☣️ UN 2817 • CLASS 8

Ammonium hydrogendifluoride, solution

Placard: Corrosive. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 2817
Class: 8
Placard type: Corrosive
ERG: Guide 154 (check current ERG)
Isolation: ERG 154: isolate spill 25-50m all directions; for large spill isolate 100m and evacuate downwind 300m initially
Chemical & Response Details
Also known asAmmonium bifluoride solutionAmmonium hydrogen fluoride solutionAmmonium acid fluoride solutionABF solution
CAS Number1341-49-7
AppearanceClear to slightly colored aqueous solution with a pungent, irritating odor. Highly corrosive liquid at room temperature.
Flash PointNot applicable (aqueous solution)
Boiling PointApproximately 100-120C (212-248F) depending on concentration
Vapor DensityNot applicable (aqueous solution)
Water ReactivityAlready in aqueous solution; dilution with water reduces corrosivity but releases heat
ExtinguishingDry chemical, CO2 for small fires; avoid direct water streams on spills
PPE⚠️ Level B minimum with full face SCBA; acid-resistant suit, gloves, and boots required; avoid all skin contact
IsolationERG 154: isolate spill 25-50m all directions; for large spill isolate 100m and evacuate downwind 300m initially
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury
  • Contact with molten substance may cause severe burns to skin and eyes.
  • Avoid any skin contact.
  • Fire may produce irritating, corrosive and/or toxic gases.
  • Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
  • Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
  • Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.).
  • Corrosives in contact with metals may evolve flammable hydrogen gas.
First actions (field-minded)
  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 2817 — Ammonium hydrogendifluoride, solution
HAZMAT RADIO NOTE — UN 2817 Product: Ammonium hydrogendifluoride, solution Class 8 / Corrosive / ERG 154 PPE: Level B minimum with full face SCBA; acid-resistant suit, gloves, and boots required; avoid all skin contact ISOLATION: ERG 154: isolate spill 25-50m all directions; for large spill isolate 100m and evacuate downwind 300m initially ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2817 — Ammonium hydrogendifluoride, solution Class: 8 | Placard: Corrosive | ERG Guide: 154 Appearance: Clear to slightly colored aqueous solution with a pungent, irritating odor. Highly corrosive liquid at room temperature. Water Reactivity: Already in aqueous solution; dilution with water reduces corrosivity but releases heat Extinguishing: Dry chemical, CO2 for small fires; avoid direct water streams on spills PPE: Level B minimum with full face SCBA; acid-resistant suit, gloves, and boots required; avoid all skin contact Isolation: ERG 154: isolate spill 25-50m all directions; for large spill isolate 100m and evacuate downwind 300m initially — Key Hazards — • TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury • Contact with molten substance may cause severe burns to skin and eyes. • Avoid any skin contact. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/2817 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN2817 Ammonium hydrogendifluoride, solution Cls8 ERG154 | allfirefighter.com/hazmat/un/2817SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2817
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.). Corrosives in contact with metals may evolve flammable hydrogen gas.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum with full face SCBA; acid-resistant suit, gloves, and boots required; avoid all skin contact

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 154 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.