☣️ UN 3301 • CLASS 8

UN 3301 — Corrosive liquid, self-heating, n.o.s.

Placard: Corrosive. ERG Guide 136. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 3301 Quick Details

UN 3301
Product name: Corrosive liquid, self-heating, n.o.s.
DOT Class: 8
Placard type: Corrosive
ERG Guide: 136 (check current ERG)
Initial isolation: ERG 136: isolate spill area at least 25-50m in all directions; if fire or large spill, isolate 800m and evacuate downwind

Common Hazards of UN 3301

  • Extremely flammable; will ignite itself if exposed to air.
  • Burns rapidly, releasing dense, white, irritating fumes.
  • Substance may be transported in a molten form.
  • May re-ignite after fire is extinguished.
  • Corrosives in contact with metals may evolve flammable hydrogen gas.
  • Containers may explode when heated.
  • Fire will produce irritating, corrosive and/or toxic gases.
  • TOXIC and/or CORROSIVE; ingestion of substance or inhalation of decomposition products will cause

Chemical Identity & Physical Properties

Also known asCorrosive liquid, self-heating, not otherwise specifiedSelf-heating corrosive liquidUN3301
AppearanceAppearance varies depending on specific substance; typically a corrosive liquid that may be transported in molten form. Self-heating properties mean it can spontaneously ignite when exposed to air.
Flash PointNot applicable (self-heating material)
Boiling PointVariable depending on specific substance
Vapor DensityVariable depending on specific substance, typically heavier than air
Water ReactivityMay react with water generating heat and corrosive fumes; avoid water contact
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 3301

Extinguishing Media

Dry chemical, CO2, sand; do not use water or foam due to corrosive nature and self-heating properties

PPE Requirements

⚠️ Level A or B with SCBA required; full chemical-resistant suit; avoid all contact due to corrosive and self-heating hazards

Isolation & Evacuation

ERG 136: isolate spill area at least 25-50m in all directions; if fire or large spill, isolate 800m and evacuate downwind
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 136).

First Actions for a UN 3301 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Stay upwind, uphill and/or upstream.
  • Keep unauthorized personnel away.
  • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement

📋 Copy & Share Field Card

UN 3301 — Corrosive liquid, self-heating, n.o.s.
HAZMAT RADIO NOTE — UN 3301 Product: Corrosive liquid, self-heating, n.o.s. Class 8 / Corrosive / ERG 136 PPE: Level A or B with SCBA required; full chemical-resistant suit; avoid all contact due to corrosive and self-heating hazards ISOLATION: ERG 136: isolate spill area at least 25-50m in all directions; if fire or large spill, isolate 800m and evacuate downwind ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 3301 — Corrosive liquid, self-heating, n.o.s. Class: 8 | Placard: Corrosive | ERG Guide: 136 Appearance: Appearance varies depending on specific substance; typically a corrosive liquid that may be transported in molten form. Self-heating properties mean it can spontaneously ignite when exposed to air. Water Reactivity: May react with water generating heat and corrosive fumes; avoid water contact Extinguishing: Dry chemical, CO2, sand; do not use water or foam due to corrosive nature and self-heating properties PPE: Level A or B with SCBA required; full chemical-resistant suit; avoid all contact due to corrosive and self-heating hazards Isolation: ERG 136: isolate spill area at least 25-50m in all directions; if fire or large spill, isolate 800m and evacuate downwind — Key Hazards — • Extremely flammable; will ignite itself if exposed to air. • Burns rapidly, releasing dense, white, irritating fumes. • Substance may be transported in a molten form. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Stay upwind, uphill and/or upstream. • Keep unauthorized personnel away. • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters SOURCE: allfirefighter.com/hazmat/un/3301 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN3301 Corrosive liquid, self-heating, n.o.s. Cls8 ERG136 | allfirefighter.com/hazmat/un/3301SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/3301

Related UN Numbers in Class 8

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 3301

Extremely flammable; will ignite itself if exposed to air. Burns rapidly, releasing dense, white, irritating fumes. Substance may be transported in a molten form. May re-ignite after fire is extinguished. Corrosives in contact with metals may evolve flammable hydrogen gas. Containers may explode when heated. Fire will produce irritating, corrosive and/or toxic gases. TOXIC and/or CORROSIVE; ingestion of substance or inhalation of decomposition products will cause

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Stay upwind, uphill and/or upstream. Keep unauthorized personnel away.

Level A or B with SCBA required; full chemical-resistant suit; avoid all contact due to corrosive and self-heating hazards

Water reactivity: May react with water generating heat and corrosive fumes; avoid water contact. Recommended extinguishing: Dry chemical, CO2, sand; do not use water or foam due to corrosive nature and self-heating properties.

ERG Guide 136 recommendation: ERG 136: isolate spill area at least 25-50m in all directions; if fire or large spill, isolate 800m and evacuate downwind

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 136 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.