☣️ UN 2317 • CLASS 6
UN 2317 — Sodium cuprocyanide, solution
Placard: Toxic. ERG Guide 157. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
UN 2317 Quick Details
UN 2317
Product name: Sodium cuprocyanide, solution
DOT Class: 6
Placard type: Toxic
ERG Guide: 157 (check current ERG)
Initial isolation: ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind
Common Hazards of UN 2317
- TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance
- Reaction with water or moist air may release toxic, corrosive or flammable gases.
- Reaction with water may generate much heat that will increase the concentration of fumes in the air.
- Fire will produce irritating, corrosive and/or toxic gases.
- Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
- Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
- UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above
- Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).
Chemical Identity & Physical Properties
| Also known as | Cuprous sodium cyanide solutionCopper sodium cyanide solutionSodium copper(I) cyanide solutionCupronatriumcyanid solution |
| Appearance | Clear to pale yellow aqueous solution with a faint almond-like odor characteristic of cyanide compounds. Liquid at room temperature. |
| Flash Point | Not applicable (aqueous solution, non-flammable) |
| Boiling Point | Approximately 100C (212F), similar to water |
| Vapor Density | Not applicable (aqueous solution) |
| Water Reactivity | Already in aqueous solution; dilution with water may release hydrogen cyanide gas, especially if acidic conditions develop |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Fireground Response Guidance — UN 2317
Extinguishing Media
Water spray to control vapors, CO2, dry chemical; avoid acidic agents that could liberate HCN gas
PPE Requirements
⚠️ Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots
Isolation & Evacuation
ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 157).
First Actions for a UN 2317 Incident
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
- For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
- For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share Field Card
UN 2317 — Sodium cuprocyanide, solutionHAZMAT RADIO NOTE — UN 2317
Product: Sodium cuprocyanide, solution
Class 6 / Toxic / ERG 157
PPE: Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots
ISOLATION: ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 2317 — Sodium cuprocyanide, solution
Class: 6 | Placard: Toxic | ERG Guide: 157
Appearance: Clear to pale yellow aqueous solution with a faint almond-like odor characteristic of cyanide compounds. Liquid at room temperature.
Water Reactivity: Already in aqueous solution; dilution with water may release hydrogen cyanide gas, especially if acidic conditions develop
Extinguishing: Water spray to control vapors, CO2, dry chemical; avoid acidic agents that could liberate HCN gas
PPE: Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots
Isolation: ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind
— Key Hazards —
• TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance
• Reaction with water or moist air may release toxic, corrosive or flammable gases.
• Reaction with water may generate much heat that will increase the concentration of fumes in the air.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Ventilate closed spaces before entering, but only if properly trained and equipped.
SOURCE: allfirefighter.com/hazmat/un/2317 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN2317 Sodium cuprocyanide, solution Cls6 ERG157 | allfirefighter.com/hazmat/un/2317SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions.
Page: https://allfirefighter.com/hazmat/un/2317
Advertisement
Frequently Asked Questions about UN 2317
TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance Reaction with water or moist air may release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots
Water reactivity: Already in aqueous solution; dilution with water may release hydrogen cyanide gas, especially if acidic conditions develop. Recommended extinguishing: Water spray to control vapors, CO2, dry chemical; avoid acidic agents that could liberate HCN gas.
ERG Guide 157 recommendation: ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 157 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles.
This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.