☣️ UN 1333 • CLASS 4

UN 1333 — Cerium, slabs, ingots or rods

Placard: Flammable Solid. ERG Guide 170. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 1333 is Cerium, slabs, ingots or rods, a Class 4 flammable metal material assigned to ERG Guide 170. Firefighters should think about dust ignition, intense metal fire, re-ignition and incompatible extinguishing agents.

Hazard overview: UN 1333 presents flammable metal and dust hazards. Fine particles or heated metal can ignite, burn intensely and may react dangerously with water or incompatible fire agents, especially if dry or dispersed.

Response guidance: For a UN 1333 incident, responders should verify the product with shipping papers, package markings, SDS and ERG Guide 170. Establish incident command, isolate the area, stay upwind, avoid unnecessary disturbance of powder or damaged packaging, and use only extinguishing agents compatible with the specific material.

Firefighter training notes: Training for UN 1333 should emphasize metal fire behavior, dust cloud prevention, incompatible extinguishing agents, re-ignition, dry-agent application and safe standoff. Common errors include using water or foam on burning metal, disturbing powder and underestimating metal oxide fumes. Use ERG 170, SDS and metal-fire SOP.

Regulatory context: Cerium, slabs, ingots or rods is regulated as a hazardous material for transportation and emergency response purposes. Transportation, workplace exposure, spill reporting, waste handling, storage and environmental requirements may vary by formulation, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, facility documents and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Cerium, slabs, ingots or rods should be stored in compatible containers away from heat, ignition sources, oxidizers, moisture where incompatible and physical damage. Prevent dust release, container damage and contact with incompatible extinguishing agents or water-reactive conditions as described in the SDS.

Advertisement

UN 1333 Quick Details

UN 1333
Product name: Cerium, slabs, ingots or rods
DOT Class: 4
Placard type: Flammable Solid
ERG Guide: 170 (check current ERG)
Initial isolation: ERG 170: Initial isolation 50m in all directions. Protect from moisture and ignition sources.

Common Hazards of UN 1333

  • FLAMMABLE reactive metal; shavings, dust or heated pieces may ignite more readily than solid ingots or rods.
  • Dusts or fine particles may burn rapidly or form explosive mixtures in air.
  • Metal fires can burn with intense heat and may re-ignite after apparent extinguishment.
  • Water contact may react with heated or finely divided cerium and produce flammable hydrogen.
  • Metal oxide fumes from fire may be hazardous to breathe.
  • Containers may rupture or explode when heated.
  • Avoid creating dust clouds or spreading powder during response.

Chemical Identity & Physical Properties

Silvery-gray to iron-gray metallic solid. Soft, malleable metal that tarnishes readily in air. Odorless.

Also known asCerium metalMetallic ceriumCerium ingotsCerium slabs
CAS Number7440-45-1
AppearanceSilvery-gray to iron-gray metallic solid. Soft, malleable metal that tarnishes readily in air. Odorless.
Flash PointNot applicable (pyrophoric metal)
Boiling Point3443C (6229F)
Vapor DensityNot applicable (solid metal)
Water ReactivityReacts with water, especially when finely divided or heated. May ignite spontaneously in moist air.
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 1333

Extinguishing Media

Use Class D dry powder, dry sand, dry salt, graphite or other compatible dry agent as directed by incident command. Do not use water, foam, CO2 or halogenated agents on burning reactive metal.

PPE Requirements

⚠️ Level B minimum with SCBA. Heat-resistant gloves recommended. Face shield for fire conditions.

Use positive-pressure SCBA for fire, smoke or dust exposure. Protective clothing, gloves and eye/face protection should follow SDS and metal-fire SOP; PPE does not protect against violent metal fire, dust explosion or container rupture hazards.

Isolation & Evacuation

ERG 170: Initial isolation 50m in all directions. Protect from moisture and ignition sources.
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 170).

First Actions for a UN 1333 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Eliminate ignition sources if it is safe to do so.
  • Do not create dust clouds or disturb spilled powder unless properly trained and equipped.
  • Keep water, foam, CO2 and halogenated agents away from burning or reactive metal unless incident command confirms compatibility.
  • Use dry Class D agents, dry sand or other compatible dry media when directed by incident command.
  • Isolate the spill or fire area and expand the perimeter if metal powder is burning, dry or dispersed.
  • Use ERG Guide 170, shipping papers, SDS and metal-fire SOP for protective actions and entry decisions.
Advertisement

📋 Copy & Share Field Card

UN 1333 — Cerium, slabs, ingots or rods
HAZMAT RADIO NOTE — UN 1333 Product: Cerium, slabs, ingots or rods Class 4 / Flammable Solid / ERG 170 PPE: Level B minimum with SCBA. Heat-resistant gloves recommended. Face shield for fire conditions. ISOLATION: ERG 170: Initial isolation 50m in all directions. Protect from moisture and ignition sources. ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 1333 — Cerium, slabs, ingots or rods Class: 4 | Placard: Flammable Solid | ERG Guide: 170 Appearance: Silvery-gray to iron-gray metallic solid. Soft, malleable metal that tarnishes readily in air. Odorless. Water Reactivity: Reacts with water, especially when finely divided or heated. May ignite spontaneously in moist air. Extinguishing: Use Class D dry powder, dry sand, dry salt, graphite or other compatible dry agent as directed by incident command. Do not use water, foam, CO2 or halogenated agents on burning reactive metal. PPE: Level B minimum with SCBA. Heat-resistant gloves recommended. Face shield for fire conditions. Isolation: ERG 170: Initial isolation 50m in all directions. Protect from moisture and ignition sources. — Key Hazards — • FLAMMABLE reactive metal; shavings, dust or heated pieces may ignite more readily than solid ingots or rods. • Dusts or fine particles may burn rapidly or form explosive mixtures in air. • Metal fires can burn with intense heat and may re-ignite after apparent extinguishment. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Eliminate ignition sources if it is safe to do so. SOURCE: allfirefighter.com/hazmat/un/cerium-slabs-ingots-or-un-1333 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN1333 Cerium, slabs, ingots or rods Cls4 ERG170 | allfirefighter.com/hazmat/un/cerium-slabs-ingots-or-un-1333SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/cerium-slabs-ingots-or-un-1333

Related UN Numbers in Class 4

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 1333

UN 1333 is Cerium, slabs, ingots or rods, a hazardous material assigned to ERG Guide 170.

Yes. It is a flammable solid, and fine metal particles can burn intensely or form hazardous dust clouds.

ERG Guide 170 applies to UN 1333 for initial isolation, protective actions and first response guidance.

UN 1333 presents flammable metal and dust hazards. Fine particles or heated metal can ignite, burn intensely and may react dangerously with water or incompatible fire agents, especially if dry or dispersed.

Use positive-pressure SCBA for fire, smoke or dust exposure. Protective clothing, gloves and eye/face protection should follow SDS and metal-fire SOP; PPE does not protect against violent metal fire, dust explosion or container rupture hazards.

Use Class D dry powder, dry sand, dry salt, graphite or other compatible dry agent as directed by incident command. Do not use water, foam, CO2 or halogenated agents on burning reactive metal.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.