☣️ UN 2383 • CLASS 3

UN 2383 — Dipropylamine

Placard: Flammable. ERG Guide 132. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2383 is Dipropylamine, a flammable corrosive amine assigned to ERG Guide 132. Vapor flashback, alkaline burns and contaminated runoff are key concerns.

Hazard overview: FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air. Liquid and vapor can burn eyes, skin and respiratory tissue. Vapors are heavier than air and may travel to ignition sources and flash back.

Response guidance: For UN 2383, isolate the area, eliminate ignition sources and use SCBA. Keep vapors out of drains, prevent toxic/corrosive runoff and select foam, dry chemical or CO2 using SDS and ERG 132.

Firefighter training notes: Training for UN 2383 should emphasize toxic/corrosive exposure, SCBA use, skin-contact prevention, sewer flashback, decontamination, runoff control and foam selection. Use ERG 132, SDS and local SOP.

Regulatory context: Dipropylamine is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: Dipropylamine should be stored in approved flammable/toxic or corrosive-liquid containers with ventilation, secondary containment and separation from heat, ignition sources, oxidizers and incompatible materials.

Advertisement

UN 2383 Quick Details

UN 2383
Product name: Dipropylamine
DOT Class: 3
Placard type: Flammable
ERG Guide: 132 (check current ERG)
Initial isolation: ERG 132: isolate spill 50m all directions; for large spill isolate 150m, evacuate 800m downwind if fire

Common Hazards of UN 2383

  • FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air.
  • Liquid and vapor can burn eyes, skin and respiratory tissue.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Mixing with water may generate heat and spread alkaline/corrosive contamination.
  • Runoff to sewers may create fire, explosion and corrosive contamination hazards.
  • Fire may produce nitrogen oxides and irritating/toxic smoke.
  • Containers may rupture or explode when heated.

Chemical Identity & Physical Properties

Colorless to pale yellow liquid with a strong ammonia-like or fishy odor. Liquid at room temperature.

Also known asN-Propyl-1-propanamineDi-n-propylamineDPA1-Propanamine N-propyl
CAS Number142-84-7
AppearanceColorless to pale yellow liquid with a strong ammonia-like or fishy odor. Liquid at room temperature.
Flash Point-17C (1F)
Boiling Point109-111C (228-232F)
Vapor Density3.5 (heavier than air)
Water ReactivitySoluble in water; no violent reaction but forms alkaline solutions
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2383

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain toxic or corrosive runoff.

PPE Requirements

⚠️ Level B minimum; SCBA required; chemical-resistant gloves and suit due to corrosive properties

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, boots, eye/face protection and protective clothing; avoid skin contact.

Isolation & Evacuation

ERG 132: isolate spill 50m all directions; for large spill isolate 150m, evacuate 800m downwind if fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 132).

First Actions for a UN 2383 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream; keep responders out of low vapor areas.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, mist or smoke and avoid skin or eye contact.
  • Prevent toxic, alkaline or corrosive runoff from entering drains and waterways.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 132, SDS, shipping papers and air monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2383 — Dipropylamine
HAZMAT RADIO NOTE — UN 2383 Product: Dipropylamine Class 3 / Flammable / ERG 132 PPE: Level B minimum; SCBA required; chemical-resistant gloves and suit due to corrosive properties ISOLATION: ERG 132: isolate spill 50m all directions; for large spill isolate 150m, evacuate 800m downwind if fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2383 — Dipropylamine Class: 3 | Placard: Flammable | ERG Guide: 132 Appearance: Colorless to pale yellow liquid with a strong ammonia-like or fishy odor. Liquid at room temperature. Water Reactivity: Soluble in water; no violent reaction but forms alkaline solutions Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain toxic or corrosive runoff. PPE: Level B minimum; SCBA required; chemical-resistant gloves and suit due to corrosive properties Isolation: ERG 132: isolate spill 50m all directions; for large spill isolate 150m, evacuate 800m downwind if fire — Key Hazards — • FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air. • Liquid and vapor can burn eyes, skin and respiratory tissue. • Vapors are heavier than air and may travel to ignition sources and flash back. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream; keep responders out of low vapor areas. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/dipropylamine-un-2383 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2383 Dipropylamine Cls3 ERG132 | allfirefighter.com/hazmat/un/dipropylamine-un-2383SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/dipropylamine-un-2383

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2383

UN 2383 is Dipropylamine, assigned to ERG Guide 132.

Yes. Dipropylamine is flammable or combustible and corrosive; vapors may form explosive mixtures with air.

FLAMMABLE and CORROSIVE amine liquid; vapors may ignite and form explosive mixtures with air. Liquid and vapor can burn eyes, skin and respiratory tissue. Vapors are heavier than air and may travel to ignition sources and flash back.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, boots, eye/face protection and protective clothing; avoid skin contact.

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain toxic or corrosive runoff.

Runoff can carry flammable liquid plus toxic, alkaline or corrosive contamination into drains or waterways.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.