☣️ UN 2332 • CLASS 3

UN 2332 — Acetaldehyde oxime

Placard: Flammable. ERG Guide 129. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2332 is Acetaldehyde oxime, a flammable liquid assigned to ERG Guide 129. Heavy vapors can travel, collect in low areas and flash back from ignition sources.

Hazard overview: FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Response guidance: For UN 2332, isolate the area, eliminate ignition sources, keep vapors out of drains and use SCBA in vapor or fire conditions. Cool containers from a protected distance and select foam/dry chemical/CO2 based on the SDS.

Firefighter training notes: Training for UN 2332 should emphasize vapor travel, low-area accumulation, sewer flashback, foam selection, ignition control, container cooling and vapor monitoring. Use ERG 129, SDS and local SOP.

Regulatory context: Acetaldehyde oxime is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: Acetaldehyde oxime should be stored in approved flammable-liquid containers with ventilation, bonding/grounding where required, spill containment and separation from heat, ignition sources, oxidizers and incompatible materials.

Advertisement

UN 2332 Quick Details

UN 2332
Product name: Acetaldehyde oxime
DOT Class: 3
Placard type: Flammable
ERG Guide: 129 (check current ERG)
Initial isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, evacuate 800m downwind if fire

Common Hazards of UN 2332

  • FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.
  • Runoff to sewers may create fire or explosion hazards.
  • Containers may rupture or explode when heated.
  • Fire may produce irritating and/or toxic smoke.
  • Specific product exposure hazards should be confirmed from SDS.

Chemical Identity & Physical Properties

Colorless to pale yellow liquid with a characteristic pungent odor. Miscible with water and most organic solvents.

Also known asEthanal oximeAcetoximeAldoximeN-Ethylidenehydroxylamine
CAS Number107-29-9
AppearanceColorless to pale yellow liquid with a characteristic pungent odor. Miscible with water and most organic solvents.
Flash Point39°C (102°F)
Boiling Point115°C (239°F)
Vapor Density2.1 (heavier than air)
Water ReactivitySoluble in water; no violent reaction but may hydrolyze slowly
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2332

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

PPE Requirements

⚠️ Level B minimum; SCBA required in enclosed spaces or fire conditions; chemical-resistant gloves and suit

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Isolation & Evacuation

ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, evacuate 800m downwind if fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 129).

First Actions for a UN 2332 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream; keep responders out of low vapor areas.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, mist or smoke and avoid skin or eye contact.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 129, SDS, shipping papers and air monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2332 — Acetaldehyde oxime
HAZMAT RADIO NOTE — UN 2332 Product: Acetaldehyde oxime Class 3 / Flammable / ERG 129 PPE: Level B minimum; SCBA required in enclosed spaces or fire conditions; chemical-resistant gloves and suit ISOLATION: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, evacuate 800m downwind if fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2332 — Acetaldehyde oxime Class: 3 | Placard: Flammable | ERG Guide: 129 Appearance: Colorless to pale yellow liquid with a characteristic pungent odor. Miscible with water and most organic solvents. Water Reactivity: Soluble in water; no violent reaction but may hydrolyze slowly Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid. PPE: Level B minimum; SCBA required in enclosed spaces or fire conditions; chemical-resistant gloves and suit Isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, evacuate 800m downwind if fire — Key Hazards — • FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air. • Vapors are heavier than air and may travel to ignition sources and flash back. • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream; keep responders out of low vapor areas. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/acetaldehyde-oxime-un-2332 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2332 Acetaldehyde oxime Cls3 ERG129 | allfirefighter.com/hazmat/un/acetaldehyde-oxime-un-2332SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/acetaldehyde-oxime-un-2332

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2332

UN 2332 is Acetaldehyde oxime, assigned to ERG Guide 129.

Yes. Acetaldehyde oxime is a flammable liquid and its vapors may form explosive mixtures with air.

FLAMMABLE liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

Heavy flammable vapors can move through drains or sewers and ignite remotely, causing flashback or vapor explosion.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.