☣️ UN 2405 • CLASS 3

UN 2405 — Isopropyl butyrate

Placard: Flammable. ERG Guide 129. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2405 is Isopropyl butyrate, a flammable ester liquid assigned to ERG Guide 129. Heavy vapors can travel to ignition sources and flash back.

Hazard overview: FLAMMABLE ester liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Response guidance: For UN 2405, isolate the area, eliminate ignition sources, keep vapors out of drains and use SCBA in vapor or fire conditions. Cool containers from a protected distance and choose foam, dry chemical or CO2 using SDS and ERG 129.

Firefighter training notes: Training for UN 2405 should emphasize vapor travel, low-area accumulation, sewer flashback, foam selection, ignition control, container cooling and vapor monitoring. Use ERG 129, SDS and local SOP.

Regulatory context: Isopropyl butyrate is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: Isopropyl butyrate should be stored in approved flammable-liquid containers with ventilation, bonding/grounding where required, spill containment and separation from heat, ignition sources, oxidizers and incompatible materials.

Advertisement

UN 2405 Quick Details

UN 2405
Product name: Isopropyl butyrate
DOT Class: 3
Placard type: Flammable
ERG Guide: 129 (check current ERG)
Initial isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 100m, downwind 300m. Fire: isolate 800m if tank/rail car involved

Common Hazards of UN 2405

  • FLAMMABLE ester liquid; vapors may ignite and form explosive mixtures with air.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.
  • Liquid may float on water or form a separate layer, spreading fire or contamination.
  • Runoff to sewers may create fire or explosion hazards.
  • Fire may produce carbon monoxide and irritating/toxic smoke.
  • Containers may rupture or explode when heated.

Chemical Identity & Physical Properties

Clear colorless liquid with a fruity, pineapple-like odor. Liquid at room temperature.

Also known asIsopropyl butanoate2-Propyl butyrateIsopropyl n-butyrateButyric acid isopropyl ester
CAS Number638-11-9
AppearanceClear colorless liquid with a fruity, pineapple-like odor. Liquid at room temperature.
Flash Point2°C (36°F)
Boiling Point136-137°C (277-279°F)
Vapor Density4.5 (heavier than air)
Water ReactivityNo significant reaction with water; insoluble and floats on water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2405

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain contaminated runoff.

PPE Requirements

⚠️ Level B minimum for spill response; full protective clothing and SCBA required in fire or confined space

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Isolation & Evacuation

ERG 129: Small spill isolate 30m all directions; large spill isolate 100m, downwind 300m. Fire: isolate 800m if tank/rail car involved
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 129).

First Actions for a UN 2405 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream; keep responders out of low vapor areas.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, mist or smoke and avoid skin or eye contact.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 129, SDS, shipping papers and air monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2405 — Isopropyl butyrate
HAZMAT RADIO NOTE — UN 2405 Product: Isopropyl butyrate Class 3 / Flammable / ERG 129 PPE: Level B minimum for spill response; full protective clothing and SCBA required in fire or confined space ISOLATION: ERG 129: Small spill isolate 30m all directions; large spill isolate 100m, downwind 300m. Fire: isolate 800m if tank/rail car involved ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2405 — Isopropyl butyrate Class: 3 | Placard: Flammable | ERG Guide: 129 Appearance: Clear colorless liquid with a fruity, pineapple-like odor. Liquid at room temperature. Water Reactivity: No significant reaction with water; insoluble and floats on water Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain contaminated runoff. PPE: Level B minimum for spill response; full protective clothing and SCBA required in fire or confined space Isolation: ERG 129: Small spill isolate 30m all directions; large spill isolate 100m, downwind 300m. Fire: isolate 800m if tank/rail car involved — Key Hazards — • FLAMMABLE ester liquid; vapors may ignite and form explosive mixtures with air. • Vapors are heavier than air and may travel to ignition sources and flash back. • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream; keep responders out of low vapor areas. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/isopropyl-butyrate-un-2405 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2405 Isopropyl butyrate Cls3 ERG129 | allfirefighter.com/hazmat/un/isopropyl-butyrate-un-2405SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/isopropyl-butyrate-un-2405

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2405

UN 2405 is Isopropyl butyrate, assigned to ERG Guide 129.

Yes. Isopropyl butyrate is flammable and its vapors may form explosive mixtures with air.

FLAMMABLE ester liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position; contain contaminated runoff.

Heavy flammable vapors can move through drains or sewers and ignite remotely, causing flashback or vapor explosion.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.