☣️ UN 2863 • CLASS 6
Sodium ammonium vanadate
Placard: Toxic. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 2863
Class: 6
Placard type: Toxic
ERG: Guide 154 (check current ERG)
Isolation: ERG 154: isolate spill 25m all directions; if fire or large spill, isolate 800m downwind during day, consider evacuation
Chemical & Response Details
| Also known as | Ammonium sodium vanadateAmmonium metavanadate sodium saltSodium ammonium metavanadateVanadate, ammonium sodium salt |
| CAS Number | 13820-40-1 |
| Appearance | White to pale yellow crystalline powder or granular solid, odorless, stable at room temperature. |
| Flash Point | Not applicable (inorganic oxidizing solid) |
| Boiling Point | Not applicable (decomposes before boiling) |
| Vapor Density | Not applicable (solid) |
| Water Reactivity | Soluble in water with no violent reaction; releases toxic vanadium compounds in solution |
| Extinguishing | Dry chemical, soda ash, lime; avoid generating dust; water spray for cooling only |
| PPE | ⚠️ Level B minimum; full chemical-resistant suit, SCBA required; prevent all skin contact due to severe toxicity and corrosive properties |
| Isolation | ERG 154: isolate spill 25m all directions; if fire or large spill, isolate 800m downwind during day, consider evacuation |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
- TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury
- Contact with molten substance may cause severe burns to skin and eyes.
- Avoid any skin contact.
- Fire may produce irritating, corrosive and/or toxic gases.
- Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
- Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
- Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.).
- Corrosives in contact with metals may evolve flammable hydrogen gas.
First actions (field-minded)
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
- For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
- For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 2863 — Sodium ammonium vanadate HAZMAT RADIO NOTE — UN 2863
Product: Sodium ammonium vanadate
Class 6 / Toxic / ERG 154
PPE: Level B minimum; full chemical-resistant suit, SCBA required; prevent all skin contact due to severe toxicity and corrosive properties
ISOLATION: ERG 154: isolate spill 25m all directions; if fire or large spill, isolate 800m downwind during day, consider evacuation
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 2863 — Sodium ammonium vanadate
Class: 6 | Placard: Toxic | ERG Guide: 154
Appearance: White to pale yellow crystalline powder or granular solid, odorless, stable at room temperature.
Water Reactivity: Soluble in water with no violent reaction; releases toxic vanadium compounds in solution
Extinguishing: Dry chemical, soda ash, lime; avoid generating dust; water spray for cooling only
PPE: Level B minimum; full chemical-resistant suit, SCBA required; prevent all skin contact due to severe toxicity and corrosive properties
Isolation: ERG 154: isolate spill 25m all directions; if fire or large spill, isolate 800m downwind during day, consider evacuation
— Key Hazards —
• TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury
• Contact with molten substance may cause severe burns to skin and eyes.
• Avoid any skin contact.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Ventilate closed spaces before entering, but only if properly trained and equipped.
SOURCE: allfirefighter.com/hazmat/un/2863 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN2863 Sodium ammonium vanadate Cls6 ERG154 | allfirefighter.com/hazmat/un/2863SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/2863
Advertisement
FAQ
TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive Some are oxidizers and may ignite combustibles (wood, paper, oil, clothing, etc.). Corrosives in contact with metals may evolve flammable hydrogen gas.
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level B minimum; full chemical-resistant suit, SCBA required; prevent all skin contact due to severe toxicity and corrosive properties
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 154 and your department SOP/SOG for incident-specific protective actions.