☣️ UN 1792 • CLASS 8
Iodine monochloride, solid
Placard: Corrosive. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 1792
Class: 8
Placard type: Corrosive
ERG: Guide 157 (check current ERG)
Isolation: ERG 157: Initial isolation 60m in all directions; protective action distance 150m downwind for small spill (day), 300m (night); large spill 300m (day), 800m (night)
Chemical & Response Details
| Also known as | Iodine chlorideIodine(I) chlorideWijs' chlorideIClChloroiodine |
| CAS Number | 7790-99-0 |
| Appearance | Red-brown to brownish-black crystalline solid with a pungent, irritating odor. Hygroscopic and fumes in moist air. |
| Flash Point | Not applicable (non-flammable solid) |
| Boiling Point | 97.4C (207.3F) with decomposition |
| Vapor Density | Not applicable (solid, but vapors heavier than air when volatilized) |
| Water Reactivity | Reacts with water to release hydrochloric acid and hypoiodous acid fumes; generates heat and corrosive vapors |
| Extinguishing | Dry chemical, sand, or lime; avoid water-based agents due to reactivity |
| PPE | ⚠️ Level A or B with full-face SCBA required; chemical-resistant suit, gloves, and boots essential due to corrosivity and vapor hazard |
| Isolation | ERG 157: Initial isolation 60m in all directions; protective action distance 150m downwind for small spill (day), 300m (night); large spill 300m (day), 800m (night) |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
- TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance
- Reaction with water or moist air may release toxic, corrosive or flammable gases.
- Reaction with water may generate much heat that will increase the concentration of fumes in the air.
- Fire will produce irritating, corrosive and/or toxic gases.
- Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
- Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
- UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above
- Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).
First actions (field-minded)
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
- For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
- For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 1792 — Iodine monochloride, solid HAZMAT RADIO NOTE — UN 1792
Product: Iodine monochloride, solid
Class 8 / Corrosive / ERG 157
PPE: Level A or B with full-face SCBA required; chemical-resistant suit, gloves, and boots essential due to corrosivity and vapor hazard
ISOLATION: ERG 157: Initial isolation 60m in all directions; protective action distance 150m downwind for small spill (day), 300m (night); large spill 300m (day), 800m (night)
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 1792 — Iodine monochloride, solid
Class: 8 | Placard: Corrosive | ERG Guide: 157
Appearance: Red-brown to brownish-black crystalline solid with a pungent, irritating odor. Hygroscopic and fumes in moist air.
Water Reactivity: Reacts with water to release hydrochloric acid and hypoiodous acid fumes; generates heat and corrosive vapors
Extinguishing: Dry chemical, sand, or lime; avoid water-based agents due to reactivity
PPE: Level A or B with full-face SCBA required; chemical-resistant suit, gloves, and boots essential due to corrosivity and vapor hazard
Isolation: ERG 157: Initial isolation 60m in all directions; protective action distance 150m downwind for small spill (day), 300m (night); large spill 300m (day), 800m (night)
— Key Hazards —
• TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance
• Reaction with water or moist air may release toxic, corrosive or flammable gases.
• Reaction with water may generate much heat that will increase the concentration of fumes in the air.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Ventilate closed spaces before entering, but only if properly trained and equipped.
SOURCE: allfirefighter.com/hazmat/un/1792 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN1792 Iodine monochloride, solid Cls8 ERG157 | allfirefighter.com/hazmat/un/1792SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/1792
Advertisement
FAQ
TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance Reaction with water or moist air may release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level A or B with full-face SCBA required; chemical-resistant suit, gloves, and boots essential due to corrosivity and vapor hazard
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 157 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.