☣️ UN 2250 • CLASS 6

UN 2250 — Dichlorophenyl isocyanates

Placard: Toxic. ERG Guide 156. Training/quick-reference only — use current ERG + SOP/SOG for incident-specific actions.

🚒☣️
⚠️ This page is a quick-reference aid. For real incidents: stage upwind, isolate, deny entry, request Hazmat early, and consult the current ERG + SOP/SOG.

UN 2250 is Dichlorophenyl isocyanates, a toxic isocyanate liquid assigned to ERG Guide 156. Inhalation can cause respiratory sensitization and water reaction can build pressure.

Hazard overview: TOXIC isocyanate liquid; inhalation of vapor or aerosol may cause severe respiratory sensitization and injury. Combustible material: may burn but does not ignite readily. Reacts with water to release carbon dioxide, heat and toxic/corrosive products; pressure buildup may occur in closed containers.

Response guidance: For a UN 2250 incident, verify the product with shipping papers, container markings, SDS and ERG Guide 156. Establish incident command, isolate the area, stay upwind, control ignition or incompatibility hazards, prevent runoff, dust or vapor spread and base entry/fire-control actions on monitoring and local SOP.

Firefighter training notes: Training for UN 2250 should emphasize isocyanate respiratory sensitization, water reaction/CO2 pressure, vapor monitoring, PPE, decontamination and runoff containment. Use ERG 156, SDS and local SOP.

Regulatory context: Dichlorophenyl isocyanates is regulated as a hazardous material for transportation and emergency response purposes. Storage, workplace exposure, emergency planning, spill reporting, waste handling and environmental requirements vary by exact product, concentration, quantity and jurisdiction. Verify current requirements through shipping papers, SDS, container markings and applicable DOT, OSHA, EPA, NFPA, state or local authority guidance.

Storage & handling: Dichlorophenyl isocyanates should be stored in tightly closed compatible containers in a cool, dry, ventilated area away from water/moisture, amines, alcohols, acids/bases where incompatible and heat. Prevent pressure buildup and humid air exposure.

Advertisement

UN 2250 Quick Details

UN 2250
Product name: Dichlorophenyl isocyanates
DOT Class: 6
Placard type: Toxic
ERG Guide: 156 (check current ERG)
Initial isolation: ERG 156: Small spill isolate 50m all directions; large spill isolate 100m, evacuate 500m downwind if material on fire or involved in fire

Common Hazards of UN 2250

  • TOXIC isocyanate liquid; inhalation of vapor or aerosol may cause severe respiratory sensitization and injury.
  • Combustible material: may burn but does not ignite readily.
  • Reacts with water to release carbon dioxide, heat and toxic/corrosive products; pressure buildup may occur in closed containers.
  • Skin and eye contact may cause irritation, burns or sensitization.
  • Vapors may collect in low or confined areas depending on temperature and formulation.
  • Fire may produce nitrogen oxides, isocyanate vapors, hydrogen cyanide-type products and other toxic gases.
  • Runoff may spread toxic isocyanate contamination.

Chemical Identity & Physical Properties

Clear to pale yellow liquid with a pungent, acrid odor. Combustible liquid at room temperature that may fume in moist air due to moisture reactivity.

Also known asDichlorophenyl isocyanatesDichlorophenylisocyanateDCPIChlorinated phenyl isocyanate
AppearanceClear to pale yellow liquid with a pungent, acrid odor. Combustible liquid at room temperature that may fume in moist air due to moisture reactivity.
Flash Point129C (265F)
Boiling PointApproximately 240-250C (464-482F) with decomposition
Vapor Density6.5-7.0 (heavier than air)
Water ReactivityReacts with water releasing carbon dioxide and forming dichloroaniline derivatives; liberates heat and toxic/corrosive fumes. Do not use water directly on material.
Chemical details are general reference only. Always verify with current SDS, ERG, and SOP/SOG.

Fireground Response Guidance — UN 2250

Extinguishing Media

Use dry chemical, CO2 or alcohol-resistant foam when compatible. Avoid direct water application to the liquid; water may generate carbon dioxide, heat and pressure in closed containers.

PPE Requirements

⚠️ Level B minimum with full-face SCBA required. Chemical-resistant suit for spill response. Avoid all skin contact—causes severe burns and sensitization.

Use positive-pressure SCBA for vapor, aerosol, fire or confined-space exposure. Wear chemical-resistant gloves, boots, eye/face protection and protective clothing selected from SDS; Level A may be needed for heavy vapor or unknown concentrations.

Isolation & Evacuation

ERG 156: Small spill isolate 50m all directions; large spill isolate 100m, evacuate 500m downwind if material on fire or involved in fire
Always confirm protective actions with the current edition of the Emergency Response Guidebook (ERG Guide 156).

First Actions for a UN 2250 Incident

  • CALL 911. Then call the emergency response telephone number on the shipping paper, if available.
  • Keep unauthorized personnel away.
  • Stay upwind, uphill and/or upstream.
  • Avoid breathing vapors, dust, mist, smoke or fumes and avoid skin or eye contact.
  • Avoid unnecessary water contact with released product because pressure and heat can build in closed containers.
  • Do not touch damaged containers or spilled material unless properly trained and wearing appropriate protective equipment.
  • Ventilate closed spaces before entering, but only if properly trained, equipped, monitored and authorized by incident command.
  • Isolate the spill or release area and expand the perimeter for fire involvement, vapor spread, dust generation, water reaction or unknown product identity.
  • Use ERG Guide 156, shipping papers, SDS, air monitoring and incident command for protective actions.
Advertisement

📋 Copy & Share Field Card

UN 2250 — Dichlorophenyl isocyanates
HAZMAT RADIO NOTE — UN 2250 Product: Dichlorophenyl isocyanates Class 6 / Toxic / ERG 156 PPE: Level B minimum with full-face SCBA required. Chemical-resistant suit for spill response. Avoid all skin contact—causes severe burns and sensitization. ISOLATION: ERG 156: Small spill isolate 50m all directions; large spill isolate 100m, evacuate 500m downwind if material on fire or involved in fire ACTION: Stage upwind · Isolate · Deny entry · Request HazmatRADIO

Use for: Quick radio or face-to-face size-up. Short, structured, field-ready.

SMS WhatsApp
=== IC HAZMAT BRIEFING === UN 2250 — Dichlorophenyl isocyanates Class: 6 | Placard: Toxic | ERG Guide: 156 Appearance: Clear to pale yellow liquid with a pungent, acrid odor. Combustible liquid at room temperature that may fume in moist air due to moisture reactivity. Water Reactivity: Reacts with water releasing carbon dioxide and forming dichloroaniline derivatives; liberates heat and toxic/corrosive fumes. Do not use water directly on material. Extinguishing: Use dry chemical, CO2 or alcohol-resistant foam when compatible. Avoid direct water application to the liquid; water may generate carbon dioxide, heat and pressure in closed containers. PPE: Level B minimum with full-face SCBA required. Chemical-resistant suit for spill response. Avoid all skin contact—causes severe burns and sensitization. Isolation: ERG 156: Small spill isolate 50m all directions; large spill isolate 100m, evacuate 500m downwind if material on fire or involved in fire — Key Hazards — • TOXIC isocyanate liquid; inhalation of vapor or aerosol may cause severe respiratory sensitization and injury. • Combustible material: may burn but does not ignite readily. • Reacts with water to release carbon dioxide, heat and toxic/corrosive products; pressure buildup may occur in closed containers. — First Actions — • CALL 911. Then call the emergency response telephone number on the shipping paper, if available. • Keep unauthorized personnel away. • Stay upwind, uphill and/or upstream. • Avoid breathing vapors, dust, mist, smoke or fumes and avoid skin or eye contact. SOURCE: allfirefighter.com/hazmat/un/dichlorophenyl-isocyanates-un-2250 | Always use current ERG + SOP/SOGIC BRIEFING

Use for: Incident command briefing, staging area whiteboard, or pre-entry team brief.

SMS (short)
UN2250 Dichlorophenyl isocyanates Cls6 ERG156 | allfirefighter.com/hazmat/un/dichlorophenyl-isocyanates-un-2250SMS / 160 CHAR

Use for: Quick text to command or incoming units. Fits in a single SMS.

⚠️ Quick-reference only. Always use current ERG + SOP/SOG for incident-specific actions. Page: https://allfirefighter.com/hazmat/un/dichlorophenyl-isocyanates-un-2250

Related UN Numbers in Class 6

Discovery block for training / quick reference. Always consult the current ERG + your SOP/SOG for operations.
Advertisement

Frequently Asked Questions about UN 2250

UN 2250 is Dichlorophenyl isocyanates, a hazardous material assigned to ERG Guide 156.

It is combustible but does not ignite readily; toxic isocyanate exposure is the main hazard.

ERG Guide 156 applies to UN 2250 for initial isolation, protective actions and first response guidance.

TOXIC isocyanate liquid; inhalation of vapor or aerosol may cause severe respiratory sensitization and injury. Combustible material: may burn but does not ignite readily. Reacts with water to release carbon dioxide, heat and toxic/corrosive products; pressure buildup may occur in closed containers.

Use positive-pressure SCBA for vapor, aerosol, fire or confined-space exposure. Wear chemical-resistant gloves, boots, eye/face protection and protective clothing selected from SDS; Level A may be needed for heavy vapor or unknown concentrations.

Water can react with isocyanates to release carbon dioxide and heat, causing pressure buildup in closed containers.
Sources (high level): DOT/PHMSA marking & class concepts + ERG usage principles. This page does not reproduce ERG guide text—always consult the current ERG for incident-specific protective actions.