☣️ UN 2341 • CLASS 3

UN 2341 — 1-Bromo-3-methylbutane

Placard: Flammable. ERG Guide 130. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2341 is 1-Bromo-3-methylbutane, a flammable halogenated organic liquid assigned to ERG Guide 130. Heavy vapor flashback and toxic halogen fire products are key hazards.

Hazard overview: FLAMMABLE halogenated liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Response guidance: For UN 2341, isolate the area, eliminate ignition sources, keep vapors out of drains and use SCBA in vapor or fire conditions. Cool containers from a protected distance and select foam/dry chemical/CO2 based on the SDS.

Firefighter training notes: Training for UN 2341 should emphasize vapor travel, low-area accumulation, sewer flashback, foam selection, ignition control, container cooling and vapor monitoring. Use ERG 130, SDS and local SOP.

Regulatory context: 1-Bromo-3-methylbutane is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: 1-Bromo-3-methylbutane should be stored in approved flammable-liquid containers with ventilation, bonding/grounding where required, spill containment and separation from heat, ignition sources, oxidizers and incompatible materials.

Advertisement

UN 2341 Quick Details

UN 2341
Product name: 1-Bromo-3-methylbutane
DOT Class: 3
Placard type: Flammable
ERG Guide: 130 (check current ERG)
Initial isolation: ERG 130: Small spill isolate 30m all directions; large spill isolate 150m all directions; evacuate downwind if fire threatens

Common Hazards of UN 2341

  • FLAMMABLE halogenated liquid; vapors may ignite and form explosive mixtures with air.
  • Vapors are heavier than air and may travel to ignition sources and flash back.
  • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.
  • Fire may release hydrogen halides and other irritating or toxic decomposition gases.
  • Liquid contact and vapor exposure may irritate eyes, skin and respiratory tract.
  • Runoff to sewers may create fire, explosion and contamination hazards.
  • Containers may rupture or explode when heated.

Chemical Identity & Physical Properties

Clear to pale yellow liquid with a characteristic organic solvent odor. Denser than water and immiscible with water.

Also known asIsoamyl bromideIsopentyl bromide3-Methylbutyl bromide1-Bromo-3-methyl butane
CAS Number107-82-4
AppearanceClear to pale yellow liquid with a characteristic organic solvent odor. Denser than water and immiscible with water.
Flash Point32°C (90°F)
Boiling Point120°C (248°F)
Vapor Density5.2 (heavier than air)
Water ReactivityNo significant reaction; immiscible with water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2341

Extinguishing Media

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

PPE Requirements

⚠️ Level B minimum for spill response; SCBA and chemical-resistant suit; avoid skin contact and inhalation of vapors

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Isolation & Evacuation

ERG 130: Small spill isolate 30m all directions; large spill isolate 150m all directions; evacuate downwind if fire threatens
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 130).

First Actions for a UN 2341 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream; keep responders out of low vapor areas.
  • Eliminate ignition sources if this can be done safely.
  • Avoid breathing vapor, mist or smoke and avoid skin or eye contact.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 130, SDS, shipping papers and air monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2341 — 1-Bromo-3-methylbutane
HAZMAT RADIO NOTE — UN 2341 Product: 1-Bromo-3-methylbutane Class 3 / Flammable / ERG 130 PPE: Level B minimum for spill response; SCBA and chemical-resistant suit; avoid skin contact and inhalation of vapors ISOLATION: ERG 130: Small spill isolate 30m all directions; large spill isolate 150m all directions; evacuate downwind if fire threatens ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2341 — 1-Bromo-3-methylbutane Class: 3 | Placard: Flammable | ERG Guide: 130 Appearance: Clear to pale yellow liquid with a characteristic organic solvent odor. Denser than water and immiscible with water. Water Reactivity: No significant reaction; immiscible with water Extinguishing: Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid. PPE: Level B minimum for spill response; SCBA and chemical-resistant suit; avoid skin contact and inhalation of vapors Isolation: ERG 130: Small spill isolate 30m all directions; large spill isolate 150m all directions; evacuate downwind if fire threatens — Key Hazards — • FLAMMABLE halogenated liquid; vapors may ignite and form explosive mixtures with air. • Vapors are heavier than air and may travel to ignition sources and flash back. • Vapor explosion hazard exists in low areas, drains, sewers and confined spaces. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream; keep responders out of low vapor areas. • Eliminate ignition sources if this can be done safely. SOURCE: allfirefighter.com/hazmat/un/bromo-3-methylbutane-un-2341 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2341 1-Bromo-3-methylbutane Cls3 ERG130 | allfirefighter.com/hazmat/un/bromo-3-methylbutane-un-2341SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/bromo-3-methylbutane-un-2341

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2341

UN 2341 is 1-Bromo-3-methylbutane, assigned to ERG Guide 130.

Yes. 1-Bromo-3-methylbutane is a flammable liquid and its vapors may form explosive mixtures with air.

FLAMMABLE halogenated liquid; vapors may ignite and form explosive mixtures with air. Vapors are heavier than air and may travel to ignition sources and flash back. Vapor explosion hazard exists in low areas, drains, sewers and confined spaces.

Use positive-pressure SCBA for vapor, fire or confined-space exposure. Wear chemical-resistant gloves, eye/face protection and flame-resistant protection as appropriate.

Use alcohol-resistant foam or AFFF where suitable, dry chemical or CO2. Water spray may cool containers from a protected position, but direct streams may spread burning liquid.

Heavy flammable vapors can move through drains or sewers and ignite remotely, causing flashback or vapor explosion.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.