☣️ UN 2380 • CLASS 3

UN 2380 — Dimethyldiethoxysilane

Placard: Flammable. ERG Guide 127. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2380 is Dimethyldiethoxysilane, a flammable alkoxysilane assigned to ERG Guide 127. It can hydrolyze slowly while vapors create flashback hazards.

Hazard overview: FLAMMABLE alkoxysilane liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Hydrolyzes slowly with water or moisture, producing alcohol and siloxane products.

Response guidance: For UN 2380, isolate the area, eliminate ignition sources, keep vapors out of drains and use SCBA in vapor or fire conditions. Cool containers from a protected distance and choose foam, dry chemical or CO2 using SDS and ERG 127.

Firefighter training notes: Training for UN 2380 should emphasize vapor travel, low-area accumulation, sewer flashback, foam selection, ignition control, container cooling and vapor monitoring. Use ERG 127, SDS and local SOP.

Regulatory context: Dimethyldiethoxysilane is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: Dimethyldiethoxysilane should be stored in approved flammable-liquid containers with ventilation, bonding/grounding where required, spill containment and separation from heat, ignition sources, oxidizers and incompatible materials.

Advertisement

UN 2380 Quick Details

UN 2380
Product name: Dimethyldiethoxysilane
DOT Class: 3
Placard type: Flammable
ERG Guide: 127 (check current ERG)
Initial isolation: ERG 127: Small spill isolate 30m all directions; Large spill isolate 150m all directions, evacuate 800m downwind if tank/rail/tank truck involved in fire

Common Hazards of UN 2380

  • FLAMMABLE alkoxysilane liquid; vapors may ignite and form explosive mixtures with air.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Hydrolyzes slowly with water or moisture, producing alcohol and siloxane products.
  • Vapor explosion hazard exists in drains, basements and confined areas.
  • Runoff to sewers may create fire or explosion hazards.
  • Fire may produce silicon oxides, carbon monoxide and irritating smoke.
  • Containers may rupture or explode when heated.

Chemical Identity & Physical Properties

Colorless liquid with a mild, characteristic odor. Liquid at room temperature with relatively low viscosity.

Also known asDiethoxydimethylsilaneDimethyldiethoxysilaneDMDEOSSilane, diethoxydimethyl-
CAS Number78-62-6
AppearanceColorless liquid with a mild, characteristic odor. Liquid at room temperature with relatively low viscosity.
Flash Point-7°C (19°F)
Boiling Point113-114°C (235-237°F)
Vapor Density4.6 (heavier than air)
Water ReactivityHydrolyzes slowly in water, producing ethanol and siloxanes; not violently reactive
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2380

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

PPE Requirements

⚠️ Level B minimum with SCBA; chemical-resistant gloves and suit; avoid all ignition sources

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Isolation & Evacuation

ERG 127: Small spill isolate 30m all directions; Large spill isolate 150m all directions, evacuate 800m downwind if tank/rail/tank truck involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 127).

First Actions for a UN 2380 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream; keep responders out of low vapor areas.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, mist or smoke and avoid skin or eye contact.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 127, SDS, shipping papers and air monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2380 — Dimethyldiethoxysilane
HAZMAT RADIO NOTE — UN 2380 Product: Dimethyldiethoxysilane Class 3 / Flammable / ERG 127 PPE: Level B minimum with SCBA; chemical-resistant gloves and suit; avoid all ignition sources ISOLATION: ERG 127: Small spill isolate 30m all directions; Large spill isolate 150m all directions, evacuate 800m downwind if tank/rail/tank truck involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2380 — Dimethyldiethoxysilane Class: 3 | Placard: Flammable | ERG Guide: 127 Appearance: Colorless liquid with a mild, characteristic odor. Liquid at room temperature with relatively low viscosity. Water Reactivity: Hydrolyzes slowly in water, producing ethanol and siloxanes; not violently reactive Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid. PPE: Level B minimum with SCBA; chemical-resistant gloves and suit; avoid all ignition sources Isolation: ERG 127: Small spill isolate 30m all directions; Large spill isolate 150m all directions, evacuate 800m downwind if tank/rail/tank truck involved in fire — Key Hazards — • FLAMMABLE alkoxysilane liquid; vapors may ignite and form explosive mixtures with air. • Vapors are heavier than air and may travel to ignition sources and flash back. • Hydrolyzes slowly with water or moisture, producing alcohol and siloxane products. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream; keep responders out of low vapor areas. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/dimethyldiethoxysilane-un-2380 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2380 Dimethyldiethoxysilane Cls3 ERG127 | allfirefighter.com/hazmat/un/dimethyldiethoxysilane-un-2380SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/dimethyldiethoxysilane-un-2380

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2380

UN 2380 is Dimethyldiethoxysilane, assigned to ERG Guide 127.

Yes. Dimethyldiethoxysilane is a flammable liquid and its vapors may form explosive mixtures with air.

FLAMMABLE alkoxysilane liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Hydrolyzes slowly with water or moisture, producing alcohol and siloxane products.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

Heavy flammable vapors can move through drains or sewers and ignite remotely, causing flashback or vapor explosion.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.