☣️ UN 2372 • CLASS 3

UN 2372 — 1,2-Di-(dimethylamino) ethane

Placard: Flammable. ERG Guide 129. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2372 is 1,2-Di-(dimethylamino) ethane, a flammable corrosive amine assigned to ERG Guide 129. Vapor flashback, alkaline burns and toxic/corrosive runoff are key concerns.

Hazard overview: FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air. Liquid and vapor can burn eyes, skin and respiratory tissue. Vapors are heavier than air and may travel to ignition sources and flash back.

Response guidance: For UN 2372, isolate the area, eliminate ignition sources and use SCBA. Prevent vapor entry into drains, contain alkaline/toxic runoff and select foam, dry chemical or CO2 based on SDS and ERG 129.

Firefighter training notes: Training for UN 2372 should emphasize amine/nitrile exposure, corrosive or toxic runoff, SCBA use, sewer flashback, decontamination, foam selection and container cooling. Use ERG 129, SDS and local SOP.

Regulatory context: 1,2-Di-(dimethylamino) ethane is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: 1,2-Di-(dimethylamino) ethane should be stored in approved flammable/corrosive-liquid containers with ventilation, secondary containment and separation from heat, ignition sources, acids, oxidizers and incompatible materials.

Advertisement

UN 2372 Quick Details

UN 2372
Product name: 1,2-Di-(dimethylamino) ethane
DOT Class: 3
Placard type: Flammable
ERG Guide: 129 (check current ERG)
Initial isolation: ERG 129: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions

Common Hazards of UN 2372

  • FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air.
  • Liquid and vapor can burn eyes, skin and respiratory tissue.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Mixing with water may generate heat and spread alkaline/corrosive contamination.
  • Runoff to sewers may create fire, explosion and corrosive contamination hazards.
  • Fire may produce nitrogen oxides and irritating/toxic smoke.
  • Containers may rupture or explode when heated.

Chemical Identity & Physical Properties

Colorless to pale yellow liquid with a fishy, ammonia-like odor. Hygroscopic and miscible with water.

Also known asTMEDATetramethylethylenediamineN,N,N',N'-TetramethylethylenediamineTetramethyl-1,2-ethanediamine
CAS Number110-18-9
AppearanceColorless to pale yellow liquid with a fishy, ammonia-like odor. Hygroscopic and miscible with water.
Flash Point-15C (5F)
Boiling Point121C (250F)
Vapor Density4.0 (heavier than air)
Water ReactivityMiscible with water; no violent reaction but releases heat on mixing
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2372

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain alkaline/toxic runoff.

PPE Requirements

⚠️ Level B minimum; SCBA required; chemical-resistant gloves and suit due to corrosive amine properties

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, boots, eye/face protection and protective clothing; avoid skin contact.

Isolation & Evacuation

ERG 129: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 129).

First Actions for a UN 2372 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream; keep responders out of low vapor areas.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, mist or smoke and avoid skin or eye contact.
  • Prevent alkaline, toxic or corrosive runoff from entering drains and waterways.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 129, SDS, shipping papers and air monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2372 — 1,2-Di-(dimethylamino) ethane
HAZMAT RADIO NOTE — UN 2372 Product: 1,2-Di-(dimethylamino) ethane Class 3 / Flammable / ERG 129 PPE: Level B minimum; SCBA required; chemical-resistant gloves and suit due to corrosive amine properties ISOLATION: ERG 129: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2372 — 1,2-Di-(dimethylamino) ethane Class: 3 | Placard: Flammable | ERG Guide: 129 Appearance: Colorless to pale yellow liquid with a fishy, ammonia-like odor. Hygroscopic and miscible with water. Water Reactivity: Miscible with water; no violent reaction but releases heat on mixing Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain alkaline/toxic runoff. PPE: Level B minimum; SCBA required; chemical-resistant gloves and suit due to corrosive amine properties Isolation: ERG 129: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions — Key Hazards — • FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air. • Liquid and vapor can burn eyes, skin and respiratory tissue. • Vapors are heavier than air and may travel to ignition sources and flash back. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream; keep responders out of low vapor areas. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/di-ethane-un-2372 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2372 1,2-Di-(dimethylamino) ethane Cls3 ERG129 | allfirefighter.com/hazmat/un/di-ethane-un-2372SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/di-ethane-un-2372

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2372

UN 2372 is 1,2-Di-(dimethylamino) ethane, assigned to ERG Guide 129.

Yes. 1,2-Di-(dimethylamino) ethane is flammable or combustible and also corrosive; vapors may form explosive mixtures with air.

FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air. Liquid and vapor can burn eyes, skin and respiratory tissue. Vapors are heavier than air and may travel to ignition sources and flash back.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, boots, eye/face protection and protective clothing; avoid skin contact.

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain alkaline/toxic runoff.

Runoff may carry flammable liquid plus alkaline, toxic or corrosive contamination into drains or waterways.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.