UN 3375 — Ammonium nitrate suspension
Placard: Oxidizer. ERG Guide 140. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
UN 3375 is Ammonium nitrate suspension, assigned to ERG Guide 140. First responders should verify the shipping papers and SDS, isolate the area, and base entry, PPE and control tactics on the product's listed hazards.
Hazard overview: The main hazard is oxidizing behavior: it can accelerate burning, react with combustibles, and produce irritating or toxic gases in fire.
Response guidance: For UN 3375, isolate the spill, remove fuels and organic materials, cool containers from distance, prevent runoff, and use ERG 140 for evacuation decisions.
UN 3375 Quick Details
Common Hazards of UN 3375
- These substances will accelerate burning when involved in a fire.
- Some may decompose explosively when heated or involved in a fire.
- May explode from heat or contamination.
- Some will react explosively with hydrocarbons (fuels).
- May ignite combustibles (wood, paper, oil, clothing, etc.).
- Containers may explode when heated.
- Runoff may create fire or explosion hazard.
- Inhalation, ingestion or contact (skin, eyes) with vapors or substance may cause severe injury, burns or death.
Chemical Identity & Physical Properties
White to pale yellow liquid suspension or slurry with a faint ammonia odor. Viscous liquid at room temperature containing suspended ammonium nitrate particles.
| Also known as | Ammonium nitrate slurryAN suspensionLiquid ammonium nitrate fertilizerAmmonium nitrate emulsion |
| Appearance | White to pale yellow liquid suspension or slurry with a faint ammonia odor. Viscous liquid at room temperature containing suspended ammonium nitrate particles. |
| Flash Point | Not applicable (non-flammable oxidizer) |
| Boiling Point | Decomposes before boiling, approximately 210C (410F) |
| Vapor Density | Not applicable (non-volatile liquid) |
| Water Reactivity | Soluble in water; no violent reaction but dilutes oxidizing properties |
Fireground Response Guidance — UN 3375
Extinguishing Media
PPE Requirements
Level B minimum with SCBA; face shield and chemical-resistant suit; avoid all sources of ignition and contamination.
Isolation & Evacuation
First Actions for a UN 3375 Incident
- CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
- Consider initial downwind evacuation for at least 100 meters (330 feet).
📋 Copy & Share Field Card
UN 3375 — Ammonium nitrate suspensionUse for: Quick radio or face-to-face size-up. Short, structured, field-ready.
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.
Use for: Quick text to command or incoming units. Fits in a single SMS.