☣️ UN 3154 • CLASS 2

UN 3154 — Perfluoro(ethyl vinyl ether)

Placard: Flammable Gas. ERG Guide 115. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 3154 is Perfluoro(ethyl vinyl ether), a flammable liquefied fluorinated vinyl ether gas assigned to ERG Guide 115. Flashback, frostbite and cylinder rupture are key hazards.

Hazard overview: EXTREMELY FLAMMABLE liquefied fluorinated vinyl ether gas; may ignite easily by heat, sparks or flames. Gas can form explosive mixtures with air and flash back from ignition sources. Vapors from liquefied gas are initially heavier than air and may spread along the ground.

Response guidance: For UN 3154, eliminate ignition sources, isolate low areas and cool cylinders from protection. Do not extinguish a leaking gas fire unless flow can be stopped safely.

Firefighter training notes: Training for UN 3154 should emphasize cylinder/package recognition, vapor density, air monitoring, SCBA use, frostbite/toxicity controls, isolation and source-control limits. Use ERG 115, SDS and local SOP.

Regulatory context: Perfluoro(ethyl vinyl ether) is regulated as a hazardous material for transport and emergency response. Storage, reporting, exposure, waste and incident-notification duties depend on quantity, package type, formulation and jurisdiction; verify shipping papers, SDS and authority guidance.

Storage & handling: Perfluoro(ethyl vinyl ether) should be stored in secured, compatible cylinders or sample packages away from heat, physical damage and unauthorized access, with ventilation, segregation and emergency planning based on exact gas identity.

Advertisement

UN 3154 Quick Details

UN 3154
Product name: Perfluoro(ethyl vinyl ether)
DOT Class: 2
Placard type: Flammable Gas
ERG Guide: 115 (check current ERG)
Initial isolation: ERG 115: isolate spill/leak area immediately for 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions

Common Hazards of UN 3154

  • EXTREMELY FLAMMABLE liquefied fluorinated vinyl ether gas; may ignite easily by heat, sparks or flames.
  • Gas can form explosive mixtures with air and flash back from ignition sources.
  • Vapors from liquefied gas are initially heavier than air and may spread along the ground.
  • Liquefied gas contact can cause frostbite or cold burns.
  • Cylinders exposed to fire may vent, rupture or rocket.
  • Fire or hot surfaces may produce hydrogen fluoride, carbonyl fluoride-type gases and other toxic/corrosive fluorinated smoke.
  • Runoff or vapor-control water may be fluoride-contaminated and corrosive.

Chemical Identity & Physical Properties

Colorless gas with a faint, ethereal odor. Liquefied under pressure. Heavier than air.

Also known asPEVEPerfluoroethyl vinyl etherEthene, (1,1,2,2-tetrafluoroethoxy)-1,1,2-trifluoro-Perfluoro(ethoxyethene)
CAS Number10493-43-3
AppearanceColorless gas with a faint, ethereal odor. Liquefied under pressure. Heavier than air.
Flash PointNot applicable (gas)
Boiling PointApproximately 4°C (39°F)
Vapor Density7.2 (heavier than air)
Water ReactivityNo significant reaction with water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 3154

Extinguishing Media

Do not extinguish a leaking gas fire unless flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray only to cool cylinders.

PPE Requirements

⚠️ Level B minimum; SCBA required; insulated gloves for cryogenic liquid contact

Use positive-pressure SCBA for releases, fire or confined spaces. Wear eye/face protection and insulated gloves where liquefied or cryogenic gas contact is possible.

Isolation & Evacuation

ERG 115: isolate spill/leak area immediately for 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 115).

First Actions for a UN 3154 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, gas, dust, mist, smoke or fumes and avoid skin or eye contact.
  • Do not touch damaged containers, cylinders, articles or spilled material without proper training and PPE.
  • Prevent contaminated runoff, debris and decontamination waste from spreading.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 115, SDS, shipping papers, markings and monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 3154 — Perfluoro(ethyl vinyl ether)
HAZMAT RADIO NOTE — UN 3154 Product: Perfluoro(ethyl vinyl ether) Class 2 / Flammable Gas / ERG 115 PPE: Level B minimum; SCBA required; insulated gloves for cryogenic liquid contact ISOLATION: ERG 115: isolate spill/leak area immediately for 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 3154 — Perfluoro(ethyl vinyl ether) Class: 2 | Placard: Flammable Gas | ERG Guide: 115 Appearance: Colorless gas with a faint, ethereal odor. Liquefied under pressure. Heavier than air. Water Reactivity: No significant reaction with water Extinguishing: Do not extinguish a leaking gas fire unless flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray only to cool cylinders. PPE: Level B minimum; SCBA required; insulated gloves for cryogenic liquid contact Isolation: ERG 115: isolate spill/leak area immediately for 100m in all directions; if tank/rail car involved in fire, isolate 800m in all directions — Key Hazards — • EXTREMELY FLAMMABLE liquefied fluorinated vinyl ether gas; may ignite easily by heat, sparks or flames. • Gas can form explosive mixtures with air and flash back from ignition sources. • Vapors from liquefied gas are initially heavier than air and may spread along the ground. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/perfluoro-un-3154 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN3154 Perfluoro(ethyl vinyl ether) Cls2 ERG115 | allfirefighter.com/hazmat/un/perfluoro-un-3154SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/perfluoro-un-3154

Related UN Numbers in Class 2

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 3154

UN 3154 is Perfluoro(ethyl vinyl ether), assigned to ERG Guide 115.

Yes. Perfluoro(ethyl vinyl ether) is flammable or contains flammable gas that may form explosive mixtures with air.

EXTREMELY FLAMMABLE liquefied fluorinated vinyl ether gas; may ignite easily by heat, sparks or flames. Gas can form explosive mixtures with air and flash back from ignition sources. Vapors from liquefied gas are initially heavier than air and may spread along the ground.

Use positive-pressure SCBA for releases, fire or confined spaces. Wear eye/face protection and insulated gloves where liquefied or cryogenic gas contact is possible.

Do not extinguish a leaking gas fire unless flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray only to cool cylinders.

Do not extinguish a leaking gas fire unless flow can be stopped safely; otherwise an explosive cloud may form.

Liquefied gas can cause frostbite or cold burns on skin or eyes.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.