☣️ UN 0103 • CLASS 1

UN 0103 — Fuse, igniter, tubular, metal clad

Placard: Explosive 1.4G. ERG Guide 114. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 0103 is Fuse, igniter, tubular, metal clad, a Class 1.4 explosive article assigned to ERG Guide 114. It presents a limited fire or minor blast hazard, but responders still need isolation, smoke protection and shipment verification.

Hazard overview: UN 0103 generally has effects limited to the package or immediate area, but heat or fire can cause localized deflagration, popping, fragments and irritating smoke. The hazard may increase if other explosives, ammunition or pyrotechnics are nearby.

Response guidance: For a UN 0103 incident, responders should confirm the article using shipping papers, markings and ERG Guide 114. Isolate the area, keep personnel out of smoke, control ignition sources when safe, and expand the perimeter if fire involves larger quantities or adjacent explosives.

Firefighter training notes: Training should emphasize the difference between 1.4 limited-effect explosives and higher-hazard Class 1 materials. Common errors include standing too close to heated packages, dismissing smoke hazards and failing to check for adjacent explosives or ammunition.

Regulatory context: Fuse, igniter, tubular, metal clad is regulated as a Class 1 explosive article for transportation. Storage, quantity limits, fire code controls and reporting requirements may vary by jurisdiction. Responders should verify current requirements through shipping papers, product documents and applicable DOT, ATF, OSHA, NFPA or local authority guidance.

Storage & handling: Fuse, igniter, tubular, metal clad should be stored in compatible packaging away from heat, sparks, open flame, impact and unauthorized access. Keep separated from incompatible explosives, propellants and combustible clutter according to product instructions and local fire code.

Advertisement

UN 0103 Quick Details

UN 0103
Product name: Fuse, igniter, tubular, metal clad
DOT Class: 1
Placard type: Explosive 1.4G
ERG Guide: 114 (check current ERG)
Initial isolation: ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire

Common Hazards of UN 0103

  • Minor explosive and fire hazard with effects usually limited to the package or immediate area.
  • Localized burning, deflagration, popping or small fragments may occur if heated.
  • Smoke and heat from burning articles may irritate the eyes and respiratory tract.
  • Low mass explosion risk under normal transport conditions.
  • Heated packages may fail and scatter small articles or fragments.
  • Nearby explosives, ammunition or pyrotechnics may increase the overall incident hazard.

Chemical Identity & Physical Properties

Metal-encased tubular device containing pyrotechnic composition. Typically cylindrical with metal cladding, designed for controlled ignition timing in ordnance systems.

Also known asTubular metal-clad igniterMetal clad tubular fusePyrotechnic igniter fuseOrdnance fuse assembly
AppearanceMetal-encased tubular device containing pyrotechnic composition. Typically cylindrical with metal cladding, designed for controlled ignition timing in ordnance systems.
Flash PointNot applicable (pyrotechnic article)
Boiling PointNot applicable (pyrotechnic article)
Vapor DensityNot applicable (solid article)
Water ReactivityGenerally stable; avoid prolonged water exposure which may degrade pyrotechnic composition
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 0103

Extinguishing Media

Water spray, fog, dry chemical or CO2 may be appropriate for surrounding fires when directed by incident command; avoid close approach to heated articles.

PPE Requirements

⚠️ Structural firefighting gear with SCBA for smoke or fire exposure; maintain distance from heated packages or damaged articles.

Structural firefighting protective clothing with SCBA is appropriate for fire or smoke exposure, with distance maintained from heated packages. Approach and handling should follow incident command and local SOP.

Isolation & Evacuation

ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 114).

First Actions for a UN 0103 Incident

  • CALL 911. Notify law enforcement if ammunition components, explosive articles or ordnance are involved.
  • Keep unauthorized personnel away.
  • Stage upwind and avoid smoke from burning articles.
  • Eliminate ignition sources if it is safe to do so.
  • Isolate the area and expand the perimeter if fire grows or additional explosives are present.
  • Use ERG Guide 114, shipping papers and incident command for isolation and fire response decisions.
Advertisement

📋 Copy & Share Field Card

UN 0103 — Fuse, igniter, tubular, metal clad
HAZMAT RADIO NOTE — UN 0103 Product: Fuse, igniter, tubular, metal clad Class 1 / Explosive 1.4G / ERG 114 PPE: Structural firefighting gear with SCBA for smoke or fire exposure; maintain distance from heated packages or damaged articles. ISOLATION: ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0103 — Fuse, igniter, tubular, metal clad Class: 1 | Placard: Explosive 1.4G | ERG Guide: 114 Appearance: Metal-encased tubular device containing pyrotechnic composition. Typically cylindrical with metal cladding, designed for controlled ignition timing in ordnance systems. Water Reactivity: Generally stable; avoid prolonged water exposure which may degrade pyrotechnic composition Extinguishing: Water spray, fog, dry chemical or CO2 may be appropriate for surrounding fires when directed by incident command; avoid close approach to heated articles. PPE: Structural firefighting gear with SCBA for smoke or fire exposure; maintain distance from heated packages or damaged articles. Isolation: ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire — Key Hazards — • Minor explosive and fire hazard with effects usually limited to the package or immediate area. • Localized burning, deflagration, popping or small fragments may occur if heated. • Smoke and heat from burning articles may irritate the eyes and respiratory tract. — First Actions — • CALL 911. Notify law enforcement if ammunition components, explosive articles or ordnance are involved. • Keep unauthorized personnel away. • Stage upwind and avoid smoke from burning articles. • Eliminate ignition sources if it is safe to do so. SOURCE: allfirefighter.com/hazmat/un/fuse-igniter-tubular-metal-un-0103 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN0103 Fuse, igniter, tubular, metal clad Cls1 ERG114 | allfirefighter.com/hazmat/un/fuse-igniter-tubular-metal-un-0103SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/fuse-igniter-tubular-metal-un-0103

Related UN Numbers in Class 1

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 0103

UN 0103 is Fuse, igniter, tubular, metal clad, a limited-effect Class 1 explosive article assigned to ERG Guide 114.

Not normally when transported as classified, but fire can still cause localized deflagration, fragments and smoke.

ERG Guide 114 applies to UN 0103.

The main hazards are localized fire, popping or deflagration, smoke, heat and small fragments if heated or damaged.

Structural firefighting gear with SCBA is appropriate for smoke or fire exposure, with standoff distance from heated packages.

Isolate the area, keep people away, avoid smoke, control ignition sources when safe and follow ERG 114, shipping papers and incident command.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.