☣️ UN 1487 • CLASS 5

UN 1487 — Potassium nitrate and sodium nitrite mixture

Placard: Oxidizer. ERG Guide 140. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1487 is Potassium nitrate and sodium nitrite mixture, a Class 5 nitrate/nitrite oxidizer assigned to ERG Guide 140. It can intensify fire and may decompose when heated or contaminated.

Hazard overview: UN 1487 presents oxidizer, heating and contamination hazards. Keep away from fuels, organics and reducing agents, and control dust or runoff according to SDS and incident command.

Response guidance: For a UN 1487 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 140. Establish incident command, isolate the area, stay upwind, keep fuels and organics away, avoid contaminated absorbents and choose extinguishing or spill-control actions based on ERG, SDS and local SOP.

Firefighter training notes: Training for UN 1487 should emphasize oxidizer fire behavior, separation from fuels and organics, contamination control, dust avoidance, container-heating hazards and correct extinguishing decisions. Common errors include treating oxidizers like ordinary combustibles and using contaminated absorbents. Use ERG 140, SDS and local SOP.

Regulatory context: Potassium nitrate and sodium nitrite mixture is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by formulation, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Potassium nitrate and sodium nitrite mixture should be stored in compatible oxidizer storage away from fuels, organic materials, reducing agents, acids where incompatible, heat, ignition sources and contamination. Keep containers closed, dry, clearly labeled and separated from combustible packaging or spilled residues.

Advertisement

UN 1487 Quick Details

UN 1487
Product name: Potassium nitrate and sodium nitrite mixture
DOT Class: 5
Placard type: Oxidizer
ERG Guide: 140 (check current ERG)
Initial isolation: ERG 140: isolate 25-50m initially; if tank/railcar involved in fire, isolate 800m all directions

Common Hazards of UN 1487

  • OXIDIZER: may intensify fire and accelerate burning of combustible materials.
  • Heating or confinement may cause decomposition and pressure buildup.
  • May ignite combustibles such as wood, paper, oil, clothing, packaging or contaminated absorbents.
  • Nitrates and nitrites may react dangerously with fuels, organic materials, reducing agents or contamination.
  • Containers may rupture or explode when heated.
  • Fire may produce irritating and/or toxic gases.
  • Runoff may spread oxidizing material and create fire, explosion or environmental hazards.
  • Dust, solution or decomposition products may irritate or injure eyes, skin or respiratory tissue.
  • Heating or acid contamination may produce toxic nitrogen oxides.

Chemical Identity & Physical Properties

White to yellowish crystalline solid or granular powder. Odorless. Mixture of two oxidizing salts.

Also known asPotassium nitrate-sodium nitrite mixtureSaltpeter-sodium nitrite blendKNO3-NaNO2 mixture
AppearanceWhite to yellowish crystalline solid or granular powder. Odorless. Mixture of two oxidizing salts.
Flash PointNot applicable (oxidizer solid)
Boiling PointNot applicable (decomposes before boiling)
Vapor DensityNot applicable (solid)
Water ReactivitySoluble in water; no violent reaction but creates oxidizing solution
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1487

Extinguishing Media

Use water spray or flooding water from a protected position when appropriate for oxidizer fires; dry chemical or CO2 may not control fires involving large oxidizer quantities. Keep combustibles and fuels away.

PPE Requirements

⚠️ Level B minimum; SCBA required; avoid contamination with organics or combustibles

Use positive-pressure SCBA for fire, dust, decomposition or confined-space exposure. Chemical-resistant gloves, eye/face protection and protective clothing should be selected from SDS and incident command.

Isolation & Evacuation

ERG 140: isolate 25-50m initially; if tank/railcar involved in fire, isolate 800m all directions
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 140).

First Actions for a UN 1487 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Keep combustibles, fuels, organics, reducing agents and contaminated materials away from the spill.
  • Do not touch or walk through spilled material unless properly trained and wearing appropriate protective equipment.
  • Avoid creating dust clouds and prevent runoff from contacting combustibles, drains or incompatible materials when possible.
  • Ventilate closed spaces before entering, but only if properly trained, equipped and authorized by incident command.
  • Isolate the spill or fire area and expand the perimeter if large quantities, contamination, heating or container involvement are present.
  • Use ERG Guide 140, shipping papers, SDS and local SOP for protective actions and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 1487 — Potassium nitrate and sodium nitrite mix
HAZMAT RADIO NOTE — UN 1487 Product: Potassium nitrate and sodium nitrite mixture Class 5 / Oxidizer / ERG 140 PPE: Level B minimum; SCBA required; avoid contamination with organics or combustibles ISOLATION: ERG 140: isolate 25-50m initially; if tank/railcar involved in fire, isolate 800m all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1487 — Potassium nitrate and sodium nitrite mixture Class: 5 | Placard: Oxidizer | ERG Guide: 140 Appearance: White to yellowish crystalline solid or granular powder. Odorless. Mixture of two oxidizing salts. Water Reactivity: Soluble in water; no violent reaction but creates oxidizing solution Extinguishing: Use water spray or flooding water from a protected position when appropriate for oxidizer fires; dry chemical or CO2 may not control fires involving large oxidizer quantities. Keep combustibles and fuels away. PPE: Level B minimum; SCBA required; avoid contamination with organics or combustibles Isolation: ERG 140: isolate 25-50m initially; if tank/railcar involved in fire, isolate 800m all directions — Key Hazards — • OXIDIZER: may intensify fire and accelerate burning of combustible materials. • Heating or confinement may cause decomposition and pressure buildup. • May ignite combustibles such as wood, paper, oil, clothing, packaging or contaminated absorbents. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Keep combustibles, fuels, organics, reducing agents and contaminated materials away from the spill. SOURCE: allfirefighter.com/hazmat/un/potassium-nitrate-and-sodium-un-1487 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1487 Potassium nitrate and sodium nitrite mixture Cls5 ERG140 | allfirefighter.com/hazmat/un/potassium-nitrate-and-sodium-un-1487SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/potassium-nitrate-and-sodium-un-1487

Related UN Numbers in Class 5

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1487

UN 1487 is Potassium nitrate and sodium nitrite mixture, a Class 5 oxidizer assigned to ERG Guide 140.

No. It is not normally flammable, but it can strongly accelerate burning of other materials.

ERG Guide 140 applies to UN 1487 for initial isolation, protective actions and first response guidance.

UN 1487 presents oxidizer, heating and contamination hazards. Keep away from fuels, organics and reducing agents, and control dust or runoff according to SDS and incident command.

Use positive-pressure SCBA for fire, dust, decomposition or confined-space exposure. Chemical-resistant gloves, eye/face protection and protective clothing should be selected from SDS and incident command.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.