☣️ UN 2377 • CLASS 3

UN 2377 — 1,1-Dimethoxyethane

Placard: Flammable. ERG Guide 127. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2377 is 1,1-Dimethoxyethane, a highly flammable ether/acetal liquid assigned to ERG Guide 127. Heavy vapor flashback and storage-history review are important.

Hazard overview: HIGHLY FLAMMABLE ether/acetal liquid; vapors may ignite easily and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in drains, basements and confined areas.

Response guidance: For UN 2377, isolate the area, eliminate ignition sources, keep vapors out of drains and use SCBA in vapor or fire conditions. Cool containers from a protected distance and choose foam, dry chemical or CO2 based on SDS and ERG 127.

Firefighter training notes: Training for UN 2377 should emphasize vapor travel, low-area accumulation, sewer flashback, foam selection, ignition control, container cooling and vapor monitoring. Use ERG 127, SDS and local SOP.

Regulatory context: 1,1-Dimethoxyethane is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: 1,1-Dimethoxyethane should be stored in approved flammable-liquid containers with ventilation and ignition control. Track age, inhibitor or oxidation/peroxide concerns where required by SDS and facility SOP.

Advertisement

UN 2377 Quick Details

UN 2377
Product name: 1,1-Dimethoxyethane
DOT Class: 3
Placard type: Flammable
ERG Guide: 127 (check current ERG)
Initial isolation: ERG 127: Isolate spill area immediate 50m all directions; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation

Common Hazards of UN 2377

  • HIGHLY FLAMMABLE ether/acetal liquid; vapors may ignite easily and form explosive mixtures with air.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Vapor explosion hazard exists in drains, basements and confined areas.
  • Some ether/acetal materials may hydrolyze slowly or form unstable oxidation products; verify SDS and storage history.
  • Runoff to sewers may create fire or explosion hazards.
  • Fire may produce irritating and/or toxic smoke.
  • Containers may rupture or explode when heated.

Chemical Identity & Physical Properties

Colorless liquid with a mild, pleasant, ethereal odor. Less dense than water and volatile at room temperature.

Also known asEthylidene dimethyl etherAcetaldehyde dimethyl acetalDimethyl acetalEthylidene methyl ether
CAS Number534-15-6
AppearanceColorless liquid with a mild, pleasant, ethereal odor. Less dense than water and volatile at room temperature.
Flash Point-21C (-6F)
Boiling Point64C (147F)
Vapor Density3.1 (heavier than air)
Water ReactivityNo significant reaction with water; miscible but does not react violently
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2377

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

PPE Requirements

⚠️ Level B minimum; SCBA required in vapor/fire conditions; chemical-resistant gloves and splash protection

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Isolation & Evacuation

ERG 127: Isolate spill area immediate 50m all directions; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 127).

First Actions for a UN 2377 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream; keep responders out of low vapor areas.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, mist or smoke and avoid skin or eye contact.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 127, SDS, shipping papers and air monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2377 — 1,1-Dimethoxyethane
HAZMAT RADIO NOTE — UN 2377 Product: 1,1-Dimethoxyethane Class 3 / Flammable / ERG 127 PPE: Level B minimum; SCBA required in vapor/fire conditions; chemical-resistant gloves and splash protection ISOLATION: ERG 127: Isolate spill area immediate 50m all directions; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2377 — 1,1-Dimethoxyethane Class: 3 | Placard: Flammable | ERG Guide: 127 Appearance: Colorless liquid with a mild, pleasant, ethereal odor. Less dense than water and volatile at room temperature. Water Reactivity: No significant reaction with water; miscible but does not react violently Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid. PPE: Level B minimum; SCBA required in vapor/fire conditions; chemical-resistant gloves and splash protection Isolation: ERG 127: Isolate spill area immediate 50m all directions; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation — Key Hazards — • HIGHLY FLAMMABLE ether/acetal liquid; vapors may ignite easily and form explosive mixtures with air. • Vapors are heavier than air and may travel to ignition sources and flash back. • Vapor explosion hazard exists in drains, basements and confined areas. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream; keep responders out of low vapor areas. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/dimethoxyethane-un-2377 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2377 1,1-Dimethoxyethane Cls3 ERG127 | allfirefighter.com/hazmat/un/dimethoxyethane-un-2377SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/dimethoxyethane-un-2377

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2377

UN 2377 is 1,1-Dimethoxyethane, assigned to ERG Guide 127.

Yes. 1,1-Dimethoxyethane is a flammable liquid and its vapors may form explosive mixtures with air.

HIGHLY FLAMMABLE ether/acetal liquid; vapors may ignite easily and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in drains, basements and confined areas.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

Heavy flammable vapors can move through drains or sewers and ignite remotely, causing flashback or vapor explosion.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.