☣️ UN 2391 • CLASS 3

Iodomethylpropanes

Placard: Flammable. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 2391
Class: 3
Placard type: Flammable
ERG: Guide 129 (check current ERG)
Isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, downwind 300m
Chemical & Response Details
AppearanceColorless to pale yellow liquid with a characteristic pungent odor. Denser than water and immiscible with water.
Flash PointApproximately 10-15°C (50-59°F)
Boiling PointApproximately 120-130°C (248-266°F)
Vapor Density6.5-7.0 (heavier than air)
Water ReactivityNo significant reaction with water, but immiscible and denser than water
ExtinguishingAlcohol-resistant foam, CO2, dry chemical, water spray for cooling
PPE⚠️ Level B minimum; SCBA required in confined spaces or high vapor concentrations; chemical-resistant gloves and suit
IsolationERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, downwind 300m
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames.
  • Vapors may form explosive mixtures with air.
  • Vapors may travel to source of ignition and flash back.
  • Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
  • Vapor explosion hazard indoors, outdoors or in sewers.
  • Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
  • Runoff to sewer may create fire or explosion hazard.
  • Containers may explode when heated.
First actions (field-minded)
  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
  • Consider initial downwind evacuation for at least 300 meters (1000 feet).
Advertisement
📋 Copy & Share
UN 2391 — Iodomethylpropanes
HAZMAT RADIO NOTE — UN 2391 Product: Iodomethylpropanes Class 3 / Flammable / ERG 129 PPE: Level B minimum; SCBA required in confined spaces or high vapor concentrations; chemical-resistant gloves and suit ISOLATION: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, downwind 300m ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2391 — Iodomethylpropanes Class: 3 | Placard: Flammable | ERG Guide: 129 Appearance: Colorless to pale yellow liquid with a characteristic pungent odor. Denser than water and immiscible with water. Water Reactivity: No significant reaction with water, but immiscible and denser than water Extinguishing: Alcohol-resistant foam, CO2, dry chemical, water spray for cooling PPE: Level B minimum; SCBA required in confined spaces or high vapor concentrations; chemical-resistant gloves and suit Isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all directions, downwind 300m — Key Hazards — • HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. • Vapors may form explosive mixtures with air. • Vapors may travel to source of ignition and flash back. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/2391 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN2391 Iodomethylpropanes Cls3 ERG129 | ERG 129: Small spill isolate 30m all directions; large spill isolate 150m all di | allfirefighter.com/hazmat/un/2391SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2391
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum; SCBA required in confined spaces or high vapor concentrations; chemical-resistant gloves and suit

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 129 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.