☣️ UN 0103 • CLASS 1

UN 0103 — Fuse, igniter, tubular, metal clad

Placard: Explosive 1.4G. ERG Guide 114. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 0103 identifies a tubular, metal-clad igniter fuse containing pyrotechnic composition, classified as a 1.4G explosive with limited mass explosion risk. This device is designed for controlled ignition timing in ordnance systems and poses a localized deflagration and smoke hazard when involved in fire.

Hazard overview: UN 0103 presents a minor blast and fire hazard with localized burning or deflagration potential rather than a mass explosion risk. Smoke, heat, and possible projectile effects from the metal cladding are the primary concerns when this article is exposed to fire.

Response guidance: Responders should isolate a minimum of 500 meters (1,640 feet) in all directions if a large fire involves UN 0103, and the area should be fully evacuated if articles are directly involved. Water spray may be used for cooling and exposure protection, but large fires involving this material should not be directly fought by emergency personnel.

Advertisement

UN 0103 Quick Details

UN 0103
Product name: Fuse, igniter, tubular, metal clad
DOT Class: 1
Placard type: Explosive 1.4G
ERG Guide: 114 (check current ERG)
Initial isolation: ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire

Common Hazards of UN 0103

  • Minor blast or fire hazard — limited effect.
  • Localized burning or deflagration possible.
  • Smoke and heat from burning.
  • Low mass explosion risk under normal conditions.

Chemical Identity & Physical Properties

UN 0103 is a cylindrical, metal-encased pyrotechnic device with metal cladding engineered to deliver precise ignition timing in ordnance applications.

Also known asTubular metal-clad igniterMetal clad tubular fusePyrotechnic igniter fuseOrdnance fuse assembly
AppearanceMetal-encased tubular device containing pyrotechnic composition. Typically cylindrical with metal cladding, designed for controlled ignition timing in ordnance systems.
Flash PointNot applicable (pyrotechnic article)
Boiling PointNot applicable (pyrotechnic article)
Vapor DensityNot applicable (solid article)
Water ReactivityGenerally stable; avoid prolonged water exposure which may degrade pyrotechnic composition
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 0103

Extinguishing Media

Water spray for cooling, dry chemical, CO2 for small fires; do not fight large fires

PPE Requirements

⚠️ Structural firefighters' protective clothing provides limited protection; minimum Level D for inspection; distance recommended for fire involvement

Structural firefighters' protective clothing provides only limited protection against UN 0103 hazards; a minimum of Level D is required for inspection, but responders should maintain distance whenever fire involvement is possible.

Isolation & Evacuation

ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 114).

First Actions for a UN 0103 Incident

  • CALL 911. Notify law enforcement.
  • Isolate area; keep unauthorized personnel away.
  • Stage upwind; eliminate ignition sources.
  • Request Hazmat + law enforcement.
  • Consult current ERG Guide 114 and follow SOP/SOG.
Advertisement

📋 Copy & Share Field Card

UN 0103 — Fuse, igniter, tubular, metal clad
HAZMAT RADIO NOTE — UN 0103 Product: Fuse, igniter, tubular, metal clad Class 1 / Explosive 1.4G / ERG 114 PPE: Structural firefighters' protective clothing provides limited protection; minimum Level D for inspection; distance recommended for fire involvement ISOLATION: ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0103 — Fuse, igniter, tubular, metal clad Class: 1 | Placard: Explosive 1.4G | ERG Guide: 114 Appearance: Metal-encased tubular device containing pyrotechnic composition. Typically cylindrical with metal cladding, designed for controlled ignition timing in ordnance systems. Water Reactivity: Generally stable; avoid prolonged water exposure which may degrade pyrotechnic composition Extinguishing: Water spray for cooling, dry chemical, CO2 for small fires; do not fight large fires PPE: Structural firefighters' protective clothing provides limited protection; minimum Level D for inspection; distance recommended for fire involvement Isolation: ERG 114: Isolate 500m (1640 ft) in all directions if large fire; evacuate area if article is involved in fire — Key Hazards — • Minor blast or fire hazard — limited effect. • Localized burning or deflagration possible. • Smoke and heat from burning. — First Actions — • CALL 911. Notify law enforcement. • Isolate area; keep unauthorized personnel away. • Stage upwind; eliminate ignition sources. • Request Hazmat + law enforcement. SOURCE: allfirefighter.com/hazmat/un/fuse-igniter-tubular-metal-un-0103 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN0103 Fuse, igniter, tubular, metal clad Cls1 ERG114 | allfirefighter.com/hazmat/un/fuse-igniter-tubular-metal-un-0103SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/fuse-igniter-tubular-metal-un-0103

Related UN Numbers in Class 1

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 0103

UN 0103 is classified as a 1.4G explosive, meaning it can deflagrate and produce fire, smoke, and heat, but it does not pose a mass explosion hazard under normal conditions.

A minimum of Level D personal protective equipment is required for inspection of UN 0103, but structural firefighting gear provides only limited protection and standoff distance is strongly recommended during any fire involvement.

Per ERG Guide 114, responders should isolate at least 500 meters (1,640 feet) in all directions and evacuate the surrounding area if UN 0103 articles are directly involved in fire.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.