☣️ UN 1802 • CLASS 8

Perchloric acid, with not more than 50% acid

Placard: Corrosive. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 1802
Class: 8
Placard type: Corrosive
ERG: Guide 157 (check current ERG)
Isolation: ERG 157: isolate spill 25-50m; evacuate 300m downwind if large spill; avoid contact with organics
Chemical & Response Details
Also known asPerchloric acid solutionPerchloric acid aqueousHydrogen perchloratePerchloric acid ≤50%
CAS Number7601-90-3
AppearanceColorless to pale yellow aqueous solution with a pungent, irritating odor. Fuming liquid at higher concentrations. Highly corrosive and oxidizing.
Flash PointNot applicable (non-flammable aqueous solution, though oxidizer)
Boiling Point203C (397F) at 72% concentration; lower concentrations boil closer to water
Vapor DensityNot applicable (aqueous solution)
Water ReactivityGenerates heat when diluted; concentrated acid reacts violently with organics and combustibles
ExtinguishingWater spray to dilute, CO2, dry chemical; avoid organics and combustibles near acid
PPE⚠️ Level B minimum; SCBA, full face shield, acid-resistant suit, neoprene/butyl gloves required
IsolationERG 157: isolate spill 25-50m; evacuate 300m downwind if large spill; avoid contact with organics
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance
  • Reaction with water or moist air may release toxic, corrosive or flammable gases.
  • Reaction with water may generate much heat that will increase the concentration of fumes in the air.
  • Fire will produce irritating, corrosive and/or toxic gases.
  • Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
  • Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
  • UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above
  • Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).
First actions (field-minded)
  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 1802 — Perchloric acid, with not more than 50%
HAZMAT RADIO NOTE — UN 1802 Product: Perchloric acid, with not more than 50% acid Class 8 / Corrosive / ERG 157 PPE: Level B minimum; SCBA, full face shield, acid-resistant suit, neoprene/butyl gloves required ISOLATION: ERG 157: isolate spill 25-50m; evacuate 300m downwind if large spill; avoid contact with organics ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1802 — Perchloric acid, with not more than 50% acid Class: 8 | Placard: Corrosive | ERG Guide: 157 Appearance: Colorless to pale yellow aqueous solution with a pungent, irritating odor. Fuming liquid at higher concentrations. Highly corrosive and oxidizing. Water Reactivity: Generates heat when diluted; concentrated acid reacts violently with organics and combustibles Extinguishing: Water spray to dilute, CO2, dry chemical; avoid organics and combustibles near acid PPE: Level B minimum; SCBA, full face shield, acid-resistant suit, neoprene/butyl gloves required Isolation: ERG 157: isolate spill 25-50m; evacuate 300m downwind if large spill; avoid contact with organics — Key Hazards — • TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance • Reaction with water or moist air may release toxic, corrosive or flammable gases. • Reaction with water may generate much heat that will increase the concentration of fumes in the air. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/1802 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN1802 Perchloric acid, with not more than 50% acid Cls8 ERG157 | allfirefighter.com/hazmat/un/1802SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/1802
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance Reaction with water or moist air may release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum; SCBA, full face shield, acid-resistant suit, neoprene/butyl gloves required

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 157 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.