☣️ UN 3477 • CLASS 8

Fuel cell cartridges contained in equipment, containing corrosive substances

Placard: Corrosive. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
Quick details
UN 3477
Class: 8
Placard type: Corrosive
ERG: Guide 153 (check current ERG)
Isolation: ERG 153: Small spill isolate 25m all directions; large spill/fire isolate 50m, consider evacuation 300m downwind
Chemical & Response Details
Also known asFuel cell cartridge assembliesCorrosive fuel cell devicesFuel cell power units with corrosive electrolytePortable fuel cell cartridges
AppearanceSealed cartridge devices containing liquid or gel corrosive electrolyte (typically alkaline or acidic solutions). Physical state varies by design; cartridges are typically plastic or metal assemblies at room temperature.
Flash PointNot applicable (sealed device containing corrosive electrolyte)
Boiling PointNot applicable (sealed device; electrolyte properties vary)
Vapor DensityNot applicable (sealed solid device)
Water ReactivityElectrolyte may be alkaline (corrosive) or acidic (corrosive); avoid contact with leaking contents
ExtinguishingDry chemical, CO2, water spray for fire control; avoid direct contact with leaked corrosive electrolyte
PPE⚠️ Level C minimum for intact cartridges; Level B with SCBA if leaking or damaged with vapor release; chemical-resistant gloves and face shield required
IsolationERG 153: Small spill isolate 25m all directions; large spill/fire isolate 50m, consider evacuation 300m downwind
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Common hazards (high level)
  • TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury
  • Methyl bromoacetate (UN2643) is an eye irritant/lachrymator (causes flow of tears).
  • Contact with molten substance may cause severe burns to skin and eyes.
  • Avoid any skin contact.
  • Fire may produce irritating, corrosive and/or toxic gases.
  • Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
  • Combustible material: may burn but does not ignite readily.
  • When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion
First actions (field-minded)
  • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Ventilate closed spaces before entering, but only if properly trained and equipped.
  • Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
  • For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
  • For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share
UN 3477 — Fuel cell cartridges contained in equipm
HAZMAT RADIO NOTE — UN 3477 Product: Fuel cell cartridges contained in equipment, containing corrosive substances Class 8 / Corrosive / ERG 153 PPE: Level C minimum for intact cartridges; Level B with SCBA if leaking or damaged with vapor release; chemical-resistant gloves and face shield required ISOLATION: ERG 153: Small spill isolate 25m all directions; large spill/fire isolate 50m, consider evacuation 300m downwind ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 3477 — Fuel cell cartridges contained in equipment, containing corrosive substances Class: 8 | Placard: Corrosive | ERG Guide: 153 Appearance: Sealed cartridge devices containing liquid or gel corrosive electrolyte (typically alkaline or acidic solutions). Physical state varies by design; cartridges are typically plastic or metal assemblies at room temperature. Water Reactivity: Electrolyte may be alkaline (corrosive) or acidic (corrosive); avoid contact with leaking contents Extinguishing: Dry chemical, CO2, water spray for fire control; avoid direct contact with leaked corrosive electrolyte PPE: Level C minimum for intact cartridges; Level B with SCBA if leaking or damaged with vapor release; chemical-resistant gloves and face shield required Isolation: ERG 153: Small spill isolate 25m all directions; large spill/fire isolate 50m, consider evacuation 300m downwind — Key Hazards — • TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury • Methyl bromoacetate (UN2643) is an eye irritant/lachrymator (causes flow of tears). • Contact with molten substance may cause severe burns to skin and eyes. — First Actions — • CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Ventilate closed spaces before entering, but only if properly trained and equipped. SOURCE: allfirefighter.com/hazmat/un/3477 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.

SMS (short)
UN3477 Fuel cell cartridges contained in equipment, containing corrosive substances Cls8 ERG153 | allfirefighter.com/hazmat/un/3477SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/3477
Related UN numbers (same class)
Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

FAQ

TOXIC and/or CORROSIVE; inhalation, ingestion or skin contact with material may cause severe injury Methyl bromoacetate (UN2643) is an eye irritant/lachrymator (causes flow of tears). Contact with molten substance may cause severe burns to skin and eyes. Avoid any skin contact. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Combustible material: may burn but does not ignite readily. When heated, vapors may form explosive mixtures with air: indoors, outdoors and sewers explosion

CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.

Level C minimum for intact cartridges; Level B with SCBA if leaking or damaged with vapor release; chemical-resistant gloves and face shield required

No. This is a training/quick-reference aid only. Always consult the current ERG Guide 153 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.