☣️ UN 1618 • CLASS 6
UN 1618 — Lead arsenites
Placard: Toxic. ERG Guide 151. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.
🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.
Advertisement
UN 1618 Quick Details
UN 1618
Product name: Lead arsenites
DOT Class: 6
Placard type: Toxic
ERG Guide: 151 (check current ERG)
Initial isolation: ERG 151: Isolate spill area at least 25m in all directions; if large spill or fire involved, isolate 800m and consider evacuation
Common Hazards of UN 1618
- Highly toxic, may be fatal if inhaled, ingested or absorbed through skin.
- Avoid any skin contact.
- Fire may produce irritating, corrosive and/or toxic gases.
- Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental
- Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive
- Containers may explode when heated.
- Runoff may pollute waterways.
Chemical Identity & Physical Properties
| Also known as | Lead arseniteArsenious acid lead saltLead(II) arsenitePlumbous arsenite |
| Appearance | White to grayish-white powder or crystalline solid. Odorless. Stable at room temperature as a solid. |
| Flash Point | Not applicable (non-combustible inorganic solid) |
| Boiling Point | Not applicable (decomposes before boiling) |
| Vapor Density | Not applicable (solid material) |
| Water Reactivity | Slightly soluble in water; releases toxic arsenic compounds upon dissolution |
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.
Fireground Response Guidance — UN 1618
Extinguishing Media
Water spray, dry chemical, CO2; foam not typically required for non-combustible material
PPE Requirements
⚠️ Level A or B required; full-face SCBA, chemical-resistant suit, double gloves; avoid any skin contact due to extreme toxicity
Isolation & Evacuation
ERG 151: Isolate spill area at least 25m in all directions; if large spill or fire involved, isolate 800m and consider evacuation
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 151).
First Actions for a UN 1618 Incident
- CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
- Keep unauthorized personnel away.
- Stay upwind, uphill and/or upstream.
- Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
- For highlighted materials: see Table 1 - Initial Isolation and Protective Action Distances.
- For non-highlighted materials: increase the immediate precautionary measure distance, in the downwind
Advertisement
📋 Copy & Share Field Card
UN 1618 — Lead arsenitesHAZMAT RADIO NOTE — UN 1618
Product: Lead arsenites
Class 6 / Toxic / ERG 151
PPE: Level A or B required; full-face SCBA, chemical-resistant suit, double gloves; avoid any skin contact due to extreme toxicity
ISOLATION: ERG 151: Isolate spill area at least 25m in all directions; if large spill or fire involved, isolate 800m and consider evacuation
ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO
Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.
=== IC HAZMAT BRIEFING ===
UN 1618 — Lead arsenites
Class: 6 | Placard: Toxic | ERG Guide: 151
Appearance: White to grayish-white powder or crystalline solid. Odorless. Stable at room temperature as a solid.
Water Reactivity: Slightly soluble in water; releases toxic arsenic compounds upon dissolution
Extinguishing: Water spray, dry chemical, CO2; foam not typically required for non-combustible material
PPE: Level A or B required; full-face SCBA, chemical-resistant suit, double gloves; avoid any skin contact due to extreme toxicity
Isolation: ERG 151: Isolate spill area at least 25m in all directions; if large spill or fire involved, isolate 800m and consider evacuation
— Key Hazards —
• Highly toxic, may be fatal if inhaled, ingested or absorbed through skin.
• Avoid any skin contact.
• Fire may produce irritating, corrosive and/or toxic gases.
— First Actions —
• CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper
• Keep unauthorized personnel away.
• Stay upwind, uphill and/or upstream.
• Isolate spill or leak area in all directions for at least 50 meters (150 feet) for liquids and at least 25 meters
SOURCE: allfirefighter.com/hazmat/un/1618 | Always use current ERG + SOP/SOGIC BRIEFING
Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief. Full chemical + response details.
UN1618 Lead arsenites Cls6 ERG151 | ERG 151: Isolate spill area at least 25m in all directions; if large spill or fi | allfirefighter.com/hazmat/un/1618SMS / 160 CHAR
Use for: Quick text to command or incoming units. Fits in a single SMS. Includes link to full page.
⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions.
Page: https://allfirefighter.com/hazmat/un/1618
Advertisement
Frequently Asked Questions about UN 1618
Highly toxic, may be fatal if inhaled, ingested or absorbed through skin. Avoid any skin contact. Fire may produce irritating, corrosive and/or toxic gases. Runoff from fire control or dilution water may be corrosive and/or toxic and cause environmental Non-combustible, substance itself does not burn but may decompose upon heating to produce corrosive Containers may explode when heated. Runoff may pollute waterways.
CALL 911. Then call emergency response telephone number on shipping paper. If shipping paper Keep unauthorized personnel away. Stay upwind, uphill and/or upstream.
Level A or B required; full-face SCBA, chemical-resistant suit, double gloves; avoid any skin contact due to extreme toxicity
Water reactivity: Slightly soluble in water; releases toxic arsenic compounds upon dissolution. Recommended extinguishing: Water spray, dry chemical, CO2; foam not typically required for non-combustible material.
ERG Guide 151 recommendation: ERG 151: Isolate spill area at least 25m in all directions; if large spill or fire involved, isolate 800m and consider evacuation
No. This is a training/quick-reference aid only. Always consult the current ERG Guide 151 and your department SOP/SOG for incident-specific protective actions.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles.
This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.