☣️ UN 0099 • CLASS 1

UN 0099 — Fracturing devices, explosive, without detonators

Placard: Explosive 1.1D. ERG Guide 112. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 0099 refers to fracturing devices that are explosive but lack detonators, commonly used in oil and gas well perforation and stimulation operations. These solid metallic or composite devices contain high explosives and present a severe mass detonation risk if subjected to heat, shock, or friction.

Hazard overview: UN 0099 presents a mass explosion hazard, meaning the entire load may detonate simultaneously, producing catastrophic blast overpressure and high-velocity fragmentation. These devices are sensitive to heat, shock, and friction, making any incident involving fire or mechanical damage an extreme life-safety emergency.

Response guidance: Emergency responders must isolate a minimum of 500 meters in all directions and evacuate at least 800 meters if fire is involved or a large spill has occurred. No direct approach should be attempted; responders should use dry sand or earth applied from maximum safe distance, and never apply water or foam to burning explosives.

Advertisement

UN 0099 Quick Details

UN 0099
Product name: Fracturing devices, explosive, without detonators
DOT Class: 1
Placard type: Explosive 1.1D
ERG Guide: 112 (check current ERG)
Initial isolation: ERG 112: isolate 500m (1600 ft) all directions; evacuate 800m (0.5 miles) if fire or large spill; mass explosion hazard

Common Hazards of UN 0099

  • Mass explosion hazard — entire load may detonate simultaneously.
  • Severe blast overpressure and fragmentation.
  • Sensitive to heat, shock, and friction.
  • Secondary fire and debris hazard.

Chemical Identity & Physical Properties

UN 0099 fracturing devices are solid metallic or composite cylinders or tubes loaded with high explosives, designed for downhole use in oil and gas well operations.

Also known asExplosive fracturing toolsPerforating guns (explosive)Well fracturing explosivesOil field fracturing charges
AppearanceSolid metallic or composite devices containing high explosives, typically cylindrical or tubular in shape, used in oil and gas well operations.
Flash PointNot applicable (explosive solid)
Boiling PointNot applicable (explosive solid)
Vapor DensityNot applicable (solid)
Water ReactivityNo significant reaction with water, but moisture may affect explosive reliability
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 0099

Extinguishing Media

Do not use water or foam; use dry sand or earth from a distance

PPE Requirements

⚠️ Level A required if fire involves explosives; full bunker gear with SCBA; maintain maximum distance; no direct approach

Responders must wear full bunker gear with SCBA at minimum, and Level A protection is required if fire directly involves the explosive devices; maximum standoff distance must be maintained at all times.

Isolation & Evacuation

ERG 112: isolate 500m (1600 ft) all directions; evacuate 800m (0.5 miles) if fire or large spill; mass explosion hazard
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 112).

First Actions for a UN 0099 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper.
  • Establish large isolation zone — minimum 500 meters in all directions.
  • Stage upwind, uphill; limit personnel to essential responders only.
  • Request Hazmat + law enforcement + additional resources immediately.
  • Do not fight fire — evacuate and isolate; let burn if no life safety risk.
  • Protect exposures only if safe and directed by command.
  • Consult current ERG Guide 112 and follow SOP/SOG.
Advertisement

📋 Copy & Share Field Card

UN 0099 — Fracturing devices, explosive, without d
HAZMAT RADIO NOTE — UN 0099 Product: Fracturing devices, explosive, without detonators Class 1 / Explosive 1.1D / ERG 112 PPE: Level A required if fire involves explosives; full bunker gear with SCBA; maintain maximum distance; no direct approach ISOLATION: ERG 112: isolate 500m (1600 ft) all directions; evacuate 800m (0.5 miles) if fire or large spill; mass explosion hazard ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0099 — Fracturing devices, explosive, without detonators Class: 1 | Placard: Explosive 1.1D | ERG Guide: 112 Appearance: Solid metallic or composite devices containing high explosives, typically cylindrical or tubular in shape, used in oil and gas well operations. Water Reactivity: No significant reaction with water, but moisture may affect explosive reliability Extinguishing: Do not use water or foam; use dry sand or earth from a distance PPE: Level A required if fire involves explosives; full bunker gear with SCBA; maintain maximum distance; no direct approach Isolation: ERG 112: isolate 500m (1600 ft) all directions; evacuate 800m (0.5 miles) if fire or large spill; mass explosion hazard — Key Hazards — • Mass explosion hazard — entire load may detonate simultaneously. • Severe blast overpressure and fragmentation. • Sensitive to heat, shock, and friction. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. • Establish large isolation zone — minimum 500 meters in all directions. • Stage upwind, uphill; limit personnel to essential responders only. • Request Hazmat + law enforcement + additional resources immediately. SOURCE: allfirefighter.com/hazmat/un/fracturing-devices-explosive-without-un-0099 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN0099 Fracturing devices, explosive, without detonators Cls1 ERG112 | allfirefighter.com/hazmat/un/fracturing-devices-explosive-without-un-0099SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/fracturing-devices-explosive-without-un-0099

Related UN Numbers in Class 1

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 0099

Yes, UN 0099 is classified as Explosive 1.1D, meaning the entire shipment can detonate simultaneously, producing a mass explosion with severe blast overpressure and fragmentation.

Full bunker gear with SCBA is the minimum requirement, and Level A chemical protective equipment is required if fire is directly involving the UN 0099 explosive devices.

Per ERG Guide 112, responders should isolate 500 meters (1,600 feet) in all directions and expand evacuation to 800 meters (0.5 miles) if the devices are on fire or a large spill has occurred.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.