☣️ UN 2454 • CLASS 2

UN 2454 — Refrigerant gas R-41

Placard: Flammable Gas. ERG Guide 115. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2454 is Refrigerant gas R-41, a flammable liquefied refrigerant gas assigned to ERG Guide 115. Flashback, frostbite and cylinder rupture are key concerns.

Hazard overview: EXTREMELY FLAMMABLE liquefied compressed refrigerant gas; may ignite easily by heat, sparks or flames. Gas can form explosive mixtures with air and flash back from ignition sources. Liquefied gas can cause frostbite and cold burns.

Response guidance: For UN 2454, isolate the leak, eliminate ignition sources and use SCBA. Stop gas flow only if safe; do not extinguish a leaking gas fire unless flow can be stopped, and cool cylinders from protection using ERG 115.

Firefighter training notes: Training for UN 2454 should emphasize flammable gas behavior, source isolation, no-extinguishment-until-flow-stopped tactics, cylinder cooling, flashback and frostbite. Use ERG 115, SDS and local SOP.

Regulatory context: Refrigerant gas R-41 is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: Refrigerant gas R-41 cylinders should be secured in a cool, ventilated gas-storage area away from heat, physical damage and incompatible materials. Provide leak detection, ventilation and emergency planning according to SDS and local code.

Advertisement

UN 2454 Quick Details

UN 2454
Product name: Refrigerant gas R-41
DOT Class: 2
Placard type: Flammable Gas
ERG Guide: 115 (check current ERG)
Initial isolation: ERG 115: isolate 800m all directions for large spill; evacuate 1600m downwind if tank/rail car involved in fire

Common Hazards of UN 2454

  • EXTREMELY FLAMMABLE liquefied compressed refrigerant gas; may ignite easily by heat, sparks or flames.
  • Gas can form explosive mixtures with air and flash back from ignition sources.
  • Liquefied gas can cause frostbite and cold burns.
  • Gas is heavier than air and may collect in low or confined areas.
  • Cylinders exposed to fire may vent, rupture or rocket.
  • Fire or hot surfaces may decompose refrigerant and produce toxic/corrosive fluoride gases.
  • Do not extinguish a leaking gas fire unless the gas flow can be stopped safely.

Chemical Identity & Physical Properties

Colorless, odorless liquefied compressed gas. Shipped as a liquefied gas under its own vapor pressure.

Also known asFluoromethaneMethyl fluorideR-41Freon 41HFC-41
CAS Number593-53-3
AppearanceColorless, odorless liquefied compressed gas. Shipped as a liquefied gas under its own vapor pressure.
Flash PointNot applicable (gas)
Boiling Point-78C (-108F)
Vapor Density1.2 (heavier than air)
Water ReactivityNo significant reaction with water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2454

Extinguishing Media

Do not extinguish a leaking gas fire unless flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray only to cool exposed cylinders.

PPE Requirements

⚠️ Level B minimum; SCBA required in confined spaces or high concentrations; insulated gloves for cryogenic liquid

Use positive-pressure SCBA for gas, fire or confined-space exposure. Wear flame/chemical protection as appropriate and insulated gloves for liquefied-gas frostbite risk.

Isolation & Evacuation

ERG 115: isolate 800m all directions for large spill; evacuate 1600m downwind if tank/rail car involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 115).

First Actions for a UN 2454 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream.
  • Eliminate ignition sources if safe and do not extinguish a leaking gas fire unless flow can be stopped.
  • Avoid breathing vapor, dust, gas, mist, smoke or fumes and avoid skin or eye contact.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 115, SDS, shipping papers and monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2454 — Refrigerant gas R-41
HAZMAT RADIO NOTE — UN 2454 Product: Refrigerant gas R-41 Class 2 / Flammable Gas / ERG 115 PPE: Level B minimum; SCBA required in confined spaces or high concentrations; insulated gloves for cryogenic liquid ISOLATION: ERG 115: isolate 800m all directions for large spill; evacuate 1600m downwind if tank/rail car involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2454 — Refrigerant gas R-41 Class: 2 | Placard: Flammable Gas | ERG Guide: 115 Appearance: Colorless, odorless liquefied compressed gas. Shipped as a liquefied gas under its own vapor pressure. Water Reactivity: No significant reaction with water Extinguishing: Do not extinguish a leaking gas fire unless flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray only to cool exposed cylinders. PPE: Level B minimum; SCBA required in confined spaces or high concentrations; insulated gloves for cryogenic liquid Isolation: ERG 115: isolate 800m all directions for large spill; evacuate 1600m downwind if tank/rail car involved in fire — Key Hazards — • EXTREMELY FLAMMABLE liquefied compressed refrigerant gas; may ignite easily by heat, sparks or flames. • Gas can form explosive mixtures with air and flash back from ignition sources. • Liquefied gas can cause frostbite and cold burns. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream. • Eliminate ignition sources if safe and do not extinguish a leaking gas fire unless flow can be stopped. SOURCE: allfirefighter.com/hazmat/un/refrigerant-gas-r-41-un-2454 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2454 Refrigerant gas R-41 Cls2 ERG115 | allfirefighter.com/hazmat/un/refrigerant-gas-r-41-un-2454SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/refrigerant-gas-r-41-un-2454

Related UN Numbers in Class 2

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2454

UN 2454 is Refrigerant gas R-41, assigned to ERG Guide 115.

Yes. Refrigerant gas R-41 is an extremely flammable gas and may form explosive mixtures with air.

EXTREMELY FLAMMABLE liquefied compressed refrigerant gas; may ignite easily by heat, sparks or flames. Gas can form explosive mixtures with air and flash back from ignition sources. Liquefied gas can cause frostbite and cold burns.

Use positive-pressure SCBA for gas, fire or confined-space exposure. Wear flame/chemical protection as appropriate and insulated gloves for liquefied-gas frostbite risk.

Do not extinguish a leaking gas fire unless flow can be stopped safely. Use dry chemical or CO2 for small fires and water spray only to cool exposed cylinders.

Do not extinguish a leaking gas fire unless the gas flow can be stopped safely; otherwise an explosive vapor cloud may form.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.