☣️ UN 1769 • CLASS 8

UN 1769 — Diphenyldichlorosilane

Placard: Corrosive. ERG Guide 156. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1769 is Diphenyldichlorosilane, a corrosive hazardous material assigned to ERG Guide 156. Responders should verify the exact product with shipping papers, container markings and SDS before close action.

Hazard overview: UN 1769 presents corrosive exposure hazards and may create toxic/corrosive gases or runoff in fire or incompatible contact. Use ERG, SDS and incident command to set isolation, PPE and control actions.

Response guidance: For a UN 1769 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 156. Establish incident command, isolate the area, stay upwind, prevent incompatible contact, control runoff and choose entry or fire-control actions based on monitoring, SDS and local SOP.

Firefighter training notes: Training for UN 1769 should emphasize corrosive exposure routes, water or oxidizer incompatibility where applicable, air monitoring, PPE selection, decontamination and runoff containment. Use ERG 156, SDS and local SOP.

Regulatory context: Diphenyldichlorosilane is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, pesticide/waste handling where applicable, storage and environmental requirements may vary by formulation, concentration, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Diphenyldichlorosilane should be stored in tightly closed compatible containers in a secure, cool, dry, well-ventilated hazardous-material area according to SDS and local procedures.

Advertisement

UN 1769 Quick Details

UN 1769
Product name: Diphenyldichlorosilane
DOT Class: 8
Placard type: Corrosive
ERG Guide: 156 (check current ERG)
Initial isolation: ERG 156: Isolate spill 25-50m all directions. Evacuate immediate area if fire or large spill. Toxic/corrosive vapors may travel considerable distance.

Common Hazards of UN 1769

  • CORROSIVE material; inhalation, ingestion or skin/eye contact may cause severe injury.
  • Fire may produce irritating, corrosive and/or toxic gases.
  • Runoff may be corrosive and may pollute waterways.
  • Containers may rupture or fail when heated.
  • Specific hazards depend on the exact product, concentration and SDS.

Chemical Identity & Physical Properties

Colorless to pale yellow liquid with a pungent, acrid odor. Fuming liquid that reacts with moisture in air.

Also known asDichlorodiphenylsilaneDiphenylsilicon dichlorideSilane, dichlorodiphenyl-
CAS Number80-10-4
AppearanceColorless to pale yellow liquid with a pungent, acrid odor. Fuming liquid that reacts with moisture in air.
Flash Point132C (270F)
Boiling Point305C (581F)
Vapor Density8.4 (much heavier than air)
Water ReactivityReacts violently with water, releasing HCl gas and heat. Do not use water directly on material.
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1769

Extinguishing Media

Use extinguishing agents appropriate for the surrounding fire and SDS. Water spray may cool containers or reduce vapors only when runoff can be controlled as corrosive/toxic contamination.

PPE Requirements

⚠️ Level B minimum with full face SCBA. Chemical-resistant suit required due to corrosive vapors and water reactivity.

Use positive-pressure SCBA for vapor, mist, dust, fire or confined-space exposure. Chemical-resistant gloves, boots, eye/face protection and protective clothing should be selected from SDS.

Isolation & Evacuation

ERG 156: Isolate spill 25-50m all directions. Evacuate immediate area if fire or large spill. Toxic/corrosive vapors may travel considerable distance.
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 156).

First Actions for a UN 1769 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid breathing vapors, fumes, dust, mist or spray and avoid skin or eye contact.
  • Do not touch or walk through spilled material unless properly trained and wearing appropriate protective equipment.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the spill or leak area and expand the perimeter if vapor, dust, fire involvement, water reaction or unknown concentration is present.
  • Use ERG Guide 156, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 1769 — Diphenyldichlorosilane
HAZMAT RADIO NOTE — UN 1769 Product: Diphenyldichlorosilane Class 8 / Corrosive / ERG 156 PPE: Level B minimum with full face SCBA. Chemical-resistant suit required due to corrosive vapors and water reactivity. ISOLATION: ERG 156: Isolate spill 25-50m all directions. Evacuate immediate area if fire or large spill. Toxic/corrosive vapors may travel considerable distance. ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1769 — Diphenyldichlorosilane Class: 8 | Placard: Corrosive | ERG Guide: 156 Appearance: Colorless to pale yellow liquid with a pungent, acrid odor. Fuming liquid that reacts with moisture in air. Water Reactivity: Reacts violently with water, releasing HCl gas and heat. Do not use water directly on material. Extinguishing: Use extinguishing agents appropriate for the surrounding fire and SDS. Water spray may cool containers or reduce vapors only when runoff can be controlled as corrosive/toxic contamination. PPE: Level B minimum with full face SCBA. Chemical-resistant suit required due to corrosive vapors and water reactivity. Isolation: ERG 156: Isolate spill 25-50m all directions. Evacuate immediate area if fire or large spill. Toxic/corrosive vapors may travel considerable distance. — Key Hazards — • CORROSIVE material; inhalation, ingestion or skin/eye contact may cause severe injury. • Fire may produce irritating, corrosive and/or toxic gases. • Runoff may be corrosive and may pollute waterways. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid breathing vapors, fumes, dust, mist or spray and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/diphenyldichlorosilane-un-1769 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1769 Diphenyldichlorosilane Cls8 ERG156 | allfirefighter.com/hazmat/un/diphenyldichlorosilane-un-1769SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/diphenyldichlorosilane-un-1769

Related UN Numbers in Class 8

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1769

UN 1769 is Diphenyldichlorosilane, a hazardous material assigned to ERG Guide 156.

Flammability depends on the exact material and SDS; corrosive exposure is the main concern.

ERG Guide 156 applies to UN 1769 for initial isolation, protective actions and first response guidance.

UN 1769 presents corrosive exposure hazards and may create toxic/corrosive gases or runoff in fire or incompatible contact. Use ERG, SDS and incident command to set isolation, PPE and control actions.

Use positive-pressure SCBA for vapor, mist, dust, fire or confined-space exposure. Chemical-resistant gloves, boots, eye/face protection and protective clothing should be selected from SDS.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.