☣️ UN 1395 • CLASS 4

UN 1395 — Aluminum ferrosilicon powder

Placard: Dangerous When Wet. ERG Guide 139. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1395 is Aluminum ferrosilicon powder, a dangerous-when-wet Class 4 material assigned to ERG Guide 139. Contact with water or moisture can release flammable or toxic gas, creating fire, toxic exposure or pressure hazards.

Hazard overview: UN 1395 presents water-reactive, ignition and reaction-gas hazards. Moisture can generate flammable or toxic gas and heat, so responders should keep the material dry, control runoff and use only compatible dry agents under incident command.

Response guidance: For a UN 1395 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 139. Establish incident command, isolate the area, stay upwind, avoid unnecessary disturbance of powder, piles or damaged packaging, and use only extinguishing agents compatible with the specific material.

Firefighter training notes: Training for UN 1395 should emphasize dangerous-when-wet behavior, reaction gas identification, dry-agent selection and downwind gas control. Common errors include using water or foam directly, entering low areas without monitoring and underestimating re-ignition. Use ERG 139, SDS and hazmat SOP.

Regulatory context: Aluminum ferrosilicon powder is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by formulation, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Aluminum ferrosilicon powder should be stored in tightly closed compatible containers in a cool, dry, well-ventilated area away from water, moisture, acids, oxidizers, heat and ignition sources. Protect containers from damage and keep compatible dry spill-control media available where required.

Advertisement

UN 1395 Quick Details

UN 1395
Product name: Aluminum ferrosilicon powder
DOT Class: 4
Placard type: Dangerous When Wet
ERG Guide: 139 (check current ERG)
Initial isolation: ERG 139: isolate 100m all directions; if fire or water exposure, isolate 800m and evacuate 1600m downwind

Common Hazards of UN 1395

  • DANGEROUS WHEN WET; contact with water or moisture can release flammable or toxic gas.
  • May ignite on contact with water or moist air.
  • Reaction with water may generate heat and pressure.
  • May be ignited by heat, sparks or flames and may re-ignite after apparent extinguishment.
  • Containers may rupture or explode when heated.
  • Runoff or water application may spread contamination and increase gas generation.
  • Avoid low, enclosed or poorly ventilated areas where reaction gases may accumulate.

Chemical Identity & Physical Properties

Gray to dark gray metallic powder with no distinctive odor. Solid at room temperature.

Also known asFerrosilicon aluminum alloy powderAluminum-ferrosilicon powderAl-FeSi powder
AppearanceGray to dark gray metallic powder with no distinctive odor. Solid at room temperature.
Flash PointNot applicable (pyrophoric solid)
Boiling PointNot applicable (decomposes)
Vapor DensityNot applicable (solid)
Water ReactivityReacts with water producing flammable hydrogen gas and toxic fumes; may ignite spontaneously
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1395

Extinguishing Media

Use dry sand, dry chemical, soda ash, dry lime, graphite or approved Class D/dry media only if compatible and directed by incident command. Do not apply water or foam directly because water contact can generate flammable or toxic gas.

PPE Requirements

⚠️ Level B minimum; SCBA required; chemical-resistant gloves and boots; avoid moisture exposure

Use positive-pressure SCBA for any suspected flammable or toxic gas, fire, vapor or confined-space exposure. Chemical-resistant clothing, gloves and eye/face protection should be selected from SDS and incident command; air monitoring is important.

Isolation & Evacuation

ERG 139: isolate 100m all directions; if fire or water exposure, isolate 800m and evacuate 1600m downwind
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 139).

First Actions for a UN 1395 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid low areas where flammable or toxic gas may collect.
  • Do not touch spilled material or damaged containers unless properly trained and equipped.
  • Keep water, foam and moisture away from the released material unless incident command confirms a compatible cooling or control use.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the spill or leak area and expand the perimeter if water contact, fire or gas generation is suspected.
  • Use ERG Guide 139, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 1395 — Aluminum ferrosilicon powder
HAZMAT RADIO NOTE — UN 1395 Product: Aluminum ferrosilicon powder Class 4 / Dangerous When Wet / ERG 139 PPE: Level B minimum; SCBA required; chemical-resistant gloves and boots; avoid moisture exposure ISOLATION: ERG 139: isolate 100m all directions; if fire or water exposure, isolate 800m and evacuate 1600m downwind ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1395 — Aluminum ferrosilicon powder Class: 4 | Placard: Dangerous When Wet | ERG Guide: 139 Appearance: Gray to dark gray metallic powder with no distinctive odor. Solid at room temperature. Water Reactivity: Reacts with water producing flammable hydrogen gas and toxic fumes; may ignite spontaneously Extinguishing: Use dry sand, dry chemical, soda ash, dry lime, graphite or approved Class D/dry media only if compatible and directed by incident command. Do not apply water or foam directly because water contact can generate flammable or toxic gas. PPE: Level B minimum; SCBA required; chemical-resistant gloves and boots; avoid moisture exposure Isolation: ERG 139: isolate 100m all directions; if fire or water exposure, isolate 800m and evacuate 1600m downwind — Key Hazards — • DANGEROUS WHEN WET; contact with water or moisture can release flammable or toxic gas. • May ignite on contact with water or moist air. • Reaction with water may generate heat and pressure. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid low areas where flammable or toxic gas may collect. SOURCE: allfirefighter.com/hazmat/un/aluminum-ferrosilicon-powder-un-1395 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1395 Aluminum ferrosilicon powder Cls4 ERG139 | allfirefighter.com/hazmat/un/aluminum-ferrosilicon-powder-un-1395SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/aluminum-ferrosilicon-powder-un-1395

Related UN Numbers in Class 4

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1395

UN 1395 is Aluminum ferrosilicon powder, a hazardous material assigned to ERG Guide 139.

Yes. It can produce flammable or toxic gas and may ignite when exposed to water or moist air.

ERG Guide 139 applies to UN 1395 for initial isolation, protective actions and first response guidance.

UN 1395 presents water-reactive, ignition and reaction-gas hazards. Moisture can generate flammable or toxic gas and heat, so responders should keep the material dry, control runoff and use only compatible dry agents under incident command.

Use positive-pressure SCBA for any suspected flammable or toxic gas, fire, vapor or confined-space exposure. Chemical-resistant clothing, gloves and eye/face protection should be selected from SDS and incident command; air monitoring is important.

Do not apply water or foam directly unless incident command and product guidance confirm a safe use, because water contact can generate flammable or toxic gas and heat.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.