☣️ UN 0107 • CLASS 1

UN 0107 — Fuzes, detonating

Placard: Explosive 1.2B. ERG Guide 112. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 0107 is Fuzes, detonating, a Class 1 explosive assigned to ERG Guide 112. This entry should be treated as a high-consequence explosive hazard where isolation, evacuation and qualified explosive ordnance support are the primary responder priorities.

Hazard overview: UN 0107 presents a severe projection and fragmentation hazard rather than a simple fire problem. Initiation may produce blast overpressure near the source and throw fragments or debris over a wide area. Heat, shock, impact or electrical energy can make the article more dangerous.

Response guidance: For a UN 0107 incident, responders should confirm the material using shipping papers, placards, package markings and ERG Guide 112. Establish incident command, isolate the area, deny entry, request law enforcement and EOD support, and withdraw personnel if fire involves the explosive material or containers.

Firefighter training notes: Training should emphasize recognizing Class 1 explosive placards, establishing command early, using standoff distance, denying entry and requesting bomb squad or EOD support. Common tactical errors include approaching packages for identification, moving damaged items, fighting fire too close and underestimating fragmentation distance. Use ERG 112, shipping papers and local explosive incident SOP.

Regulatory context: Fuzes, detonating is regulated as a Class 1 explosive hazardous material. Transport, storage, reporting and scene-control requirements may involve DOT, ATF, OSHA, military, state or local authorities depending on ownership and quantity. Responders should verify requirements through shipping papers, facility documents, law enforcement and current regulations.

Storage & handling: Fuzes, detonating should be stored only in approved explosive magazines or authorized storage areas, separated from ignition sources, incompatible materials and unauthorized access. Packages should be protected from heat, impact, friction, moisture where relevant and physical damage according to product documentation and applicable explosive storage regulations.

Advertisement

UN 0107 Quick Details

UN 0107
Product name: Fuzes, detonating
DOT Class: 1
Placard type: Explosive 1.2B
ERG Guide: 112 (check current ERG)
Initial isolation: ERG 112: Isolate 500m (1600 ft) all directions; evacuate 1600m (1 mile) all directions if fire or cargo involved in fire

Common Hazards of UN 0107

  • Projection and fragmentation hazard; explosive items may project fragments or debris if initiated.
  • Blast overpressure may be severe in the immediate area.
  • May be sensitive to heat, shock, friction, impact or electrical energy depending on the article.
  • Fire involvement may cause violent rupture, projection or detonation of individual articles.
  • May initiate nearby explosive articles or charges if stored or transported together.
  • Smoke from fire may contain irritating or toxic combustion products.

Chemical Identity & Physical Properties

Metallic or composite assemblies containing explosive charges designed to initiate detonation. Typically cylindrical devices of various sizes, may be brass, aluminum, or plastic construction.

Also known asDetonating fuzesExplosive fuzesBlasting fuzesInitiating fuzesMilitary fuzes
AppearanceMetallic or composite assemblies containing explosive charges designed to initiate detonation. Typically cylindrical devices of various sizes, may be brass, aluminum, or plastic construction.
Flash PointNot applicable (explosive device)
Boiling PointNot applicable (explosive device)
Vapor DensityNot applicable (solid device)
Water ReactivityNo significant reaction with water, but moisture may affect reliability
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 0107

Extinguishing Media

Do not fight fire involving explosives at close range. Use unmanned master streams or remote cooling only if directed by incident command and safe under local SOP.

PPE Requirements

⚠️ No standard PPE protects against blast and fragmentation. Use distance, cover, evacuation, SCBA for smoke exposure and EOD/bomb squad support for any approach.

For UN 0107, distance, cover and evacuation are more important than close-range PPE. Structural firefighting gear and SCBA may be used only for remote exposure protection or support roles; direct approach or handling should be limited to qualified EOD or explosive specialists under incident command.

Isolation & Evacuation

ERG 112: Isolate 500m (1600 ft) all directions; evacuate 1600m (1 mile) all directions if fire or cargo involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 112).

First Actions for a UN 0107 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away and deny entry to the hazard area.
  • Stage responders upwind, uphill and outside the recommended isolation distance.
  • Request law enforcement, bomb squad or EOD, hazmat and additional command resources immediately.
  • Do not handle, move or disturb explosive articles unless directed by qualified explosive ordnance personnel.
  • Do not approach fire-involved articles because projection and fragmentation may occur without warning.
  • Protect exposures only from a safe, remote position if directed by incident command and local SOP.
  • Use ERG Guide 112, shipping papers and incident command to set isolation and evacuation distances.
Advertisement

📋 Copy & Share Field Card

UN 0107 — Fuzes, detonating
HAZMAT RADIO NOTE — UN 0107 Product: Fuzes, detonating Class 1 / Explosive 1.2B / ERG 112 PPE: No standard PPE protects against blast and fragmentation. Use distance, cover, evacuation, SCBA for smoke exposure and EOD/bomb squad support for any approach. ISOLATION: ERG 112: Isolate 500m (1600 ft) all directions; evacuate 1600m (1 mile) all directions if fire or cargo involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 0107 — Fuzes, detonating Class: 1 | Placard: Explosive 1.2B | ERG Guide: 112 Appearance: Metallic or composite assemblies containing explosive charges designed to initiate detonation. Typically cylindrical devices of various sizes, may be brass, aluminum, or plastic construction. Water Reactivity: No significant reaction with water, but moisture may affect reliability Extinguishing: Do not fight fire involving explosives at close range. Use unmanned master streams or remote cooling only if directed by incident command and safe under local SOP. PPE: No standard PPE protects against blast and fragmentation. Use distance, cover, evacuation, SCBA for smoke exposure and EOD/bomb squad support for any approach. Isolation: ERG 112: Isolate 500m (1600 ft) all directions; evacuate 1600m (1 mile) all directions if fire or cargo involved in fire — Key Hazards — • Projection and fragmentation hazard; explosive items may project fragments or debris if initiated. • Blast overpressure may be severe in the immediate area. • May be sensitive to heat, shock, friction, impact or electrical energy depending on the article. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away and deny entry to the hazard area. • Stage responders upwind, uphill and outside the recommended isolation distance. • Request law enforcement, bomb squad or EOD, hazmat and additional command resources immediately. SOURCE: allfirefighter.com/hazmat/un/fuzes-detonating-un-0107 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN0107 Fuzes, detonating Cls1 ERG112 | allfirefighter.com/hazmat/un/fuzes-detonating-un-0107SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/fuzes-detonating-un-0107

Related UN Numbers in Class 1

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 0107

UN 0107 is Fuzes, detonating, a Class 1 explosive assigned to ERG Guide 112.

Yes. UN 0107 should be treated as capable of severe blast and fragmentation; some conditions may allow the entire load to detonate.

ERG Guide 112 applies to UN 0107 and should be used for initial isolation, evacuation and first response decisions.

The main hazards are blast overpressure, fragmentation, fire involvement, shock or heat sensitivity and secondary debris or smoke hazards.

No standard firefighter PPE protects against a close-range detonation. Responders should use distance, cover and evacuation, with EOD or explosive specialists handling any approach.

Keep people away, stage upwind and outside the isolation zone, request law enforcement and EOD support, avoid moving the material and follow ERG 112, shipping papers and incident command.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.