☣️ UN 2317 • CLASS 6

Sodium cuprocyanide, solution

Placard: Toxic. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 2317
Class: 6
Placard type: Toxic
ERG: Guide 157 (check current ERG)
Isolation: ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind
Chemical & Response Details
Also known asCuprous sodium cyanide solutionCopper sodium cyanide solutionSodium copper(I) cyanide solutionCupronatriumcyanid solution
AppearanceClear to pale yellow aqueous solution with a faint almond-like odor characteristic of cyanide compounds. Liquid at room temperature.
Flash PointNot applicable (aqueous solution, non-flammable)
Boiling PointApproximately 100C (212F), similar to water
Vapor DensityNot applicable (aqueous solution)
Water ReactivityAlready in aqueous solution; dilution with water may release hydrogen cyanide gas, especially if acidic conditions develop
ExtinguishingWater spray to control vapors, CO2, dry chemical; avoid acidic agents that could liberate HCN gas
PPE⚠️ Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots
IsolationERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance
  • Reaction with water or moist air may release toxic, corrosive or flammable gases.
  • Reaction with water may generate much heat that will increase the concentration of fumes in the air.
  • Fire will produce irritating, corrosive and/or toxic gases.
  • Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
  • Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
  • UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above
  • Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).
First actions (field-minded)
  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 2317 — Sodium cuprocyanide, solution
HAZMAT RADIO NOTE — UN 2317 Product: Sodium cuprocyanide, solution Class 6 / Toxic / ERG 157 PPE: Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots ISOLATION: ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2317 — Sodium cuprocyanide, solution Class: 6 | Placard: Toxic | ERG Guide: 157 Appearance: Clear to pale yellow aqueous solution with a faint almond-like odor characteristic of cyanide compounds. Liquid at room temperature. Water Reactivity: Already in aqueous solution; dilution with water may release hydrogen cyanide gas, especially if acidic conditions develop Extinguishing: Water spray to control vapors, CO2, dry chemical; avoid acidic agents that could liberate HCN gas PPE: Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots Isolation: ERG 157: isolate spill 25-50m all directions; evacuate immediate area; if tank/rail car involved in fire, isolate 800m all directions and consider evacuation 1600m downwind — Key Hazards — • TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance • Reaction with water or moist air may release toxic, corrosive or flammable gases. • Reaction with water may generate much heat that will increase the concentration of fumes in the air. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/2317 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN2317 Sodium cuprocyanide, solution Cls6 ERG157 | allfirefighter.com/hazmat/un/2317SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2317
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

TOXIC and/or CORROSIVE; inhalation, ingestion or contact (skin, eyes) with vapors, dusts or substance Reaction with water or moist air may release toxic, corrosive or flammable gases. Reaction with water may generate much heat that will increase the concentration of fumes in the air. Fire will produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive UN1802, UN2032, UN3084, UN3093, UN1796 (above 50%), UN1826 (above 50%), and UN2031 (above Vapors may accumulate in confined areas (basement, tanks, hopper/tank cars, etc.).

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum with full face respirator; Level A if concentrations unknown or confined space; SCBA required; chemical-resistant suit, gloves, boots

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 157 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.