☣️ UN 1033 • CLASS 2

UN 1033 — Dimethyl ether

Placard: Flammable Gas. ERG Guide 115. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1033 is Dimethyl ether, a Class 2 flammable gas assigned to ERG Guide 115. It can ignite easily, form explosive mixtures with air and create cylinder rupture hazards when heated.

Hazard overview: UN 1033 presents flammable vapor, flashback and pressure-container hazards. Fire or heat can cause cylinders to vent or rupture, while released gas may migrate before ignition.

Response guidance: For a UN 1033 incident, responders should confirm the product using shipping papers, cylinder markings, SDS and ERG Guide 115. Establish incident command, isolate the area, stay upwind, eliminate ignition sources when safe, monitor for flammable gas and cool exposed containers from a protected position.

Firefighter training notes: Training for UN 1033 should emphasize flammable vapor behavior, flashback, low-area migration, cylinder heating and ignition control. Common errors include approaching through vapor, operating damaged valves, standing near relief devices or cylinder ends and underestimating explosion potential in confined spaces. Use ERG 115, gas monitoring and local SOP.

Regulatory context: Dimethyl ether is regulated as a Class 2 hazardous material for transportation and emergency response purposes. Cylinder, workplace exposure, storage, reporting and environmental requirements may vary by product, quantity and jurisdiction. Responders should verify current requirements through shipping papers, SDS, cylinder markings, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Dimethyl ether cylinders should be stored secured, upright where required, well ventilated and away from heat, ignition sources, oxidizers, incompatible gases and physical damage. Storage areas should control leaks, cylinder impact, unauthorized access and accumulation of gas in low or confined spaces.

Advertisement

UN 1033 Quick Details

UN 1033
Product name: Dimethyl ether
DOT Class: 2
Placard type: Flammable Gas
ERG Guide: 115 (check current ERG)
Initial isolation: ERG 115: isolate 100m all directions; evacuate 800m downwind if tank/rail car involved in fire

Common Hazards of UN 1033

  • EXTREMELY FLAMMABLE: will be easily ignited by heat, sparks or flames.
  • Will form explosive mixtures with air.
  • Vapors from liquefied gas may be heavier than air and spread along the ground.
  • Vapors may travel to an ignition source and flash back.
  • Cylinders or pressure containers may vent, rupture or rocket when heated.
  • Liquefied gas contact may cause frostbite or cold burns.
  • Released gas can create a wide flammable atmosphere around damaged cylinders, valves or piping.

Chemical Identity & Physical Properties

Colorless gas with a faint, sweet, ethereal odor. Shipped as a liquefied compressed gas under pressure.

Also known asMethyl etherDMEMethoxymethaneWood etherDimethyl oxide
CAS Number115-10-6
AppearanceColorless gas with a faint, sweet, ethereal odor. Shipped as a liquefied compressed gas under pressure.
Flash Point-41C (-42F)
Boiling Point-24C (-11F)
Vapor Density1.6 (heavier than air)
Water ReactivitySoluble in water; no significant violent reaction with water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1033

Extinguishing Media

Dry chemical or CO2 may be used for small gas fires if the gas supply can be shut off; water spray is mainly for cooling exposed cylinders or tanks from a protected position.

PPE Requirements

⚠️ Level B minimum; SCBA with full protective clothing. Cold exposure protection for liquefied gas contact

Use positive-pressure SCBA for fire, leak, vapor cloud or confined-space operations. Structural firefighting gear may protect against fire conditions, but responders should maintain distance from heated cylinders and follow incident command and local SOP.

Isolation & Evacuation

ERG 115: isolate 100m all directions; evacuate 800m downwind if tank/rail car involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 115).

First Actions for a UN 1033 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Do not touch damaged cylinders, tanks, valves or released material unless properly trained and equipped.
  • Eliminate ignition sources if it is safe to do so.
  • Many vapors from liquefied gas are heavier than air and may collect in low or confined areas.
  • Isolate the spill or leak area for at least 100 meters (330 feet) in all directions.
  • Consider initial evacuation for at least 800 meters (1/2 mile) for a large release, fire or heated container.
  • Use ERG Guide 115, shipping papers, air monitoring and incident command to set protective actions.
Advertisement

📋 Copy & Share Field Card

UN 1033 — Dimethyl ether
HAZMAT RADIO NOTE — UN 1033 Product: Dimethyl ether Class 2 / Flammable Gas / ERG 115 PPE: Level B minimum; SCBA with full protective clothing. Cold exposure protection for liquefied gas contact ISOLATION: ERG 115: isolate 100m all directions; evacuate 800m downwind if tank/rail car involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1033 — Dimethyl ether Class: 2 | Placard: Flammable Gas | ERG Guide: 115 Appearance: Colorless gas with a faint, sweet, ethereal odor. Shipped as a liquefied compressed gas under pressure. Water Reactivity: Soluble in water; no significant violent reaction with water Extinguishing: Dry chemical or CO2 may be used for small gas fires if the gas supply can be shut off; water spray is mainly for cooling exposed cylinders or tanks from a protected position. PPE: Level B minimum; SCBA with full protective clothing. Cold exposure protection for liquefied gas contact Isolation: ERG 115: isolate 100m all directions; evacuate 800m downwind if tank/rail car involved in fire — Key Hazards — • EXTREMELY FLAMMABLE: will be easily ignited by heat, sparks or flames. • Will form explosive mixtures with air. • Vapors from liquefied gas may be heavier than air and spread along the ground. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Do not touch damaged cylinders, tanks, valves or released material unless properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/dimethyl-ether-un-1033 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1033 Dimethyl ether Cls2 ERG115 | allfirefighter.com/hazmat/un/dimethyl-ether-un-1033SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/dimethyl-ether-un-1033

Related UN Numbers in Class 2

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1033

UN 1033 is Dimethyl ether, a Class 2 gas assigned to ERG Guide 115.

Yes, it is a flammable gas that can form explosive mixtures with air.

ERG Guide 115 applies to UN 1033 and should be used for initial isolation, protective actions and first response guidance.

UN 1033 presents flammable vapor, flashback and pressure-container hazards. Fire or heat can cause cylinders to vent or rupture, while released gas may migrate before ignition.

Use positive-pressure SCBA for fire, leak, vapor cloud or confined-space operations. Structural firefighting gear may protect against fire conditions, but responders should maintain distance from heated cylinders and follow incident command and local SOP.

Responders should isolate the area, stay upwind, verify the product with shipping papers and SDS, use ERG Guide 115, monitor the atmosphere when possible and follow incident command and local SOP.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.