☣️ UN 0325 • CLASS 1

UN 0325 — Igniters

Placard: Explosive 1.4G. ERG Guide 114. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 0325 is Igniters, a Class 1.4 explosive article assigned to ERG Guide 114. It presents a limited fire or minor blast hazard, but responders still need isolation, smoke protection and shipment verification.

Hazard overview: UN 0325 presents a localized initiator hazard. Heat, impact, friction, static, electrical energy or mechanical disturbance may cause popping, deflagration or small blast effects, and grouped articles can still injure nearby personnel.

Response guidance: For a UN 0325 incident, responders should confirm the article using shipping papers, markings and ERG Guide 114. Isolate the area, avoid disturbing leads or damaged units, control ignition and static sources when safe, and request explosive specialists if condition or quantity is uncertain.

Firefighter training notes: Training should emphasize the difference between 1.4 limited-effect explosives and higher-hazard Class 1 materials. Common errors include standing too close to heated packages, dismissing smoke hazards and failing to check for adjacent explosives or ammunition.

Regulatory context: Igniters is regulated as a Class 1 explosive article for transportation. Storage, quantity limits, fire code controls and reporting requirements may vary by jurisdiction. Responders should verify current requirements through shipping papers, product documents and applicable DOT, ATF, OSHA, NFPA or local authority guidance.

Storage & handling: Igniters should be stored in compatible packaging away from heat, sparks, open flame, impact and unauthorized access. Keep separated from incompatible explosives, propellants and combustible clutter according to product instructions and local fire code.

Advertisement

UN 0325 Quick Details

UN 0325
Product name: Igniters
DOT Class: 1
Placard type: Explosive 1.4G
ERG Guide: 114 (check current ERG)
Initial isolation: ERG 114: isolate 100m all directions; if fire or cargo involved, isolate 800m all directions and consider evacuation for 800m

Common Hazards of UN 0325

  • Minor explosive hazard with localized blast, popping or fragment effects possible if initiated.
  • Detonators, primers, fuzes or igniters may be sensitive to heat, impact, friction, static or electrical energy depending on design.
  • Smoke and heat from burning articles may irritate the eyes and respiratory tract.
  • Low mass explosion risk under normal transport conditions, but grouped articles can still injure nearby personnel.
  • Heated packages may fail and scatter small articles or fragments.
  • Nearby explosives, ammunition or pyrotechnics may increase the overall incident hazard.

Chemical Identity & Physical Properties

Small devices containing pyrotechnic compositions, typically metal or plastic casings with initiating elements. May contain powder or solid propellant material designed to initiate combustion.

Also known asIgniter assembliesIgnition devicesPyrotechnic ignitersExplosive igniters
AppearanceSmall devices containing pyrotechnic compositions, typically metal or plastic casings with initiating elements. May contain powder or solid propellant material designed to initiate combustion.
Flash PointNot applicable (explosive article)
Boiling PointNot applicable (explosive article)
Vapor DensityNot applicable (solid article)
Water ReactivityMinimal reaction with water; may lose effectiveness if wetted
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 0325

Extinguishing Media

Water spray, fog, dry chemical or CO2 may be appropriate for surrounding fires when directed by incident command; avoid close approach to heated articles.

PPE Requirements

⚠️ Structural firefighting gear with SCBA for smoke or fire exposure; maintain distance from heated packages or damaged articles.

Structural firefighting protective clothing with SCBA is appropriate for fire or smoke exposure, with distance maintained from heated packages. Approach and handling should follow incident command and local SOP.

Isolation & Evacuation

ERG 114: isolate 100m all directions; if fire or cargo involved, isolate 800m all directions and consider evacuation for 800m
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 114).

First Actions for a UN 0325 Incident

  • CALL 911. Notify law enforcement if ammunition components, explosive articles or ordnance are involved.
  • Keep unauthorized personnel away.
  • Stage upwind and avoid smoke from burning articles.
  • Avoid radios, static sources, electrical leads or mechanical disturbance around suspected initiators unless cleared by specialists.
  • Eliminate ignition sources if it is safe to do so.
  • Isolate the area and expand the perimeter if fire grows or additional explosives are present.
  • Use ERG Guide 114, shipping papers and incident command for isolation and fire response decisions.
Advertisement

📋 Copy & Share Field Card

UN 0325 — Igniters
HAZMAT RADIO NOTE — UN 0325 Product: Igniters Class 1 / Explosive 1.4G / ERG 114 PPE: Structural firefighting gear with SCBA for smoke or fire exposure; maintain distance from heated packages or damaged articles. ISOLATION: ERG 114: isolate 100m all directions; if fire or cargo involved, isolate 800m all directions and consider evacuation for 800m ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0325 — Igniters Class: 1 | Placard: Explosive 1.4G | ERG Guide: 114 Appearance: Small devices containing pyrotechnic compositions, typically metal or plastic casings with initiating elements. May contain powder or solid propellant material designed to initiate combustion. Water Reactivity: Minimal reaction with water; may lose effectiveness if wetted Extinguishing: Water spray, fog, dry chemical or CO2 may be appropriate for surrounding fires when directed by incident command; avoid close approach to heated articles. PPE: Structural firefighting gear with SCBA for smoke or fire exposure; maintain distance from heated packages or damaged articles. Isolation: ERG 114: isolate 100m all directions; if fire or cargo involved, isolate 800m all directions and consider evacuation for 800m — Key Hazards — • Minor explosive hazard with localized blast, popping or fragment effects possible if initiated. • Detonators, primers, fuzes or igniters may be sensitive to heat, impact, friction, static or electrical energy depending on design. • Smoke and heat from burning articles may irritate the eyes and respiratory tract. — First Actions — • CALL 911. Notify law enforcement if ammunition components, explosive articles or ordnance are involved. • Keep unauthorized personnel away. • Stage upwind and avoid smoke from burning articles. • Avoid radios, static sources, electrical leads or mechanical disturbance around suspected initiators unless cleared by specialists. SOURCE: allfirefighter.com/hazmat/un/igniters-un-0325 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN0325 Igniters Cls1 ERG114 | ERG 114: isolate 100m all directions; if fire or cargo involved, isolate 800m al | allfirefighter.com/hazmat/un/igniters-un-0325SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/igniters-un-0325

Related UN Numbers in Class 1

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 0325

UN 0325 is Igniters, a limited-effect Class 1 explosive article assigned to ERG Guide 114.

Not normally when transported as classified, but fire can still cause localized deflagration, fragments and smoke.

ERG Guide 114 applies to UN 0325.

The main hazards are localized fire, popping or deflagration, smoke, heat and small fragments if heated or damaged.

Structural firefighting gear with SCBA is appropriate for smoke or fire exposure, with standoff distance from heated packages.

Isolate the area, keep people away, avoid smoke, control ignition sources when safe and follow ERG 114, shipping papers and incident command.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.