☣️ UN 2401 • CLASS 8

Piperidine

Placard: Corrosive. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 2401
Class: 8
Placard type: Corrosive
ERG: Guide 132 (check current ERG)
Isolation: ERG 132: isolate spill area 50m all directions; if tank/rail car involved in fire, isolate 800m all directions
Chemical & Response Details
Also known asHexahydropyridinePentamethyleneamineAzacyclohexaneCyclopentylamine
CAS Number110-89-4
AppearanceColorless to pale yellow liquid with a strong, unpleasant ammonia-like or pepper-like odor. Fuming liquid at room temperature.
Flash Point16C (61F)
Boiling Point106C (223F)
Vapor Density2.9 (heavier than air)
Water ReactivitySoluble in water; may generate heat on mixing but no violent reaction
ExtinguishingAlcohol-resistant foam, CO2, dry chemical, water spray
PPE⚠️ Level B minimum; SCBA required; chemical-resistant suit recommended due to corrosive nature
IsolationERG 132: isolate spill area 50m all directions; if tank/rail car involved in fire, isolate 800m all directions
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • Flammable/combustible material.
  • May be ignited by heat, sparks or flames.
  • Vapors may form explosive mixtures with air.
  • Vapors may travel to source of ignition and flash back.
  • Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
  • Vapor explosion hazard indoors, outdoors or in sewers.
  • Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
  • Runoff to sewer may create fire or explosion hazard.
First actions (field-minded)
  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 2401 — Piperidine
HAZMAT RADIO NOTE — UN 2401 Product: Piperidine Class 8 / Corrosive / ERG 132 PPE: Level B minimum; SCBA required; chemical-resistant suit recommended due to corrosive nature ISOLATION: ERG 132: isolate spill area 50m all directions; if tank/rail car involved in fire, isolate 800m all directions ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2401 — Piperidine Class: 8 | Placard: Corrosive | ERG Guide: 132 Appearance: Colorless to pale yellow liquid with a strong, unpleasant ammonia-like or pepper-like odor. Fuming liquid at room temperature. Water Reactivity: Soluble in water; may generate heat on mixing but no violent reaction Extinguishing: Alcohol-resistant foam, CO2, dry chemical, water spray PPE: Level B minimum; SCBA required; chemical-resistant suit recommended due to corrosive nature Isolation: ERG 132: isolate spill area 50m all directions; if tank/rail car involved in fire, isolate 800m all directions — Key Hazards — • Flammable/combustible material. • May be ignited by heat, sparks or flames. • Vapors may form explosive mixtures with air. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/2401 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN2401 Piperidine Cls8 ERG132 | ERG 132: isolate spill area 50m all directions; if tank/rail car involved in fir | allfirefighter.com/hazmat/un/2401SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2401
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

Flammable/combustible material. May be ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard.

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level B minimum; SCBA required; chemical-resistant suit recommended due to corrosive nature

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 132 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.