☣️ UN 1572 • CLASS 6

UN 1572 — Cacodylic acid

Placard: Toxic. ERG Guide 151. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement

UN 1572 Quick Details

UN 1572
Product name: Cacodylic acid
DOT Class: 6
Placard type: Toxic
ERG Guide: 151 (check current ERG)
Initial isolation: ERG 151: isolate 25m all directions initially; spill: 25m day/50m night; fire: 800m all directions, consider evacuation

Common Hazards of UN 1572

  • Highly toxic, may be fatal if inhaled, ingested or absorbed through skin.
  • Avoid any skin contact.
  • Fire may produce irritating, corrosive and/or toxic gases.
  • Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
  • Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
  • Containers may explode when heated.
  • Runoff may pollute waterways.

Chemical Identity & Physical Properties

Also known asDimethylarsinic acidHydroxydimethylarsine oxideAgent BluePhytarArsan
CAS Number75-60-5
AppearanceWhite crystalline solid with a garlic-like odor. Hygroscopic and readily absorbs moisture from air.
Flash PointNot applicable (non-flammable solid)
Boiling Point200C (392F) with decomposition
Vapor DensityNot applicable (solid)
Water ReactivitySoluble in water, no violent reaction but produces toxic solutions
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1572

Extinguishing Media

Dry chemical, sand, CO2 suitable; water spray may be used to keep containers cool

PPE Requirements

⚠️ Level A required for spills; SCBA mandatory; chemical-resistant suit, gloves, and boots; avoid all skin contact due to severe toxicity

Isolation & Evacuation

ERG 151: isolate 25m all directions initially; spill: 25m day/50m night; fire: 800m all directions, consider evacuation
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 151).

First Actions for a UN 1572 Incident

  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement

📋 Copy & Share Field Card

UN 1572 — Cacodylic acid
HAZMAT RADIO NOTE — UN 1572 Product: Cacodylic acid Class 6 / Toxic / ERG 151 PPE: Level A required for spills; SCBA mandatory; chemical-resistant suit, gloves, and boots; avoid all skin contact due to severe toxicity ISOLATION: ERG 151: isolate 25m all directions initially; spill: 25m day/50m night; fire: 800m all directions, consider evacuation ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1572 — Cacodylic acid Class: 6 | Placard: Toxic | ERG Guide: 151 Appearance: White crystalline solid with a garlic-like odor. Hygroscopic and readily absorbs moisture from air. Water Reactivity: Soluble in water, no violent reaction but produces toxic solutions Extinguishing: Dry chemical, sand, CO2 suitable; water spray may be used to keep containers cool PPE: Level A required for spills; SCBA mandatory; chemical-resistant suit, gloves, and boots; avoid all skin contact due to severe toxicity Isolation: ERG 151: isolate 25m all directions initially; spill: 25m day/50m night; fire: 800m all directions, consider evacuation — Key Hazards — • Highly toxic, may be fatal if inhaled, ingested or absorbed through skin. • Avoid any skin contact. • Fire may produce irritating, corrosive and/or toxic gases. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters SOURCE: allfirefighter.com/hazmat/un/1572 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN1572 Cacodylic acid Cls6 ERG151 | ERG 151: isolate 25m all directions initially; spill: 25m day/50m night; fire: 8 | allfirefighter.com/hazmat/un/1572SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/1572

Related UN Numbers in Class 6

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1572

Highly toxic, may be fatal if inhaled, ingested or absorbed through skin. Avoid any skin contact. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive Containers may explode when heated. Runoff may pollute waterways.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level A required for spills; SCBA mandatory; chemical-resistant suit, gloves, and boots; avoid all skin contact due to severe toxicity

Water reactivity: Soluble in water, no violent reaction but produces toxic solutions. Recommended extinguishing: Dry chemical, sand, CO2 suitable; water spray may be used to keep containers cool.

ERG Guide 151 recommendation: ERG 151: isolate 25m all directions initially; spill: 25m day/50m night; fire: 800m all directions, consider evacuation

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 151 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.