☣️ UN 0289 • CLASS 1

Cord, detonating, metal clad

Placard: Explosive 1.4D. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 0289
Class: 1
Placard type: Explosive 1.4D
ERG: Guide 114 (check current ERG)
Isolation: ERG 114: Isolate 100m in all directions; if fire or explosion suspected, evacuate 800m radius; treat as mass explosion hazard if large quantities involved
Chemical & Response Details
Also known asDetonating cordDet cordPrimacordMetal-clad detonating fuseBlasting cord
AppearanceFlexible cord containing a high explosive core (typically PETN) encased in metal sheathing, usually copper or aluminum. Appears as a thin, flexible cable, typically tan or metallic in color.
Flash PointNot applicable (explosive material)
Boiling PointNot applicable (explosive material)
Vapor DensityNot applicable (solid explosive)
Water ReactivityNo significant reaction with water; remains stable when wet
ExtinguishingWater spray acceptable for cooling; avoid direct impact on product; dry chemical, CO2 for small fires
PPE⚠️ Full protective clothing with SCBA required; maintain safe distance from explosive materials; handle only if trained in explosives
IsolationERG 114: Isolate 100m in all directions; if fire or explosion suspected, evacuate 800m radius; treat as mass explosion hazard if large quantities involved
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • Minor blast or fire hazard — limited effect.
  • Localized burning or deflagration possible.
  • Smoke and heat from burning.
  • Low mass explosion risk under normal conditions.
First actions (field-minded)
  • CALL 911. Notify law enforcement.
  • Isolate area; keep unauthorized personnel away.
  • Stage upwind; eliminate ignition sources.
  • Request Hazmat + law enforcement.
  • Consult current ERG Guide 114 and follow SOP/SOG.
Advertisement
📋 Copy & Share
UN 0289 — Cord, detonating, metal clad
HAZMAT RADIO NOTE — UN 0289 Product: Cord, detonating, metal clad Class 1 / Explosive 1.4D / ERG 114 PPE: Full protective clothing with SCBA required; maintain safe distance from explosive materials; handle only if trained in explosives ISOLATION: ERG 114: Isolate 100m in all directions; if fire or explosion suspected, evacuate 800m radius; treat as mass explosion hazard if large quantities involved ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0289 — Cord, detonating, metal clad Class: 1 | Placard: Explosive 1.4D | ERG Guide: 114 Appearance: Flexible cord containing a high explosive core (typically PETN) encased in metal sheathing, usually copper or aluminum. Appears as a thin, flexible cable, typically tan or metallic in color. Water Reactivity: No significant reaction with water; remains stable when wet Extinguishing: Water spray acceptable for cooling; avoid direct impact on product; dry chemical, CO2 for small fires PPE: Full protective clothing with SCBA required; maintain safe distance from explosive materials; handle only if trained in explosives Isolation: ERG 114: Isolate 100m in all directions; if fire or explosion suspected, evacuate 800m radius; treat as mass explosion hazard if large quantities involved — Key Hazards — • Minor blast or fire hazard — limited effect. • Localized burning or deflagration possible. • Smoke and heat from burning. — First Actions — • CALL 911. Notify law enforcement. • Isolate area; keep unauthorized personnel away. • Stage upwind; eliminate ignition sources. • Request Hazmat + law enforcement. SOURCE: allfirefighter.com/hazmat/un/0289 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN0289 Cord, detonating, metal clad Cls1 ERG114 | allfirefighter.com/hazmat/un/0289SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/0289
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

Minor blast or fire hazard — limited effect. Localized burning or deflagration possible. Smoke and heat from burning. Low mass explosion risk under normal conditions.

CALL 911. Notify law enforcement. Isolate area; keep unauthorized personnel away. Stage upwind; eliminate ignition sources.

Full protective clothing with SCBA required; maintain safe distance from explosive materials; handle only if trained in explosives

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 114 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.