☣️ UN 1308 • CLASS 3

UN 1308 — Zirconium suspended in a liquid (flammable)

Placard: Flammable. ERG Guide 170. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1308 is Zirconium suspended in a liquid (flammable), a Class 4 flammable metal solid assigned to ERG Guide 170. The main concerns are dust ignition, intense metal fire, re-ignition and incompatibility with common extinguishing agents.

Hazard overview: UN 1308 presents flammable metal powder and dust hazards. Fine particles can ignite from friction, heat or sparks, burn intensely and may react dangerously with water or incompatible fire agents, especially if dry or dispersed.

Response guidance: For a UN 1308 incident, responders should confirm the product using shipping papers, container markings, SDS and ERG Guide 170. Establish incident command, isolate the area, stay upwind and uphill, remove ignition sources when safe, keep vapors, dust or runoff out of drains where relevant, and use compatible fire-control agents from a protected position.

Firefighter training notes: Training for UN 1308 should emphasize metal fire behavior, dust cloud prevention, incompatible extinguishing agents, re-ignition, dry-agent application and safe standoff. Common errors include using water or foam on burning metal, disturbing powder and underestimating metal oxide fumes. Use ERG 170, SDS and metal-fire SOP.

Regulatory context: Zirconium suspended in a liquid (flammable) is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by formulation, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Zirconium suspended in a liquid (flammable) should be stored in compatible containers away from heat, ignition sources, oxidizers, moisture where incompatible and physical damage. Prevent dust release, container damage and contact with incompatible extinguishing agents or water-reactive conditions as described in the SDS.

Advertisement

UN 1308 Quick Details

UN 1308
Product name: Zirconium suspended in a liquid (flammable)
DOT Class: 3
Placard type: Flammable
ERG Guide: 170 (check current ERG)
Initial isolation: ERG 170: Initial isolation 100m (330 ft) in all directions; for fire, evacuate 800m (0.5 mile) in all directions; treat as both flammable liquid and reactive metal hazard

Common Hazards of UN 1308

  • FLAMMABLE metal powder or reactive metal solid; may be ignited by heat, sparks, friction or flames.
  • Dusts or fine particles may burn rapidly or form explosive mixtures in air.
  • Metal fires can burn with intense heat and may re-ignite after apparent extinguishment.
  • Water or incompatible agents may react with hot or dry metal powder and generate flammable hydrogen.
  • Metal oxide fumes from fire may be hazardous to breathe.
  • Containers may rupture or explode when heated.
  • Avoid creating dust clouds or spreading powder during response.

Chemical Identity & Physical Properties

Gray to black metallic powder suspended in a flammable organic liquid. The suspension appears as a dark slurry or paste with a metallic odor from the carrier solvent.

Also known asZirconium metal powder suspensionZirconium slurryZirconium powder in flammable liquidPyrophoric zirconium suspension
AppearanceGray to black metallic powder suspended in a flammable organic liquid. The suspension appears as a dark slurry or paste with a metallic odor from the carrier solvent.
Flash PointVaries with carrier liquid, typically -20C to 23C (-4F to 73F) depending on solvent used
Boiling PointDepends on carrier solvent, typically 35C to 150C (95F to 302F); zirconium metal melts at 1855C (3371F)
Vapor DensityGreater than 1 (heavier than air) due to carrier solvent vapors
Water ReactivityReacts violently with water producing hydrogen gas and heat; may ignite spontaneously; DO NOT use water
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1308

Extinguishing Media

Use Class D dry powder, dry sand, dry salt, graphite or other compatible dry agent as directed by incident command. Do not use water, foam, CO2 or halogenated agents on burning reactive metal.

PPE Requirements

⚠️ Level B minimum with SCBA; full face shield and chemical-resistant suit; fire proximity suit for fire situations; avoid all ignition sources

Use positive-pressure SCBA for fire, smoke or dust exposure. Protective clothing, gloves and eye/face protection should follow SDS and metal-fire SOP; PPE does not protect against violent metal fire, dust explosion or container rupture hazards.

Isolation & Evacuation

ERG 170: Initial isolation 100m (330 ft) in all directions; for fire, evacuate 800m (0.5 mile) in all directions; treat as both flammable liquid and reactive metal hazard
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 170).

First Actions for a UN 1308 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Eliminate ignition sources if it is safe to do so.
  • Do not create dust clouds or disturb spilled powder unless properly trained and equipped.
  • Keep water, foam, CO2 and halogenated agents away from burning or reactive metal unless incident command confirms compatibility.
  • Use dry Class D agents, dry sand or other compatible dry media when directed by incident command.
  • Isolate the spill or fire area and expand the perimeter if metal powder is burning, dry or dispersed.
  • Use ERG Guide 170, shipping papers, SDS and hazmat/metal-fire SOP for protective actions and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 1308 — Zirconium suspended in a liquid (flammab
HAZMAT RADIO NOTE — UN 1308 Product: Zirconium suspended in a liquid (flammable) Class 3 / Flammable / ERG 170 PPE: Level B minimum with SCBA; full face shield and chemical-resistant suit; fire proximity suit for fire situations; avoid all ignition sources ISOLATION: ERG 170: Initial isolation 100m (330 ft) in all directions; for fire, evacuate 800m (0.5 mile) in all directions; treat as both flammable liquid and reactive metal hazard ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1308 — Zirconium suspended in a liquid (flammable) Class: 3 | Placard: Flammable | ERG Guide: 170 Appearance: Gray to black metallic powder suspended in a flammable organic liquid. The suspension appears as a dark slurry or paste with a metallic odor from the carrier solvent. Water Reactivity: Reacts violently with water producing hydrogen gas and heat; may ignite spontaneously; DO NOT use water Extinguishing: Use Class D dry powder, dry sand, dry salt, graphite or other compatible dry agent as directed by incident command. Do not use water, foam, CO2 or halogenated agents on burning reactive metal. PPE: Level B minimum with SCBA; full face shield and chemical-resistant suit; fire proximity suit for fire situations; avoid all ignition sources Isolation: ERG 170: Initial isolation 100m (330 ft) in all directions; for fire, evacuate 800m (0.5 mile) in all directions; treat as both flammable liquid and reactive metal hazard — Key Hazards — • FLAMMABLE metal powder or reactive metal solid; may be ignited by heat, sparks, friction or flames. • Dusts or fine particles may burn rapidly or form explosive mixtures in air. • Metal fires can burn with intense heat and may re-ignite after apparent extinguishment. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Eliminate ignition sources if it is safe to do so. SOURCE: allfirefighter.com/hazmat/un/zirconium-suspended-in-a-un-1308 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1308 Zirconium suspended in a liquid (flammable) Cls3 ERG170 | allfirefighter.com/hazmat/un/zirconium-suspended-in-a-un-1308SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/zirconium-suspended-in-a-un-1308

Related UN Numbers in Class 3

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1308

UN 1308 is Zirconium suspended in a liquid (flammable), a hazardous material assigned to ERG Guide 170.

Yes. It is a flammable solid, and fine metal powder can burn intensely or form hazardous dust clouds.

ERG Guide 170 applies to UN 1308 for initial isolation, protective actions and first response guidance.

UN 1308 presents flammable metal powder and dust hazards. Fine particles can ignite from friction, heat or sparks, burn intensely and may react dangerously with water or incompatible fire agents, especially if dry or dispersed.

Use positive-pressure SCBA for fire, smoke or dust exposure. Protective clothing, gloves and eye/face protection should follow SDS and metal-fire SOP; PPE does not protect against violent metal fire, dust explosion or container rupture hazards.

Water, foam, CO2 or halogenated agents may be dangerous for burning reactive metal. Use only compatible dry agents under incident command and SDS guidance.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.