☣️ UN 1957 • CLASS 2

UN 1957 — Deuterium, compressed

Placard: Flammable Gas. ERG Guide 115. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1957 is Deuterium, compressed, a flammable compressed gas assigned to ERG Guide 115. It behaves similarly to hydrogen-type gases, with easy ignition and explosive vapor-air mixtures.

Hazard overview: UN 1957 presents flammable gas, explosion, cylinder rupture and flashback hazards.

Response guidance: For a UN 1957 incident, verify the product with shipping papers, container markings, SDS and ERG Guide 115. Establish incident command, isolate the area, stay upwind, control ignition or downwind hazards, cool exposed containers from a protected distance when appropriate and base entry decisions on monitoring and local SOP.

Firefighter training notes: Training for UN 1957 should emphasize gas vapor travel, flashback, cylinder cooling, BLEVE/rocket hazards, source isolation, invisible or low-lying vapor behavior and ignition control. Use ERG 115, SDS and local SOP.

Regulatory context: Deuterium, compressed is regulated as a hazardous material for transportation and emergency response purposes. Requirements for storage, workplace exposure, emergency planning, spill reporting and waste handling vary by exact product, concentration, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, container markings and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Deuterium, compressed cylinders or containers should be secured in a cool, ventilated gas storage area away from heat, flames, ignition sources, oxidizers where incompatible and physical damage. Follow SDS and local code for gas detection and emergency shutoff.

Advertisement

UN 1957 Quick Details

UN 1957
Product name: Deuterium, compressed
DOT Class: 2
Placard type: Flammable Gas
ERG Guide: 115 (check current ERG)
Initial isolation: ERG 115: isolate 100m all directions; for large spill consider evacuation 800m downwind

Common Hazards of UN 1957

  • EXTREMELY FLAMMABLE compressed gas; may ignite easily by heat, sparks or flame.
  • Can form explosive mixtures with air.
  • Gas may travel to ignition sources and flash back.
  • Cylinders exposed to fire may vent, rupture or rocket.
  • Contact with rapidly expanding gas may cause cold burns or frostbite.
  • Flame may be difficult to see depending on gas and conditions.
  • Do not extinguish a leaking gas fire unless the gas flow can be stopped safely.

Chemical Identity & Physical Properties

Colorless, odorless gas. Isotope of hydrogen with twice the molecular weight. Stored as a compressed gas in cylinders.

Also known asHeavy hydrogenHydrogen-2D2Dideuterium
CAS Number7782-39-0
AppearanceColorless, odorless gas. Isotope of hydrogen with twice the molecular weight. Stored as a compressed gas in cylinders.
Flash PointNot applicable (gas)
Boiling Point-249.5C (-417F)
Vapor Density0.18 (lighter than air, but heavier than hydrogen)
Water ReactivityNo significant reaction with water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1957

Extinguishing Media

Do not extinguish a leaking gas fire unless the gas flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray from a protected distance to cool containers.

PPE Requirements

⚠️ Level B minimum; SCBA required; fire-resistant clothing for fire exposure; insulated gloves for cryogenic contact

Use positive-pressure SCBA for leak, vapor, fire or confined-space exposure. Wear flame-resistant protection, eye/face protection and insulated gloves where liquefied or cryogenic gas contact is possible.

Isolation & Evacuation

ERG 115: isolate 100m all directions; for large spill consider evacuation 800m downwind
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 115).

First Actions for a UN 1957 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid breathing gas, vapor, smoke or mist and avoid skin or eye contact.
  • Eliminate ignition sources if safe and keep gas or vapor out of drains, sewers, basements and low areas.
  • Do not touch damaged containers or spilled/released material unless properly trained and wearing appropriate protective equipment.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the release area and expand the perimeter for fire involvement, cylinder heating, vapor accumulation, unknown gas identity or downwind exposure.
  • Use ERG Guide 115, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 1957 — Deuterium, compressed
HAZMAT RADIO NOTE — UN 1957 Product: Deuterium, compressed Class 2 / Flammable Gas / ERG 115 PPE: Level B minimum; SCBA required; fire-resistant clothing for fire exposure; insulated gloves for cryogenic contact ISOLATION: ERG 115: isolate 100m all directions; for large spill consider evacuation 800m downwind ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1957 — Deuterium, compressed Class: 2 | Placard: Flammable Gas | ERG Guide: 115 Appearance: Colorless, odorless gas. Isotope of hydrogen with twice the molecular weight. Stored as a compressed gas in cylinders. Water Reactivity: No significant reaction with water Extinguishing: Do not extinguish a leaking gas fire unless the gas flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray from a protected distance to cool containers. PPE: Level B minimum; SCBA required; fire-resistant clothing for fire exposure; insulated gloves for cryogenic contact Isolation: ERG 115: isolate 100m all directions; for large spill consider evacuation 800m downwind — Key Hazards — • EXTREMELY FLAMMABLE compressed gas; may ignite easily by heat, sparks or flame. • Can form explosive mixtures with air. • Gas may travel to ignition sources and flash back. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid breathing gas, vapor, smoke or mist and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/deuterium-compressed-un-1957 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1957 Deuterium, compressed Cls2 ERG115 | allfirefighter.com/hazmat/un/deuterium-compressed-un-1957SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/deuterium-compressed-un-1957

Related UN Numbers in Class 2

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1957

UN 1957 is Deuterium, compressed, a hazardous material assigned to ERG Guide 115.

Yes. It is an extremely flammable compressed gas.

ERG Guide 115 applies to UN 1957 for initial isolation, protective actions and first response guidance.

UN 1957 presents flammable gas, explosion, cylinder rupture and flashback hazards.

Use positive-pressure SCBA for leak, vapor, fire or confined-space exposure. Wear flame-resistant protection, eye/face protection and insulated gloves where liquefied or cryogenic gas contact is possible.

Do not extinguish a leaking gas fire unless the gas flow can be stopped safely. Extinguishing without stopping flow can create an explosive vapor cloud.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.