☣️ UN 2343 • CLASS 3
UN 2343 — 2-Bromopentane
Placard: Flammable. ERG Guide 130. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
UN 2343 Quick Details
UN 2343
Product name: 2-Bromopentane
DOT Class: 3
Placard type: Flammable
ERG Guide: 130 (check current ERG)
Initial isolation: ERG 130: Isolate spill 50m all directions; for large spills consider initial evacuation 300m downwind
Common Hazards of UN 2343
- HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
- Vapors may form explosive mixtures with air.
- Vapors may travel to source of ignition and flash back.
- Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
- Vapor explosion hazard indoors, outdoors or in sewers.
- Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
- Runoff to sewer may create fire or explosion hazard.
- Containers may explode when heated.
Chemical Identity & Physical Properties
| Also known as | 2-Bromopentanesec-Amyl bromidePentyl bromide2-Pentyl bromide |
| CAS Number | 107-81-3 |
| Appearance | Colorless to pale yellow liquid with a characteristic hydrocarbon odor. Liquid at room temperature. |
| Flash Point | 32°C (90°F) |
| Boiling Point | 117-118°C (243-244°F) |
| Vapor Density | 5.2 (heavier than air) |
| Water Reactivity | Insoluble in water; no significant reaction with water |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Fireground Response Guidance — UN 2343
Extinguishing Media
Alcohol-resistant foam, dry chemical, CO2
PPE Requirements
⚠️ Level B minimum; SCBA and chemical-resistant clothing required; avoid skin contact
Isolation & Evacuation
ERG 130: Isolate spill 50m all directions; for large spills consider initial evacuation 300m downwind
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 130).
First Actions for a UN 2343 Incident
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
- Consider initial downwind evacuation for at least 300 meters (1000 feet).
Advertisement
📋 Copy & Share Field Card
UN 2343 — 2-BromopentaneHAZMAT RADIO NOTE — UN 2343
Product: 2-Bromopentane
Class 3 / Flammable / ERG 130
PPE: Level B minimum; SCBA and chemical-resistant clothing required; avoid skin contact
ISOLATION: ERG 130: Isolate spill 50m all directions; for large spills consider initial evacuation 300m downwind
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 2343 — 2-Bromopentane
Class: 3 | Placard: Flammable | ERG Guide: 130
Appearance: Colorless to pale yellow liquid with a characteristic hydrocarbon odor. Liquid at room temperature.
Water Reactivity: Insoluble in water; no significant reaction with water
Extinguishing: Alcohol-resistant foam, dry chemical, CO2
PPE: Level B minimum; SCBA and chemical-resistant clothing required; avoid skin contact
Isolation: ERG 130: Isolate spill 50m all directions; for large spills consider initial evacuation 300m downwind
— Key Hazards —
• HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
• Vapors may form explosive mixtures with air.
• Vapors may travel to source of ignition and flash back.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Ventilate closed spaces before entering, but only if properly trained and equipped.
SOURCE: allfirefighter.com/hazmat/un/2343 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN2343 2-Bromopentane Cls3 ERG130 | ERG 130: Isolate spill 50m all directions; for large spills consider initial eva | allfirefighter.com/hazmat/un/2343SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions.
Page: https://allfirefighter.com/hazmat/un/2343
Advertisement
Frequently Asked Questions about UN 2343
HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated.
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level B minimum; SCBA and chemical-resistant clothing required; avoid skin contact
Water reactivity: Insoluble in water; no significant reaction with water. Recommended extinguishing: Alcohol-resistant foam, dry chemical, CO2.
ERG Guide 130 recommendation: ERG 130: Isolate spill 50m all directions; for large spills consider initial evacuation 300m downwind
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 130 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles.
This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.