methylpentan-2- one
HAZMAT RADIO NOTE — UN 2293 Product: 4-Methoxy-4-methylpentan-2- one Class 3 / Flammable / ERG 128 PPE: Level B minimum; full protective clothing; SCBA required in confined spaces or heavy vapor areas ISOLATION: ERG 128: isolate spill area 50m all directions; for large spills isolate 150m and evacuate downwind 300m initially ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2293 — 4-Methoxy-4-methylpentan-2- one Class: 3 | Placard: Flammable | ERG Guide: 128 Appearance: Colorless liquid with a mild, pleasant odor. Readily evaporates at room temperature. Water Reactivity: No significant reaction with water; slightly soluble Extinguishing: AFFF foam, alcohol-resistant foam, CO2, dry chemical PPE: Level B minimum; full protective clothing; SCBA required in confined spaces or heavy vapor areas Isolation: ERG 128: isolate spill area 50m all directions; for large spills isolate 150m and evacuate downwind 300m initially — Key Hazards — • HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. • Vapors may form explosive mixtures with air. • Vapors may travel to source of ignition and flash back. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/2293 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN2293 4-Methoxy-4-methylpentan-2- one Cls3 ERG128 | allfirefighter.com/hazmat/un/2293SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2293

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2293

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum; full protective clothing; SCBA required in confined spaces or heavy vapor areas

Water reactivity: No significant reaction with water; slightly soluble. Recommended extinguishing: AFFF foam, alcohol-resistant foam, CO2, dry chemical.

ERG Guide 128 recommendation: ERG 128: isolate spill area 50m all directions; for large spills isolate 150m and evacuate downwind 300m initially

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 128 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.