☣️ UN 2684 • CLASS 3

UN 2684 — 3-Diethylaminopropylamine

Placard: Flammable. ERG Guide 132. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 2684 Quick Details

UN 2684
Product name: 3-Diethylaminopropylamine
DOT Class: 3
Placard type: Flammable
ERG Guide: 132 (check current ERG)
Initial isolation: ERG 132: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions

Common Hazards of UN 2684

  • Flammable/combustible material.
  • May be ignited by heat, sparks or flames.
  • Vapors may form explosive mixtures with air.
  • Vapors may travel to source of ignition and flash back.
  • Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
  • Vapor explosion hazard indoors, outdoors or in sewers.
  • Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
  • Runoff to sewer may create fire or explosion hazard.

Chemical Identity & Physical Properties

Also known as3-(Diethylamino)propylamineN,N-Diethyl-1,3-propanediamineDEAPADiethylaminopropylamine
CAS Number104-78-9
AppearanceColorless to pale yellow liquid with an amine-like, fishy odor. Highly hygroscopic and corrosive.
Flash Point42C (108F)
Boiling Point169C (336F)
Vapor Density4.5 (heavier than air)
Water ReactivitySoluble in water, exothermic reaction generates heat but not violent
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2684

Extinguishing Media

Alcohol-resistant foam, CO2, dry chemical; water spray for cooling only

PPE Requirements

⚠️ Level B minimum; SCBA required; chemical-resistant suit due to corrosive amine properties

Isolation & Evacuation

ERG 132: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 132).

First Actions for a UN 2684 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement

📋 Copy & Share Field Card

UN 2684 — 3-Diethylaminopropylamine
HAZMAT RADIO NOTE — UN 2684 Product: 3-Diethylaminopropylamine Class 3 / Flammable / ERG 132 PPE: Level B minimum; SCBA required; chemical-resistant suit due to corrosive amine properties ISOLATION: ERG 132: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2684 — 3-Diethylaminopropylamine Class: 3 | Placard: Flammable | ERG Guide: 132 Appearance: Colorless to pale yellow liquid with an amine-like, fishy odor. Highly hygroscopic and corrosive. Water Reactivity: Soluble in water, exothermic reaction generates heat but not violent Extinguishing: Alcohol-resistant foam, CO2, dry chemical; water spray for cooling only PPE: Level B minimum; SCBA required; chemical-resistant suit due to corrosive amine properties Isolation: ERG 132: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions — Key Hazards — • Flammable/combustible material. • May be ignited by heat, sparks or flames. • Vapors may form explosive mixtures with air. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/2684 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN2684 3-Diethylaminopropylamine Cls3 ERG132 | allfirefighter.com/hazmat/un/2684SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2684

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2684

Flammable/combustible material. May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum; SCBA required; chemical-resistant suit due to corrosive amine properties

Water reactivity: Soluble in water, exothermic reaction generates heat but not violent. Recommended extinguishing: Alcohol-resistant foam, CO2, dry chemical; water spray for cooling only.

ERG Guide 132 recommendation: ERG 132: isolate spill 50m all directions; if tank/rail car involved in fire, isolate 800m all directions

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 132 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.