☣️ UN 0058 • CLASS 1

UN 0058 — Charges, shaped, without detonator

Placard: Explosive 1.1D. ERG Guide 112. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 0058 Quick Details

UN 0058
Product name: Charges, shaped, without detonator
DOT Class: 1
Placard type: Explosive 1.1D
ERG Guide: 112 (check current ERG)
Initial isolation: ERG 112: Isolate 800m in all directions. Evacuate 1600m in all directions if fire is present. Mass explosion hazard.

Common Hazards of UN 0058

  • Mass explosion hazard — entire load may detonate simultaneously.
  • Severe blast overpressure and fragmentation.
  • Sensitive to heat, shock, and friction.
  • Secondary fire and debris hazard.

Chemical Identity & Physical Properties

Also known asShaped chargesHollow chargesConical chargesLinear shaped chargesJet-forming charges
AppearanceMetallic or composite device with conical or linear cavity lined with metal (typically copper), packed with high explosive. Solid at room temperature, typically gray or tan in color.
Flash PointNot applicable (explosive solid)
Boiling PointNot applicable (explosive solid)
Vapor DensityNot applicable (solid)
Water ReactivityNo significant reaction with water, but water should not be used on fires involving explosives
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 0058

Extinguishing Media

Do not fight fire; evacuate immediately. If absolutely necessary, use water from distance only.

PPE Requirements

⚠️ Full structural firefighting gear with SCBA; withdraw immediately if fire involves explosives. Minimum safe distance 800m.

Isolation & Evacuation

ERG 112: Isolate 800m in all directions. Evacuate 1600m in all directions if fire is present. Mass explosion hazard.
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 112).

First Actions for a UN 0058 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper.
  • Establish large isolation zone — minimum 500 meters in all directions.
  • Stage upwind, uphill; limit personnel to essential responders only.
  • Request Hazmat + law enforcement + additional resources immediately.
  • Do not fight fire — evacuate and isolate; let burn if no life safety risk.
  • Protect exposures only if safe and directed by command.
  • Consult current ERG Guide 112 and follow SOP/SOG.
Advertisement

📋 Copy & Share Field Card

UN 0058 — Charges, shaped, without detonator
HAZMAT RADIO NOTE — UN 0058 Product: Charges, shaped, without detonator Class 1 / Explosive 1.1D / ERG 112 PPE: Full structural firefighting gear with SCBA; withdraw immediately if fire involves explosives. Minimum safe distance 800m. ISOLATION: ERG 112: Isolate 800m in all directions. Evacuate 1600m in all directions if fire is present. Mass explosion hazard. ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0058 — Charges, shaped, without detonator Class: 1 | Placard: Explosive 1.1D | ERG Guide: 112 Appearance: Metallic or composite device with conical or linear cavity lined with metal (typically copper), packed with high explosive. Solid at room temperature, typically gray or tan in color. Water Reactivity: No significant reaction with water, but water should not be used on fires involving explosives Extinguishing: Do not fight fire; evacuate immediately. If absolutely necessary, use water from distance only. PPE: Full structural firefighting gear with SCBA; withdraw immediately if fire involves explosives. Minimum safe distance 800m. Isolation: ERG 112: Isolate 800m in all directions. Evacuate 1600m in all directions if fire is present. Mass explosion hazard. — Key Hazards — • Mass explosion hazard — entire load may detonate simultaneously. • Severe blast overpressure and fragmentation. • Sensitive to heat, shock, and friction. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. • Establish large isolation zone — minimum 500 meters in all directions. • Stage upwind, uphill; limit personnel to essential responders only. • Request Hazmat + law enforcement + additional resources immediately. SOURCE: allfirefighter.com/hazmat/un/0058 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN0058 Charges, shaped, without detonator Cls1 ERG112 | allfirefighter.com/hazmat/un/0058SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/0058

Related UN Numbers in Class 1

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 0058

Mass explosion hazard — entire load may detonate simultaneously. Severe blast overpressure and fragmentation. Sensitive to heat, shock, and friction. Secondary fire and debris hazard.

CALL 911. Then call emergency response telephone number on shipping paper. Establish large isolation zone — minimum 500 meters in all directions. Stage upwind, uphill; limit personnel to essential responders only.

Full structural firefighting gear with SCBA; withdraw immediately if fire involves explosives. Minimum safe distance 800m.

Water reactivity: No significant reaction with water, but water should not be used on fires involving explosives. Recommended extinguishing: Do not fight fire; evacuate immediately. If absolutely necessary, use water from distance only..

ERG Guide 112 recommendation: ERG 112: Isolate 800m in all directions. Evacuate 1600m in all directions if fire is present. Mass explosion hazard.

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 112 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.