UN 3484 — Hydrazine aqueous solution, flammable, with more than 37% hydrazine
Placard: Corrosive. ERG Guide 132. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
UN 3484 At a Glance
UN 3484 (Hydrazine aqueous solution, flammable, with more than 37% hydrazine) is listed as DOT Class 8 Corrosive and is assigned to ERG Guide 132. Use this page to review placard data, common hazards, PPE notes, isolation context, first actions, and related UN numbers.
UN 3484 covers aqueous hydrazine solution with more than 37% hydrazine, a reactive flammable and corrosive liquid.
Hazard overview: Hydrazine vapors can ignite, form explosive mixtures, and cause severe inhalation, skin, and eye hazards. The liquid is corrosive and toxic.
Response guidance: Isolate the area, remove ignition sources, ventilate from upwind, and use alcohol-resistant foam, dry chemical, or CO2. Cool containers with water spray.
UN 3484 Quick Details
Common Hazards of UN 3484
- Flammable/combustible material.
- May be ignited by heat, sparks or flames.
- Vapors may form explosive mixtures with air.
- Vapors may travel to source of ignition and flash back.
- Most vapors are heavier than air. They will spread along the ground and collect in low or confined areas
- Vapor explosion hazard indoors, outdoors or in sewers.
- Those substances designated with a (P) may polymerize explosively when heated or involved in a fire.
- Runoff to sewer may create fire or explosion hazard.
Chemical Identity & Physical Properties
Hydrazine aqueous solution is a colorless to pale yellow, fuming liquid with an ammonia-like odor.
| Also known as | Hydrazine hydrateDiamineHydrazine monohydrateLevoxine |
| CAS Number | 302-01-2 |
| Appearance | Colorless to pale yellow, fuming liquid with an ammonia-like odor. Hygroscopic and highly reactive. Fumes in moist air. |
| Flash Point | 38C (100F) for 64% solution; varies with concentration |
| Boiling Point | 113.5C (236F) for pure hydrazine hydrate |
| Vapor Density | 1.1 (heavier than air) |
| Water Reactivity | Miscible with water; dilution generates heat but does not react violently |
Fireground Response Guidance — UN 3484
Extinguishing Media
PPE Requirements
Level A is recommended for concentrated leaks or unknown exposure. SCBA and full chemical-resistant suit are required for significant response.
Isolation & Evacuation
First Actions for a UN 3484 Incident
- CALL 911. Then call the emergency response number on the shipping paper, if available.
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Ventilate closed spaces before entering, but only if properly trained and equipped.
- Isolate spill or leak area for at least 50 meters (150 feet) in all directions.
- For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
- For non-highlighted materials, increase the downwind precautionary distance as conditions require.
📋 Copy & Share Field Card
UN 3484 — Hydrazine aqueous solution, flammable, wUse for: Quick radio or face-to-face size-up. Short, structured, field-ready.
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.
Use for: Quick text to command or incoming units. Fits in a single SMS.