☣️ UN 1755 • CLASS 8

Chromic acid, solution

Placard: Corrosive. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 1755
Class: 8
Placard type: Corrosive
ERG: Guide 154 (check current ERG)
Isolation: ERG 154: isolate spill 25-50m all directions; for large spill consider initial evacuation 100m downwind
Chemical & Response Details
Also known asChromic(VI) acid solutionChromium trioxide solutionChromium(VI) hydroxide solutionChromic anhydride solution
CAS Number7738-94-5
AppearanceDark orange to red liquid with no distinct odor. Highly corrosive aqueous solution of chromium(VI) oxide.
Flash PointNot applicable (aqueous solution, non-flammable)
Boiling PointApproximately 100C (212F), varies with concentration
Vapor DensityNot applicable (aqueous solution)
Water ReactivityAlready in aqueous solution; dilution generates heat but no violent reaction
ExtinguishingWater spray to reduce vapors, soda ash or lime to neutralize; avoid direct water jet on concentrated solution
PPE⚠️ Level B minimum; full face SCBA, chemical-resistant suit, butyl rubber gloves; avoid all skin contact due to severe corrosive and toxic effects
IsolationERG 154: isolate spill 25-50m all directions; for large spill consider initial evacuation 100m downwind
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury
  • Contact with molten substance may cause severe burns to skin and eyes.
  • Avoid any skin contact.
  • Fire may produce irritating, corrosive and/or toxic gases.
  • Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
  • Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
  • Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.).
  • Corrosives in contact with metals may evolve flammable hydrogen gas.
First actions (field-minded)
  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 1755 — Chromic acid, solution
HAZMAT RADIO NOTE — UN 1755 Product: Chromic acid, solution Class 8 / Corrosive / ERG 154 PPE: Level B minimum; full face SCBA, chemical-resistant suit, butyl rubber gloves; avoid all skin contact due to severe corrosive and toxic effects ISOLATION: ERG 154: isolate spill 25-50m all directions; for large spill consider initial evacuation 100m downwind ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1755 — Chromic acid, solution Class: 8 | Placard: Corrosive | ERG Guide: 154 Appearance: Dark orange to red liquid with no distinct odor. Highly corrosive aqueous solution of chromium(VI) oxide. Water Reactivity: Already in aqueous solution; dilution generates heat but no violent reaction Extinguishing: Water spray to reduce vapors, soda ash or lime to neutralize; avoid direct water jet on concentrated solution PPE: Level B minimum; full face SCBA, chemical-resistant suit, butyl rubber gloves; avoid all skin contact due to severe corrosive and toxic effects Isolation: ERG 154: isolate spill 25-50m all directions; for large spill consider initial evacuation 100m downwind — Key Hazards — • TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury • Contact with molten substance may cause severe burns to skin and eyes. • Avoid any skin contact. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/1755 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN1755 Chromic acid, solution Cls8 ERG154 | ERG 154: isolate spill 25-50m all directions; for large spill consider initial e | allfirefighter.com/hazmat/un/1755SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/1755
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.). Corrosives in contact with metals may evolve flammable hydrogen gas.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum; full face SCBA, chemical-resistant suit, butyl rubber gloves; avoid all skin contact due to severe corrosive and toxic effects

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 154 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.