☣️ UN 2444 • CLASS 8

UN 2444 — Vanadium tetrachloride

Placard: Corrosive. ERG Guide 137. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2444 is Vanadium tetrachloride, a toxic corrosive vanadium chloride liquid assigned to ERG Guide 137. Moisture can trigger strong fuming and acid runoff.

Hazard overview: TOXIC and CORROSIVE vanadium chloride/oxychloride liquid; vapor or liquid contact may cause severe injury. Reacts vigorously with water or moist air, releasing hydrogen chloride and heat. Fumes strongly in moist air and can produce acidic/corrosive runoff.

Response guidance: For UN 2444, isolate the spill, stay upwind and use SCBA with chemical protection. Control moisture contact, contain acidic runoff and use dry compatible agents under SDS and ERG 137 guidance.

Firefighter training notes: Training for UN 2444 should emphasize water-reactive corrosive fuming, HCl hazards, dry-agent selection, Level A/B decisions, decontamination and acidic runoff control. Use ERG 137, SDS and local SOP.

Regulatory context: Vanadium tetrachloride is regulated as a hazardous material for transport and emergency response. Storage, exposure, spill reporting, waste and fire-code duties depend on quantity, concentration and jurisdiction; verify shipping papers, SDS and local authority requirements.

Storage & handling: Vanadium tetrachloride should be stored dry in tightly closed compatible containers away from water, moisture, bases, oxidizers/reducing agents where incompatible, heat and unauthorized access. Provide secondary containment.

Advertisement

UN 2444 Quick Details

UN 2444
Product name: Vanadium tetrachloride
DOT Class: 8
Placard type: Corrosive
ERG Guide: 137 (check current ERG)
Initial isolation: ERG 137: Isolate spill 25-50m all directions. For large spills isolate 800m downwind. Evacuate immediate area if containers exposed to fire.

Common Hazards of UN 2444

  • TOXIC and CORROSIVE vanadium chloride/oxychloride liquid; vapor or liquid contact may cause severe injury.
  • Reacts vigorously with water or moist air, releasing hydrogen chloride and heat.
  • Fumes strongly in moist air and can produce acidic/corrosive runoff.
  • Non-combustible or combustible behavior depends on product, but fire produces toxic/corrosive fumes.
  • Exposure may involve vanadium toxicity plus acid burns.
  • Containers may rupture when heated or contaminated with water.
  • Avoid direct water contact with released product unless specialist guidance approves.

Chemical Identity & Physical Properties

Reddish-brown fuming liquid with a pungent, irritating odor. Reacts vigorously with moisture in air producing corrosive fumes.

Also known asVanadium(IV) chlorideTetrachlorovanadiumVanadium chloride
CAS Number7632-51-1
AppearanceReddish-brown fuming liquid with a pungent, irritating odor. Reacts vigorously with moisture in air producing corrosive fumes.
Flash PointNot applicable (non-flammable but supports combustion)
Boiling Point154C (309F)
Vapor Density6.7 (much heavier than air)
Water ReactivityReacts violently with water producing heat, hydrochloric acid, and vanadium oxychloride fumes. Do not use water directly on material.
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2444

Extinguishing Media

Use dry chemical, CO2, dry sand or SDS-approved media. Water spray may cool exposed containers from a protected distance, but direct water can increase corrosive fuming.

PPE Requirements

⚠️ Level A or B required; full-face SCBA, chemical-resistant suit, butyl rubber gloves. Avoid all contact with vapors and liquid.

Use positive-pressure SCBA and chemical-resistant protective clothing. Level A may be needed for heavy vapor, fuming, splash risk or unknown concentrations.

Isolation & Evacuation

ERG 137: Isolate spill 25-50m all directions. For large spills isolate 800m downwind. Evacuate immediate area if containers exposed to fire.
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 137).

First Actions for a UN 2444 Incident

  • Call 911 and the emergency response number on the shipping paper, if available.
  • Keep unauthorized personnel away and establish incident command.
  • Stay upwind, uphill and upstream.
  • Avoid breathing vapor, dust, mist, smoke or fumes and avoid skin or eye contact.
  • Keep water contact controlled because moisture can increase heat release, corrosive fuming or ignition.
  • Do not touch damaged containers or spilled material without proper training and PPE.
  • Ventilate confined spaces only after monitoring and only if properly trained and equipped.
  • Use ERG Guide 137, SDS, shipping papers and monitoring to set isolation, evacuation and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 2444 — Vanadium tetrachloride
HAZMAT RADIO NOTE — UN 2444 Product: Vanadium tetrachloride Class 8 / Corrosive / ERG 137 PPE: Level A or B required; full-face SCBA, chemical-resistant suit, butyl rubber gloves. Avoid all contact with vapors and liquid. ISOLATION: ERG 137: Isolate spill 25-50m all directions. For large spills isolate 800m downwind. Evacuate immediate area if containers exposed to fire. ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2444 — Vanadium tetrachloride Class: 8 | Placard: Corrosive | ERG Guide: 137 Appearance: Reddish-brown fuming liquid with a pungent, irritating odor. Reacts vigorously with moisture in air producing corrosive fumes. Water Reactivity: Reacts violently with water producing heat, hydrochloric acid, and vanadium oxychloride fumes. Do not use water directly on material. Extinguishing: Use dry chemical, CO2, dry sand or SDS-approved media. Water spray may cool exposed containers from a protected distance, but direct water can increase corrosive fuming. PPE: Level A or B required; full-face SCBA, chemical-resistant suit, butyl rubber gloves. Avoid all contact with vapors and liquid. Isolation: ERG 137: Isolate spill 25-50m all directions. For large spills isolate 800m downwind. Evacuate immediate area if containers exposed to fire. — Key Hazards — • TOXIC and CORROSIVE vanadium chloride/oxychloride liquid; vapor or liquid contact may cause severe injury. • Reacts vigorously with water or moist air, releasing hydrogen chloride and heat. • Fumes strongly in moist air and can produce acidic/corrosive runoff. — First Actions — • Call 911 and the emergency response number on the shipping paper, if available. • Keep unauthorized personnel away and establish incident command. • Stay upwind, uphill and upstream. • Avoid breathing vapor, dust, mist, smoke or fumes and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/vanadium-tetrachloride-un-2444 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2444 Vanadium tetrachloride Cls8 ERG137 | allfirefighter.com/hazmat/un/vanadium-tetrachloride-un-2444SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/vanadium-tetrachloride-un-2444

Related UN Numbers in Class 8

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2444

UN 2444 is Vanadium tetrachloride, assigned to ERG Guide 137.

No. Vanadium tetrachloride is not normally flammable, but heat or moisture can produce toxic/corrosive fumes.

TOXIC and CORROSIVE vanadium chloride/oxychloride liquid; vapor or liquid contact may cause severe injury. Reacts vigorously with water or moist air, releasing hydrogen chloride and heat. Fumes strongly in moist air and can produce acidic/corrosive runoff.

Use positive-pressure SCBA and chemical-resistant protective clothing. Level A may be needed for heavy vapor, fuming, splash risk or unknown concentrations.

Use dry chemical, CO2, dry sand or SDS-approved media. Water spray may cool exposed containers from a protected distance, but direct water can increase corrosive fuming.

Moisture can produce heat, corrosive acidic solution or toxic/corrosive fumes; water use should be controlled by incident command.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.