UN 3213 Bromates, inorganic, aqueous solution, n.o.s. is an oxidizing material. Response depends on the exact salt, concentration and contaminants present.

Hazard overview: Oxidizers supply oxygen or promote combustion. They can intensify fires, react with fuels or reducing agents, and release irritating decomposition gases when heated.

Response guidance: Isolate the spill, remove combustibles and prevent contamination. Cool exposed containers from a safe distance when compatible, and choose extinguishing media using ERG 140 and product-specific SDS.

Firefighter training notes: Train crews to separate oxidizers from fuels, organics and reducing agents, and to cool exposed containers from a safe distance when compatible.

Regulatory context: Class 5.1 oxidizers must be segregated from combustible materials, organic liquids, reducing agents and incompatible acids as required by shipping papers and local code.

Storage & handling: Store away from combustibles, oils, organic materials, reducing agents and heat. Prevent contamination of containers, residue and spill cleanup tools.

Advertisement

UN 3213 Quick Details

UN 3213
Product name: Bromates, inorganic, aqueous solution, n.o.s.
DOT Class: 5
Placard type: Oxidizer
ERG Guide: 140 (check current ERG)
Initial isolation: ERG 140: isolate spill area 50m in all directions; if tank/railcar involved in fire, isolate 800m in all directions

Common Hazards of UN 3213

  • Oxidizer can intensify fire even though it may not be combustible itself.
  • Heat, contamination or contact with fuels, organics or reducing agents can cause rapid decomposition.
  • Containers may rupture or explode when heated.
  • Spills can make combustible materials easier to ignite.
  • Fire may release irritating, toxic or corrosive decomposition gases.
  • Runoff may remain oxidizing and can contaminate drains or waterways.
  • Exact oxidizer concentration and additives must be verified from SDS and shipping papers.

Chemical Identity & Physical Properties

Clear to slightly colored aqueous solution, odorless or slight chlorine-like odor depending on composition. Liquid at room temperature.

Also known asInorganic bromate solutionsBromate salts in waterAqueous bromateBromic acid salts solution
AppearanceClear to slightly colored aqueous solution, odorless or slight chlorine-like odor depending on composition. Liquid at room temperature.
Flash PointNot applicable (aqueous inorganic solution)
Boiling PointApproximately 100C (212F), similar to water
Vapor DensityNot applicable (aqueous solution)
Water ReactivityAlready in aqueous solution; dilution reduces oxidizing potential but avoid contamination with organics or reducing agents
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 3213

Extinguishing Media

Water spray to cool containers, dry chemical for small fires; avoid organic materials and fuels near oxidizer

PPE Requirements

⚠️ Level B minimum with chemical-resistant suit; SCBA required due to potential decomposition gases and oxidizer hazards

Use SCBA and chemical-resistant clothing for spills, fire or unknown concentration. Keep PPE and tools free of oils, fuels and organic contamination.

Isolation & Evacuation

ERG 140: isolate spill area 50m in all directions; if tank/railcar involved in fire, isolate 800m in all directions
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 140).

First Actions for a UN 3213 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command before close approach.
  • Stay upwind, uphill and upstream; avoid low areas where vapors or gases may collect.
  • Avoid breathing vapors, dust, smoke or decomposition products and avoid skin or eye contact.
  • Do not touch damaged containers or spilled material without appropriate PPE and monitoring.
  • Ventilate confined spaces only if trained, equipped and authorized by incident command.
  • Use ERG, SDS, shipping papers and atmospheric/radiation monitoring for final isolation and control decisions.
Advertisement

📋 Copy & Share Field Card

UN 3213 — Bromates, inorganic, aqueous solution, n
HAZMAT RADIO NOTE — UN 3213 Product: Bromates, inorganic, aqueous solution, n.o.s. Class 5 / Oxidizer / ERG 140 PPE: Level B minimum with chemical-resistant suit; SCBA required due to potential decomposition gases and oxidizer hazards ISOLATION: ERG 140: isolate spill area 50m in all directions; if tank/railcar involved in fire, isolate 800m in all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 3213 — Bromates, inorganic, aqueous solution, n.o.s. Class: 5 | Placard: Oxidizer | ERG Guide: 140 Appearance: Clear to slightly colored aqueous solution, odorless or slight chlorine-like odor depending on composition. Liquid at room temperature. Water Reactivity: Already in aqueous solution; dilution reduces oxidizing potential but avoid contamination with organics or reducing agents Extinguishing: Water spray to cool containers, dry chemical for small fires; avoid organic materials and fuels near oxidizer PPE: Level B minimum with chemical-resistant suit; SCBA required due to potential decomposition gases and oxidizer hazards Isolation: ERG 140: isolate spill area 50m in all directions; if tank/railcar involved in fire, isolate 800m in all directions — Key Hazards — • Oxidizer can intensify fire even though it may not be combustible itself. • Heat, contamination or contact with fuels, organics or reducing agents can cause rapid decomposition. • Containers may rupture or explode when heated. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command before close approach. • Stay upwind, uphill and upstream; avoid low areas where vapors or gases may collect. • Avoid breathing vapors, dust, smoke or decomposition products and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/bromates-inorganic-aqueous-solution-un-3213 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN3213 Bromates, inorganic, aqueous solution, n.o.s. Cls5 ERG140 | allfirefighter.com/hazmat/un/bromates-inorganic-aqueous-solution-un-3213SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/bromates-inorganic-aqueous-solution-un-3213

Related UN Numbers in Class 5

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 3213

UN 3213 is Bromates, inorganic, aqueous solution, n.o.s.. It should be treated according to ERG 140 and the exact shipping papers or SDS.

It is an oxidizer that can intensify fire and react dangerously with fuels, organics or reducing agents.

Heat may increase pressure, worsen decomposition, release toxic or irritating gases, or intensify fire depending on the material.

Use positive-pressure SCBA and chemical-resistant protective clothing suitable for the product. Upgrade protection when the identity, concentration or release size is uncertain.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.