☣️ UN 0267 • CLASS 1

UN 0267 — Detonators, non-electric, for blasting

Placard: Explosive 1.4B. ERG Guide 114. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 0267 Quick Details

UN 0267
Product name: Detonators, non-electric, for blasting
DOT Class: 1
Placard type: Explosive 1.4B
ERG Guide: 114 (check current ERG)
Initial isolation: ERG 114: isolate 100m all directions; if large fire or fire involves explosives, isolate 500m and consider evacuation for 800m

Common Hazards of UN 0267

  • Minor blast or fire hazard — limited effect.
  • Localized burning or deflagration possible.
  • Smoke and heat from burning.
  • Low mass explosion risk under normal conditions.

Chemical Identity & Physical Properties

Also known asNon-electric blasting capsShock tube detonatorsSafety fuse detonatorsPyrotechnic delay detonators
AppearanceSmall cylindrical metal or plastic devices containing primary explosive charges. Typically aluminum or copper shell construction with shock tube or safety fuse attachment points.
Flash PointNot applicable (explosive device)
Boiling PointNot applicable (explosive device)
Vapor DensityNot applicable (solid device)
Water ReactivityNo significant reaction with water, but keep dry to maintain reliability
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 0267

Extinguishing Media

Do not fight fire if fire reaches explosives; flooding amounts of water from distance if feasible

PPE Requirements

⚠️ Level B minimum; structural firefighter protective clothing provides limited protection; evacuate area if fire involves explosives

Isolation & Evacuation

ERG 114: isolate 100m all directions; if large fire or fire involves explosives, isolate 500m and consider evacuation for 800m
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 114).

First Actions for a UN 0267 Incident

  • CALL 911. Notify law enforcement.
  • Isolate area; keep unauthorized personnel away.
  • Stage upwind; eliminate ignition sources.
  • Request Hazmat + law enforcement.
  • Consult current ERG Guide 114 and follow SOP/SOG.
Advertisement

📋 Copy & Share Field Card

UN 0267 — Detonators, non-electric, for blasting
HAZMAT RADIO NOTE — UN 0267 Product: Detonators, non-electric, for blasting Class 1 / Explosive 1.4B / ERG 114 PPE: Level B minimum; structural firefighter protective clothing provides limited protection; evacuate area if fire involves explosives ISOLATION: ERG 114: isolate 100m all directions; if large fire or fire involves explosives, isolate 500m and consider evacuation for 800m ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0267 — Detonators, non-electric, for blasting Class: 1 | Placard: Explosive 1.4B | ERG Guide: 114 Appearance: Small cylindrical metal or plastic devices containing primary explosive charges. Typically aluminum or copper shell construction with shock tube or safety fuse attachment points. Water Reactivity: No significant reaction with water, but keep dry to maintain reliability Extinguishing: Do not fight fire if fire reaches explosives; flooding amounts of water from distance if feasible PPE: Level B minimum; structural firefighter protective clothing provides limited protection; evacuate area if fire involves explosives Isolation: ERG 114: isolate 100m all directions; if large fire or fire involves explosives, isolate 500m and consider evacuation for 800m — Key Hazards — • Minor blast or fire hazard — limited effect. • Localized burning or deflagration possible. • Smoke and heat from burning. — First Actions — • CALL 911. Notify law enforcement. • Isolate area; keep unauthorized personnel away. • Stage upwind; eliminate ignition sources. • Request Hazmat + law enforcement. SOURCE: allfirefighter.com/hazmat/un/0267 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN0267 Detonators, non-electric, for blasting Cls1 ERG114 | allfirefighter.com/hazmat/un/0267SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/0267

Related UN Numbers in Class 1

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 0267

Minor blast or fire hazard — limited effect. Localized burning or deflagration possible. Smoke and heat from burning. Low mass explosion risk under normal conditions.

CALL 911. Notify law enforcement. Isolate area; keep unauthorized personnel away. Stage upwind; eliminate ignition sources.

Level B minimum; structural firefighter protective clothing provides limited protection; evacuate area if fire involves explosives

Water reactivity: No significant reaction with water, but keep dry to maintain reliability. Recommended extinguishing: Do not fight fire if fire reaches explosives; flooding amounts of water from distance if feasible.

ERG Guide 114 recommendation: ERG 114: isolate 100m all directions; if large fire or fire involves explosives, isolate 500m and consider evacuation for 800m

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 114 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.